Rev. E
11-5-07
P/N 472128
17
Installation (contd.)
NOTE:
When connecting a remote control to the MiniMax
®
CH, you must install the low voltage
thermostat wires in separate conduit from
ANY
line voltage wires. Failure to follow these
instructions will cause the thermostat relay to react erratically.
.
Figure 19.
ELECTRICAL
MiniMax
®
CH Millivolt Wiring Diagram
WHT
GAS VALVE
ORN
WHT
HI-LIMIT
OFF
SPA
WHT
WHT
SHUT-OFF
SAFETY
SWITCH
PRESS
WHT
POOL
PILOT
GENERATOR
THERMAL
CUT-OFF
TH
PP
TH/PP
POT 1
THERMOSTAT BOARD
POT 2
TH/PP
PP
POT
SENSOR
SEN
TH
WHT
MINIMAX
®
WIRING DIAGRAM (MILLIVOLT) DUAL THERM
(HONEYWELL ELECTRONIC)
IF ORIGINAL FACTORY WIRING MUST BE REPLACED, INSTALLER MUST SUPPLY UL OR CSA (IF CANADA)
APPROVED WIRE, 18 GAUGE, 600V, 105 C˚ TEMPERATURE RATING. THERMAL FUSE WIRING MUST BE
REPLACED WITH UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 125 C˚ TEMPERATURE RATING.
INTERCONNECTING WIRING TO APPLIANCE MUST CONFORM TO THE NATIONAL ELECTRICAL CODE OR
SUPERCEDING LOCAL (WIRING) CODES.