background image

IntelliFlo VF Installation and User’s Guide

© 2010 Pentair Water Pool and Spa, Inc. All rights reserved 

This document is subject to change without notice

1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000

IntelliFlo®, and the Pentair Water Pool and Spa® are trademarks and/or registered trademarks of Pentair 
Water Pool and Spa, Inc. and/or its affi liated companies in the United States and/or other counties. Unless 
noted, names and brands of others that may be used in this document are not used to indicate an affi liation 
or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa, Inc. 
Those names and brands may be the trademarks or registered trademarks of those parties or others.

P/N 357220

 Rev A  01-12- 2010

Declaration of Conformity

We declare, under our sole responsibility, that the product identifi ed in this declaration, and 
to which this declaration relates, are in conformity with the protection requirements of Council 
Directive 98/37/EEG

Standard EN60335-1, EN50178, EN61800-5-1

Standard EN61800-3, EN61000-6-2, EN61000-6-4

Manufacturer:  Pentair Water Pool and Spa, Inc.
 

1620 Hawkins Ave, Sanford, NC 27330

 

10951 West Los Angeles Ave, Moorpark, CA 93021

Customer Support

Herentals, Belgium (8:00 to 17:00)

Phone: +32(0).14.25.99.11

Website: www.pentairpooleurope.com

Protected by U.S. Patents Pending

Содержание IntelliFlo VF

Страница 1: ...IntelliFlo VF IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation and User s Guide Variable Flow Pump ...

Страница 2: ...tween the proprietors of these names and brands and Pentair Water Pool and Spa Inc Those names and brands may be the trademarks or registered trademarks of those parties or others P N 357220 Rev A 01 12 2010 Declaration of Conformity We declare under our sole responsibility that the product identified in this declaration and to which this declaration relates are in conformity with the protection r...

Страница 3: ... Modes 13 Manual Mode 13 Metering the System 13 Manual RPM Mode 14 Manual Flow Mode 15 To adjust the Speed and Flow 15 Backwash Mode 17 Vacuum Mode 18 Filter Mode 19 Feature 1 2 Mode 20 External Control Mode 20 IntelliFlo With IntelliComm Communication Center 20 Menus 21 IntelliFlo Menus 22 Pool Data Menu 23 Units Menu 24 Priming Menu 24 Filter Menu 26 Filter Cycle Settings 29 Clean Filter Pressur...

Страница 4: ...ion and Removal 51 Installing the IntelliFlo 51 Location 51 Piping 51 Check Valves 51 Wiring the IntelliFlo 52 Pump Disassembly 54 Pump Reassembly Seal Replacement 55 Shaft Seal Replacement 55 Drive Assembly Removal and Installation 56 Illustrated Parts List 57 Replacement Parts 57 IntelliFlo Pump Dimensions 58 Intelliflo Performance Curve 58 IntelliFlo Electrical Specifications 58 Section 6 Troub...

Страница 5: ...mming Pools Wading Pools Spas Hot Tubs and Catch Basins If suction outlets are not used additional entrapment avoidance measures as described in the CPSC Guidelines or ANSI IAF 7 should be employed The covers used on suction outlets should be approved and listed as conforming to the currently published edition of ANSI ASME A112 19 8 Standard covering Suction Fittings for Use in Swimming Pools Wadi...

Страница 6: ... unit WARNING When setting up pool water turnovers or flow rates the operator must consider local codes governing turnover as well as disinfectant feed ratios CAUTION Install the pump a minimum of five 5 feet 1 52 m from the inside wall of the pool and spa Canadian installations require a minimum of three 3 meters from pool water CAUTION A No 8 AWG or larger conductor must be wired to the motor bo...

Страница 7: ... applications NOTE If required by local building codes the pump is to be supplied by an isolating transformer or supplied through a residual current device RCD having a residual operating current not exceeding 30mA NOTE Use only RCD GFCI suitable for protecting equipment with a DC current content in the fault current These instructions contain information for a variety of pump models and therefore...

Страница 8: ...iFlo can reduce energy cost by as much as 90 based on a pool size of up to 55 m3 15 000 US gallons one turn per day with a 24 hour cycle IntelliFlo constantly monitors water flow and electrical current to ensure that the filtration system is operating at peak efficiency This can result in maximum energy efficiency savings never before possible up to 90 over conventional pumps The system protects a...

Страница 9: ...n quality concept Ultra energy efficient TEFC Square Flange Motor highly insulated motor Compatibility with most cleaning systems filters and jet action spas an evolutive product 16 button LCD control panel Drive assembly features permanent magnet synchronous motor state of art motor Heavy duty durable construction designed for long life Internal 24 hour clock for setting controlled on off times f...

Страница 10: ...gh efficiency less motor stress Same technology as deployed in hybrid electric vehicles proven technology Designed to withstand outdoor environment a robust product Totally Enclosed Fan Cooled no water or particles can infiltrate Three phase motor 56 Square Flange Six Pole smooth run mode Low noise what a comfort Drive assembly and electronics enclosure IntelliFlo Motor Assembly Motor fan cover Op...

Страница 11: ... Backwash and Rinse Informs the user when and how to backwash filter media Vacuum Can be preset using duration and flow parameters to save energy Filter Allows pump to run at peak efficiency saving users up to 90 in energy cost based on a pool size up to 55 m3 15 000 US gallons one turn per day with a 24 hour cycle Feature Ten feature modes can be programmed to control filtration duration start an...

Страница 12: ...ED 3 Starts Backwash mode The LED is on when Backwash mode is active Manual button LED 4 Starts Manual mode The LED is on when Manual mode is active Select button 5 Displays available menu items or enters edit mode for changing a value on line two of the display Escape button 6 Moves to next level up in the menu structure and or stops editing the current setting Menu button 7 Accesses the menu ite...

Страница 13: ... is active Feature 2 button 11 Starts Feature 2 mode The LED is lit when mode is active Start Stop button 12 Start or Stop the pump When the LED is lit it indicates that the pump is currently running or in a mode to start automatically Reset button Reset alarm or alert 13 LEDs On This green power LED is on when IntelliFlo is powered on Warning This LED is on if a warning condition is present Alarm...

Страница 14: ...igit 6 When the desired value is displayed press the Enter button to save the changes Press the Escape button to exit edit mode without saving 7 Use the Up and Down arrows to scroll to Max Priming Time or System Priming Time Press the Select button to select it 8 To change the Max Priming Time setting press the Left and Right arrows to select which digit to modify Press the Up and Down arrows to c...

Страница 15: ...iFlo by remote control IntelliFlo Menu Button Use the Menu button to access the settings for the above modes See page 21 for more information on the Menu button Operating Modes Note If the pool system uses a filter always monitor pressure at the filter when changing the speed RPM or flow m3 h from IntelliFlo Manual Mode Metering the System The first step in programming and operating the IntelliFlo...

Страница 16: ...r of the display indicating that the pump is in Manual RPM Mode Use the 3 Up and Down arrow buttons to view the screens below POWER Watts Displays power to the motor shaft in continuous watts ACTUAL SPEED RPM Displays pump speed in RPM FLOW m3 h Displays commanded flow Will read 0 unless a value is programmed in the Set FLOW screen See To Change the Speed and Flow on the following page As long as ...

Страница 17: ...TUAL SPEED RPM Displays pump speed in RPM FLOW m3 h Displays actual flow as long as the IntelliFlo is in Manual Flow Mode Set SPEED RPM Allows you to set IntelliFlo to run at a continuous pump speed Set FLOW m3 h Allows you to set IntelliFlo in Manual Flow Mode to allow the pump to change speed to manage the flow rate based on system changes Note IntelliFlo s sensors with the exception of the flow...

Страница 18: ...op IntelliFlo press the Start Stop button LED is off Stopped appears in the display Note While IntelliFlo is running in Manual mode you can view the current power consumption and what actual speed is being used Change Flow and Speed settings while the IntelliFlo is running 7 To change the flow and speed settings on the fly while the pump is running simply repeat steps 3 through 5 If Set SPEED is c...

Страница 19: ... to reset the clean filter status Then run the pump in filter mode Note IntelliFlo will ramp up to full speed if necessary to achieve the commanded flow Be sure that the system can withstand the resultant pressures A complete backwashing cycle includes a backwash phase and a rinse phase and is accomplished in Backwash Mode At a press of the Backwash button IntelliFlo will run in this mode at the f...

Страница 20: ...ilter setup menu See To set the Clean Filter Pressure on page 26 Upon completion of the backwashing and rinse cycles the backwash valve on 6 the filter should be returned to the Filter position Vacuum Mode Vacuum Mode is intended exclusively for manual pool cleaning and like Feature 1 2 is designed for on demand operation The Vacuum settings menu is used to set the parameters for VacuumMode Flow r...

Страница 21: ... Filter Mode setup Ensure that the green power LED is on 1 Press the 2 Filter button Press the Start Stop button FILTER will appear in the top left corner of the display indicating that the pump is in Filter Mode Use the 3 Up and Down arrow buttons to view the screens below POWER Watts Displays power to the motor shaft in continuous watts ACTUAL SPEED RPM Displays pump speed in RPM FLOW m3 h Displ...

Страница 22: ...ated with the flow setting of 12m3 h and the time duration setting of 1 minute 0 01 External Control Mode IntelliFlo With IntelliComm Communication Center The IntelliFlo can be connected to the Pentair IntelliComm Communication Center via an optional communications cable P N 350122 The IntelliComm is equipped with four pairs of input terminal connections which can be connected to IntelliFlo s Prog...

Страница 23: ...lliComm Terminal number Terminal name Voltage Maximum current Phase type Frequency 1 2 Power supply 100 240 VAC 100 mA 1 Input 50 60 Hz 3 4 Program 1 15 240 VAC or 15 100 VDC 1 mA 1 Input 50 60 Hz 5 6 Program 2 15 240 VAC or 15 100 VDC 1 mA 1 Input 50 60 Hz 7 8 Program 3 15 240 VAC or 15 100 VDC 1 mA 1 Input 50 60 Hz 9 10 Program 4 15 240 VAC or 15 100 VDC 1 mA 1 Input 50 60 Hz 11 12 RS 485 Data Y...

Страница 24: ...isabled Enabled Features 6 Features 7 Set Flow 4 29m 3 h Set StartTime hr mm Set StopTime hr mm Activation Disabled Enabled Set Flow 4 29m 3 h Set StartTime hr mm Set StopTime hr mm Activation Disabled Enabled Features 8 Features 9 Set Flow 4 29m 3 h Set StartTime hr mm Set StopTime hr mm Activation Disabled Enabled Set Flow 4 29m 3 h Set StartTime hr mm Set StopTime hr mm Activation Disabled Enab...

Страница 25: ...ect it To change the setting press the Left and Right arrows to select which digit to modify then use the Up and Down arrows to change the selected digit When you are done press the Enter button to save the changes To cancel any changes press the Escape button to exit edit mode without saving c To enter the pump volume pool size Use the Up and Down arrow buttons to scroll to the Pool Volume settin...

Страница 26: ...enu item Press the Select button to select it a To choose the Flow Unit Use the Up and Down arrow buttons to scroll to the Flow Unit setting Press the Select button to select it Use the Up and Down arrow buttons to choose between cubic meters m3 h or gallons per minute US GPM then press Enter to select the choice b To choose the Time Unit Use the Up and Down arrow buttons to scroll to the Time set...

Страница 27: ... This flow is system dependent and may require iteration During priming the flow will never exceed the maximum priming flow value set in this step however it is common for the pump to ramp up and down quickly while priming Always maintain as low a flow rate as possible for cost savings and safety b To set the Max Priming Time Use the Up and Down arrow buttons to scroll to the Max Priming Time sett...

Страница 28: ...se the Up and Down arrows to change the selected digit 5 When you are done press the Enter button to save the changes To cancel any changes press the Escape button to exit edit mode without saving Filter Menu IntelliFlo will calculate the required flow rate based on pool size pool turns per day cycles per day and schedule to control the pump motor speed and keep a constant flow The filter mode can...

Страница 29: ...o find the Turnovers Per Day setting Press the Select button to select it To change the setting see step 4 below You can set up to eight turns per day Default 1 It is recommended that one turn per day for energy conservation and requirements be performed for most common residential pools Refer to sanitizer recommendation for additional information c To set the number of Cycles Per Day Use the Up a...

Страница 30: ...y setting only one of the four available cycles will read Enabled on the IntelliFlo Operator Control Panel See Filter Cycle Settings table on the following page On the next example the IntelliFlo Control Panel shows a Cycle 1 Start time of 8 00 and a Cycle 1 Stop time of 10 00 indicating a cycle of 2 hours Note that the Cycle 2 Start time of 10 15 reads Enabled because two 2 cycles are entered in ...

Страница 31: ...00 12 59 HH MM am pm Default 21 00 Stop time for cycle 1 if start and stop is the same time the IntelliFlo will run 24 7 Start Cycle 2 1 00 12 59 HH MM am pm Default 21 10 Start time for cycle 2 If Cycles per day is below 2 Disabled will be displayed Stop Cycle 2 1 00 12 59 HH MM am pm Default 21 20 Stop time for cycle 2 If Cycles per day is below 2 Disabled will be displayed Start Cycle 3 1 00 12...

Страница 32: ...pressure The Clean Filter Pressure is set to 0 6 bar Alert Status Once the Alert is triggered the yellow warning LED is lit and Alert is displayed on the screen At this point IntelliFlo will stop managing flow and will adjust speed to maintain 0 6 bar of head pressure Note the following The clean filter pressure has reached 100 See Filter Mode on p 14 and To set the Clean Filter Pressure on p 22 I...

Страница 33: ...med to perform 1 Turnover with a start time of 1 00 and a stop time of 11 00 InterlliFlo calculates the flow rate to achieve this at 8 m3 h 8 m3 h x 10 hours 80 m3 Feature 3 is programmed to start at 4 00 and run at 15 m3 h for 4 hours stopping at 8 00 15 m3 h x 4 hours 60 m3 h The filter cycle begins at 1 00 as scheduled and runs at a rate of 8 m3 h until 4 00 At that time Feature 3 overrides Fil...

Страница 34: ...w The flow that the unit can provide is limited by the installed plumbing If more flow is demanded than the IntelliFlo can provide it will ramp to full speed and create pressure The following example shows a ramp as flow increases from 10 to 17 m3 h Time Speed 10 m3 h Valve is moved 17 m3 h Ramps in Speed Quickly Series of small slow ramps Power and RPM stabilize and required flow is attained 1 2 ...

Страница 35: ...et Time is displayed a To set the system clock Press the Select button to select the Set Time setting b To set the LCD backlight contrast of the control panel display Use the Up and Down arrow buttons to scroll to the Contrast Level setting Press the Select button to select it Default 5 4 To change the setting press the Left and Right arrow buttons to select which digit to modify then use the Up a...

Страница 36: ...art Stop button to stop the backwashing operation already in progress For more information on Feature 1 2 see page 20 Feature 3 9 Feature 3 through Feature 9 are designed for pre programmed operation of water features at fixed flow rates Feature 3 9 allow you to set a feature s flow rate as well as Start and Stop times for the feature The Start and Stop times for Features 3 9 cannot overlap Featur...

Страница 37: ...ime or period in which IntelliFlo will alternate between these speeds Also unlike the M O Flo feature which can operate only during filter cycles set in Filter Mode the Wave Feature must be linked to any of Features 1 9 and operates only in conjunction with those features Example You have installed laminar jets in your pool In the Wave setting you enter a maximum pump speed of 2400 Rotations Per M...

Страница 38: ...e the Pulse feature must be linked to any of Features 1 9 and operates only in conjunction with those features Example You have decided to use the Pulse feature to operate the laminar jets described in the Wave feature example above In the Wave setting you enter a maximum pump speed of 2400 Rotations Per Minute RPM a minimum pump speed of 1000 RPM and a period of three seconds 03 and you link the ...

Страница 39: ... 07 40 Sets start time for feature 8 F8 Stop time 00 00 AM 23 59 Default 07 50 Sets stop time for feature 8 F9 Start time 00 00 AM 23 59 Default 08 00 Sets start time for feature 9 F9 Stop time 00 00 AM 23 59 Default 08 10 Sets stop time for feature 9 M O Flo Set Run time 1 59 minutes or 00 01 00 59 Default 00 01 Sets the duration of time over which the M O Flo feature will operate the pump at the...

