BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! 

FOLLOW NATIONAL, STATE AND LOCAL CODES. 

READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

  

 
 

 

The SPP-235P Single-phase Submersible Pump Protector is a pump monitor designed to protect 

single-phase pumps from dry-well, dead-head, rapid-cycle, jammed impeller, and over/under 

voltage conditions.  The Submersible Pump Protector SPP-235P protects 5 to 15 HP, 230VAC 

pumps.  Typical applications include submersible pumps, centrifugal pumps, cooling pumps, 

environmental pumps, residential water wells, commercial water wells, irrigation wells, and golf 

course or other sprinkler equipment.   

 
 

 

CONNECTIONS 

 

NOTE: Use with UL/CSA listed overload or impedance protected pumps or motors only. 

 

1. 

Mount the Submersible Pump Protector Model SPP-235P in a convenient location in or near 
the pump control box. If the location is wet or dusty, a NEMA 3R, 4, or 12 enclosure should be 
used.  The Submersible Pump Protector must be protected by a fuse or circuit breaker. 

2. 

Connect a current transformer (CT) to the SPP’s terminals marked CT1 and CT2.  (see Table 

 for proper CT sizing). 

1

 

3. 

Connect the SPP’s terminals marked ‘L1’, ‘L2 IN’ and ‘L2 OUT’. 

4. 

Refer to the appropriate wiring diagram for your specific application. 

  Typical wiring diagram  

– Figure 1 

  Standard 3-wire control box  

– Figure 2 

  Deluxe control box  

 

– Figure 3 

 
 

NOTE: One line from the fused disconnect must pass through the current transformer. 
 
NOTE: The Submersible Pump Protector will not function without an external current 
transformer.  A UL Listed current transformer must be selected based on Table 1.   
 
NOTE: The Submersible Pump Protector may not detect a dead-head (blocked pipe) 
condition on applications where the pump is undersized for a given motor or flow restrictors 

re used on high stage pumps or low yield wells.   

a

 
 
 

*** WARNING *** 

 

PROPER OPERATION REQUIRES FIELD CALIBRATION 

 

 

 

Содержание Pentek SPP-235P

Страница 1: ...INSTALLATION INSTRUCTIONS Submersible Pump Protector MODEL SPP 235P II_SPP 235P_A1 293 Wright Street Delavan WI 53115 866 9 PENTEK...

Страница 2: ...ontrol box If the location is wet or dusty a NEMA 3R 4 or 12 enclosure should be used The Submersible Pump Protector must be protected by a fuse or circuit breaker 2 Connect a current transformer CT t...

Страница 3: ...Size Current CT 5 7 HP 27 5 42 1 50 5 10 HP 51 75 5 15 HP 75 100 5 TABLE 1 Current Transformer Selection FIGURE NO 1 Typical Wiring Diagram 3...

Страница 4: ...4...

Страница 5: ...he RESTART DELAY CALIBRATION knob to CAL while pumping Wait for the pump to turn off approximately 10 seconds then adjust the RESTART DELAY CALIBRATION knob to the desired setting SENSITIVITY The Subm...

Страница 6: ...60 second period The Submersible Pump Protector is capable of detecting a rapid cycle condition whether a control device such as a pressure switch is installed before or after it Upon detecting eithe...

Страница 7: ...Submersible Pump Protector remove and re apply power Note Protection against rapid cycling of a control device installed after the Submersible Pump Protector is always enabled Disabling line side det...

Страница 8: ...e to a dry run or dead head condition The unit is timing through the restart delay and will try to restart Check for restricted flow or inadequate supply of liquid Off Blinking OVERCURRENT The Submers...

Страница 9: ...PHYSICAL DIMENSIONS 4 05 102 87 5 26 133 60 4 50 114 30 375 9 53 2 93 74 42 FRONT VIEW 2 17 55 12 2 90 73 66 BOTTOM VIEW 9...

Страница 10: ...age 230VAC Load Range 5 to 15hp external current transformer required Frequency 50 60 Hz note 50Hz will increase all delay timers by 20 Output Characteristics Output Contact Rating SPST 720VA 240VAC G...

Страница 11: ...11 NOTES...

Страница 12: ...ure provided such goods have not been subjected to misapplication misuse negligence or repairs by unauthorized persons This Warranty does not apply to any faulty performance caused by improper voltage...

Отзывы: