AquaLumin
®
II - Nicheless Light Installation Guide
AquaLumin
®
II - Nicheless Light Installation Guide
6
8.
Cut the cord at the junction box, leaving at least six (6) inches of cord to make
connections.
9.
Strip 6 inches of the outer cord jacket to expose the three insulated wires. Be careful not
to damage the insulation on the three inner wires.
10.
Connect cord to electrical wires at Junction Box, be careful to not pull the three (3) in. of
slack cord at the light through the conduit when connecting the wires. All wiring should be
connected to a Class A Ground Fault Circuit Interrupter (GFCI), in accordance with
electrical codes, see Section 1.A.1.a on page 3.
11.
Connect all three wires to the corresponding circuit wires in the junction box and secure
the junction box cover in place.
12.
Before operating the light for more than 10 seconds, fill pool until the Nicheless Light is
completely submerged in water. To check for proper operation, turn on main switch or
circuit breaker, as well as the switch which operates the Nicheless Light.
Figure 4.
Section 1: Installing a mounting bracket and light fixture during new vinyl
pool construction
(Continued)
WARNING:
Never operate this Nicheless Light for more than 10 seconds unless
it is totally submerged in water. Without total submersion, the light assembly will get
extremely hot, which may result in serious burns or in breakage of the lamp or lens.
This may result in serious injury to pool users, installer, or bystanders, or in damage
to property.
WARNING:
Use only the special stainless steel captive screw (see
Light
Assembly Parts
, item 4, on page 14) provided with this Nicheless Light. This screw
mounts and electrically grounds the housing securely to the Nicheless fixture. Failure
to use the screw provided could create an electrical hazard which could result in death
or serious injury to pool users, installers or others due to electrical shock.
C. Winterizing:
Light should be left in place for winterization.
11
8.
To remove the lamp:
a.
Place the light in front of you so that the captive screw hole is at the top, and the lamp
is in a horizontal position.
b.
Grasp the lamp on the right side.
c.
Push the lamp to the left, compressing the spring in the spring loaded lamp socket,
until the right side of the lamp comes free from the fixed socket end.
9.
Install the new lamp by performing step 8, a through c, in reverse order.
NOTE:
Select
proper lamp for either 12 volt or 120 volt applications. Take care not to touch the halogen
bulb with bare hands.
10. Never reuse the old lens gasket when reassembling the light. Replace the old lens gasket
with a new genuine Pentair Water AquaLumin II lens gasket (P/N 619599), provided in the
Bulb Replacement Kit. The orientation of the tabs on the lens gasket is not important.
11. Replace the eight (8) sealing screws left in the face ring with eight (8) new sealing screws
provided in the Bulb Replacement Kit.
NOTE:
Install the new sealing screws in the same
location as those removed, leaving "TOP" (12 o'clock) and "BOTTOM" (6 o'clock) open.
12. Reinstall the lens gasket, lens and plastic face ring. While replacing the lens, be sure the
tabs around the perimeter of the lens gasket are not under the flange of the lens. Orientate
the lens so that the word "TOP" is aligned with the captive screw hole. When reinstalling
the plastic face ring, align the heads of the sealing screws with the large circular holes of
the keyway slots. Press down on the plastic face ring and rotate in the clockwise direction
until the sealing screws interfere with the housing (at the end of the slot). Orientate the
plastic face ring so that the words "MADE IN USA" are aligned with the captive screw hole
on the housing as well as the word "TOP" on the lens.
WARNING:
Be sure power is OFF before installing or removing lamp. Allow lamp to cool
before relamping. This light fixture uses a Halogen Quartz lamp. Do Not touch lamp with bare
hands, this may severely reduce its life. Use the plastic furnished with the replacement lamp to
eliminate finger prints from getting on lamp.
Section 3: Replacing a lamp only
(Continued)
WARNING
Always install a new lens gasket, part number 619599, whenever
reassembling the light. Failure to do so may permit water to leak into the assembly which
could cause; (a) an electrical hazard resulting in death or serious injury to pool users,
installer, or others due to electrical shock, or (b) breakage of the lamp or lens, which
likewise could result in serious injury to pool user, installers, or bystanders, or in damage
to property.