Страница 40: ...ure 1 or 2 Press the Select button to access the Feature 1 2 Set Flow setting Default 12m3 h To change the setting see step 4 below b To set the duration for Feature 1 or 2 Use the Up and Down arrow buttons to scroll to the Time Duration setting Press the Select button to access it Default 00 01 To change the setting see step 4 below 4 To change a setting press the Left and Right arrows to select ...

Страница 41: ...Down arrow buttons to toggle between the Disabled and Enabled options Press the Select button to select one Go to step 5 below b To set the flow for Feature 3 9 Use the Up and Down arrow buttons to scroll to the Set Flow setting Press the Select button to access it Default 12m3 h To change the setting see step 4 below c To set the start time for Feature 3 9 Use the Up and Down arrow buttons to scr...

Страница 42: ...selected in the Feature 3 9 Activation setting Feature 3 9 will start and stop at the times programmed in the Feature 3 9 settings menu whenever IntelliFlo is in Filter Mode If Disabled is selected in the Activation setting IntelliFlo will not run Feature 3 9 The parameters you program for features Feature 3 9 supercede the filter cycle parameters you programmed for Filter Mode in the Filter setti...

Страница 43: ...ns Press the Select button to select one Go to step 5 below b To set the flow for the M O Flo feature Use the Up and Down arrow buttons to scroll to the Set Flow setting Press the Select button to access it Default 12m3 h To change the setting see step 4 below c To set the run time for the M O Flo feature Use the Up and Down arrow buttons to scroll to the Set Run Time setting Press the Select butt...

Страница 44: ...e Up and Down arrow buttons to scroll to the Wave or Pulse menu item Press the Select button to select it a To choose whether the Wave or Pulse feature will be Disabled or Enabled Press the Select button to access the Activation setting Default Disabled To change the setting use the up Up and Down arrow buttons to toggle between the Disabled and Enabled options Press the Select button to select on...

Страница 45: ...on you programmed for that feature By using the Up and Down arrow buttons you can switch between screens displaying current flow power usage in Watts W and pump speed in RPM If the Wave or Pulse feature is linked to Feature 3 9 then the feature functions as part of the filter cyles programmed in the Filter settings menu and IntelliFlo must be in Filter Mode for Wave or Pulse to operate IntelliFlo ...

Страница 46: ...d Down arrow buttons to scroll to the desired program Program 1 4 and press the Select button to select it MENU 12 00 Ext Ctrl Ext Ctrl 12 07 Program 1 Ext Ctrl 12 08 Program 2 Ext Ctrl 12 10 Program 3 Ext Ctrl 12 11 Program 4 a To choose whether the program will be Disabled or Enabled Press the Select button to access the Activation setting Default Enabled To change the setting use the up Up and ...

Страница 47: ...splayed 3 Use the Up and Down arrow buttons to scroll to the Backwash menu item Press the Select button to select it a To set the Backwash flow rate Press the Select button to access the Backwash Flow setting Default 14m3 h To change the setting go to step 4 below b To set the Backwash duration Use the Up and Down arrow buttons to scroll to the Backwash Duration setting Press the Select button to ...

Страница 48: ...etting Default 12 m3 h To change the setting see step 4 below b To set the duration Vacuum Mode Use the Up and Down arrow buttons to scroll to the Vacuum Duration setting Press the Select button to access it Default 1 minute or 00 01 To change the setting see step 4 below Vacuum 12 15 12m h VacuumFlow VACUUM 12 15 0 01 VACUUMDURATION 4 To change a setting press the Left and Right arrows to select ...

Страница 49: ...jury make sure the suction and discharge valves are open and that the strainer pot is cool to the touch then open with extreme caution CAUTION To prevent damage to the pump and filter and for proper operation of the system clean pump strainer and skimmer baskets regularly Servicing the Pump Strainer Basket If the IntelliFlo pump is installed below the water level of the pool close the return and s...

