Section 1: Installing a mounting bracket and light fixture during new vinyl
pool construction
A. Preparatory steps which must be completed by the electrician before light is installed,
see Figure 1.
1.
Be sure the electrical system of the pool conforms with the requirements of the current
National Electrical Code (NEC) and all local codes and ordinances. A licensed or certified
electrician must install the electrical system to meet or exceed those requirements before
the Nicheless Light is installed. Some of the requirements of the NEC are listed below.
a.
The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI), and have an
appropriately rated
circuit breaker.
b.
The junction box (or, for
12 volt models, the low
voltage transformer) is
located at least 12
inches above water
level, and at least 48
inches from the edge of
the pool, see Figure 1.
c.
The light fixture and all
metal items within five
(5) feet of the pool must
be properly electrically
bonded.
18" MIN. FROM WATER
TO TOP OF FACE RING
12" MIN. FROM BOTTOM
OF JUNCTION BOX
OR LOW VOLTAGE
TRANSFORMER TO WATER LINE
TO EXISTING
BONDING
CONNECTOR
WATER
LEVEL
TOP OF FACE RING
CORRESPONDS
TO CENTER OF
MOUNTING HUB
RIGID CONDUIT
48"
MIN.
TO GFCI, CIRCUIT
BREAKER AND
POWER SOURCE
PILOT SCREW AT TOP
MOUNTING HUB
Figure 1
D A N G E R !
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
This Nicheless light fixture must be installed by a licensed or certified electrician or
a qualified pool serviceman in accordance with the National Electrical Code and all
applicable local codes and ordinances. Improper installation will create an electrical
hazard which could result in death or serious injury to pool users, installers or
others due to electrical shock and may also cause damage to property. Always
disconnect power to the pool light at the circuit breaker before servicing the light.
Failure to do so could result in death or serious injury to serviceman, pool users or
others due to electrical shock.
14
Light Assembly Parts
1
2
3
5
6
4
1
619601
Face ring (white)
619632
Face ring (black)
2
619797
Lens
3
619599
Lens gasket
4
78889900 Captive screw
5*
619584
Halogen lamp 12 volt /100 watt
619484
Halogen lamp 120 volt / 250 watt
6
619792
Sealing screws (10 req.)
600140
Kwik change lens set (4)
(not shown)
Part
Item
Number Description
AquaLumin II Replacement Parts
Note: (*) Sold in Bulb Replacement Kits 600139
and 600138.