Страница 50: ... Shade the motor and controller from the sun Any enclosure must be well ventilated to prevent overheating Particular attention should be paid to the motor fan cover and the cooling fins between the drive and the motor Provide ample cross ventilation 2 Protect against dirt Protect from any foreign matter or splashing water Do not store or spill pool chemicals near the motor Avoid sweeping or stirri...

Страница 51: ...rime Winterizing The IntelliFlo s internal anti freeze protection is disabled when connected to an IntelliTouch Freeze protection is provided by selecting YES at the ON WITH FREEZE portion of the IntelliTouch s appropriate circuit function menu To re enable the IntelliFlo s internal anti freeze protection the power to the drive must be cycled off then back on 1 If the air temperature drops below 3...

Страница 52: ...eed then press the Select button to edit the setting 7 Adjust speed as necessary Press the Left and Right arrows to select which digit to modify then use the Up and Down arrows to change the speed Press the Enter button to save the changes To cancel any changes press the Escape button to exit edit mode without saving 9 Press the Start Stop button to start the pump 10 When water comes out of the ai...

Страница 53: ... 5 sprinklers etc For hot tubs and spas do not install within an outer enclosure or beneath the skirt of a hot tub or spa 6 Install the pump with a rear clearance of at least 15 cm or 6 inches so that the motor can be removed 7 easily for maintenance and repair Piping For improved pool plumbing it is recommended to use a larger pipe size When installing the inlet and outlet fittings male adaptors ...

Страница 54: ...G or larger copper conductor Run a wire from the external bonding lug to the pool bonding structure as shown below 8 Permanently connect the pump to a circuit breaker two pole timer or relay in an automation controller such as IntelliComm The drive must be powered up to receive and respond to the RS 485 serial communication from the automation system Be sure that no other lights or appliances are ...

Страница 55: ...communication from the automation system Be sure that no other lights or appliances are on the same circuit The IntelliFlo pump must be installed with a switch to ensure all pole disconnection from the supply mains in accordance with the Wiring Rules The switch shall be directly connected to the supply terminals and shall have a contact separation in all poles providing full disconnection under ov...

Страница 56: ...haft seal faces seal will leak if faces are damaged All moving parts are located in the rear sub assembly of the IntelliFlo pump Tools required 3 32 inch Allen head wrench inch open end wrench 9 16 inch open end wrench Flat blade screwdriver To remove and repair the pump mechanical seal perform the following procedures Switch off the pump circuit breaker at the main panel 1 Disconnect the communic...

Страница 57: ...Remount the seal plate to the motor 3 Grease the motor shaft thread and screw impeller onto the motor shaft 4 Screw in the impeller lock screw counterclockwise to tighten 5 Remount the diffuser onto the seal plate Make sure the plastic pins and holding screw inserts are aligned 6 Grease the diffuser O ring and seal plate gasket prior to reassembly 7 Grease the bolt threads assemble the motor sub a...

Страница 58: ...ot to remove the gasket between the drive and motor it is critical in keeping moisture out of the drive and motor Replace the gasket if damaged Do not reassemble with a damaged or missing gasket To install the IntelliFlo drive assembly onto the motor assembly 1 Make sure all electrical breakers and switches are turned off before removing the drive 2 Ensure that the gasket between the drive and mot...

Страница 59: ...0 SCREW SET 4 40 X 1 1 8 WFE SCKT CAP 18 8 s s QTY 2 14 072183 WASHER FLAT X 5 8 20 GA THICK 18 8 s s QTY 2 Item No Part No Description 15 072184 WASHER 3 8 ID X 7 8 OD 05 THICK 18 8 s s QTY 6 16 072928 DIFFUSER ASSEMBLY WFE 12 17 073131 IMPELLER WFE 12 1000 SER 18 075713 RUBBER WASHER WFE PUMP 19 192115 O RING 112 0 487x0 103 Buna N 70 QTY 2 20 350013 O RING LID CH WF 2 436 21 357195 HOUSING WFE ...

Страница 60: ...rical Specifications Circuit Protection Two pole 20 AMP device at the Electrical Panel Input 230 VAC 50 60 Hz 3200 Watts 16 Amps Intelliflo Performance Curve 31 8 cm 59 5 cm 27 5 cm 0 00 5 00 10 00 15 00 20 00 25 00 30 00 35 00 5 0 10 0 15 0 20 0 25 0 30 0 35 0 M3 HR METERS 3450 RPM 1500 RPM ...

Страница 61: ...l modes To re enable the IntelliFlo s internal anti freeze protection the power to the drive must be cycled off then back on Blocked system Detects a blocked suction line This alarm resets automatically after 30 seconds and the pump restarts System service soon Alerts the operator that the pump discharge pressure has reached the Clean Filter Pressure as setup in the Filter Menu The filter status w...

Страница 62: ...ir Ensure that the suction lines pump strainer and pump volute are full of water Clean pump strainer pot Replace gasket Reduced capacity and or head For IntelliFlo alert dis play messages refer to Alerts and Warning on page 59 Air pockets or leaks in suction line Clogged impeller Pump strainer clogged Check suction piping and valve glands on any suction gate valves Turn off electrical power to the...

Страница 63: ...ns Check line voltage if less than 90 or more than 110 of rated voltage consult a licensed electri cian Increase ventilation Reduce ambient temperature Tighten any loose wiring connec tions Motor internal terminal overload protector is open Motor runs too hot Turn power to motor off Check for proper voltage Check for proper impeller or impel ler rubbing Mechanical Troubles and Noise The pump motor...

Страница 64: ...la Amps X Volts X Power Factor Continuous Watts Examples 1 HP E WhisperFlo 7 4 amps X 230 Volt X 90 PF 1532 watts 1 HP Max E Pro 8 0 amps X 230 Volt X 87 PF 1600 watts Once watts are computed convert watts to kilowatts kilo is 1000 and multiply this number by kilowatt hour cost 1 watt 01 Kilowatt 100 watts 1 Kilowatt 1000 watts 1 Kilowatt 1 HP E WhisperFlo 1532 watts or 1 532 Kilowatt x 08 122 per...

Страница 65: ...n to chemical testing a good way to check your water clarity is that the main drain cover should be clearly visible from the deck Automatic pool sweeps booster pump style Usually three to four hours of daily operation during summer and two to three hours daily in the winter are sufficient Start the pool sweep one hour or more after the pool pump has started and stop the sweep one hour or more befo...

Страница 66: ...in accordance with the instructions What the warranty covers Pentair Water warrants its products to be free of defects in material and workmanship during the warranty period If a product proves to be defective in material or workmanship during the warranty period then Pentair Water will at its sole option repair or replace the product with a like product Replacement product or parts may include re...

Страница 67: ...65 IntelliFlo VF Installation and User s Guide Notes ...

Страница 68: ...P N 357220 Rev A ...

Страница 69: ...IntelliFlo VF WICHTIGE SICHERHEITSHINWEISE BITTE LESEN UND BEFOLGEN SIE ALLE HINWEISE BEWAHREN SIE DIESE HINWEISE AUF Montage und Bedienungs anleitung Pumpe mit regelbarem Fluss ...

Страница 70: ...Hersteller Pentair Water Pool and Spa Inc 1620 Hawkins Ave Sanford NC 27330 10951 West Los Angeles Ave Moorpark CA 93021 Kundensupport Herentals Belgien 8 00 bis 17 00 Uhr Telefon 32 0 14 25 99 11 Website www pentairpooleurope com Geschützt durch anhängige US Patente Wichtige Sicherheitshinweise 3 Abschnitt 1 Einführung 6 IntelliFlo Übersicht 6 Merkmale der IntelliFlo 7 IntelliFlo Motorbaugruppe 7...

Страница 71: ...nen hohen Unterdruck erzeugen wenn sie verstopft ist Aus diesem Grund kann selbst dann wenn nur eine Saugöffnung kleiner als 46 x 58 cm ist jede Person mit dem Körper angesaugt und dort festgehalten werden Dies kann zu Schäden an inneren Organen und zum Ertrinken führen Werden also kleine Saugöffnungen mit dieser Pumpe verwendet um diese Ansauggefahr und einen möglichen Tod zu vermeiden sind minde...

Страница 72: ...n dass alle Systemkomponenten so ausgelegt sind dass sie zumindest 3 5 bar standhalten Wird das System mit einem zu hohen Druck beaufschlagt kann dies zu einem Komponentenversagen mit katastrophalen Auswirkungen oder zu Sachschaden führen Allgemeine Informationen zur Installation Alle Arbeiten sind von einem Elektrofachmann auszuführen und müssen sämtlichen nationalen einzelstaatlichen und lokalen...

Страница 73: ...weniger Montagezeit erforderlich Senkt Energiekosten um bis zu 90 ein umweltfreundliches Produkt Schützt vor Ansaugverlusten bzw Flussunterbrechungen komfortable Sicherheit Schützt vor thermischer Überlastung geringeres Überhitzungsrisiko Erkennt und verhindert Schäden durch Unter und Überspannung Motorschutz Schützt vor Einfrieren Schutz der internen Komponenten Kann mit einem IntelliTouch oder I...

Страница 74: ...F Steuerbaugruppe und Bedienfeld Die IntelliFlo Steuerung besteht aus einem Bedienfeld und der Systemelektronik die die einphasige 230 V Eingangsspannung in 3 Phasen mit variabler Frequenz zur Steuerung des Motors umwandelt Der Mikroprozessor der Steuerung steuert den Motor durch Änderung der Frequenz des bei ihm ankommenden Eingangsstroms wobei die Spannung geändert wird um die Drehzahl zu regeln...

Страница 75: ...s Fortsetzung Pfeiltasten 9 Pfeiltaste Nach Oben Zur Bewegung in die nächst höhere Ebene im Menübaum oder zur Erhöhung um eine Stelle bei der Bearbeitung einer Einstellung Pfeiltaste Nach Unten Zur Bewegung in die nächst tiefere Ebene im Menübaum oder zur Verminderung um eine Stelle bei der Bearbeitung einer Einstellung Pfeiltaste Nach Links Zur Bewegung des Cursors um eine Stelle nach links bei d...

Страница 76: ...h Ansaugen Max Ansaug Fluss 14 09 0023 m3 h Ansaugen Max Ansaug Fluss 14 09 0023 m3 h Ansaugen Max Ansaug Fluss 14 09 0020 m3 h Ansaugen Max Ansaug Fluss 14 09 20 m3 h Ansaugen Max Ansaug Fluss 14 09 15 MIN Ansaugen Max Ansaug Zeit 14 09 0 MIN Ansaugen Max Ansaug Zeit 14 09 Ansaugen MENÜ 14 09 Einrichten der Ansaugfunktion Abschnitt 3 Betrieb der IntelliFlo VF Dieser Abschnitt beschreibt die Verwe...

Страница 77: ...RPM 12m3 h 12 15 FLUSS einst LÄUFT Handbetriebener Modus Fortsetzung Handbetriebener Fluss Modus Drücken Sie die 4 Start Stop Taste um die Pumpe anzuhalten Verwenden Sie die Pfeiltasten Nach Oben und Nach Unten um zur Menüoption FLUSS einstel zu scrollen Drücken Sie zur Auswahl die Select Taste Zur Änderung der Einstellung drücken Sie die Pfeiltasten 5 Nach Links und Nach Rechts um die zu ändernde...

Страница 78: ...s Poolfi lters den Druck sauberer Filter zeigt die IntelliFlo eine Warnung Service in kürze auf der Anzeige des Bedienfelds an siehe Einstellen des Drucks sauberer Filter auf Seite 26 und Beispiel Druck sauberer Filter auf Seite 30 womit angezeigt wird dass der Filter gereinigt oder rückgespült werden muss Die Rückspülung ist wichtig für die Reinigung und Aufrechterhaltung des Clean Filter Menüs w...

Страница 79: ...ung leuchtet 2 Drücken Sie die Vacuum Taste Drücken Sie die Start Stop Taste In der linken oberen Ecke der Anzeige erscheint VAKUUM und zeigt an dass sich die Pumpe im Vakuum Modus befi ndet SPÜLEND 12 15 1 MIN VERBL FILTERSPÜL LÄUFT Vakuum Modus Fortsetzung 3 Verwenden Sie die Pfeiltasten Nach Oben und Nach Unten um die nachfolgenden Bildschirme anzeigen zu lassen RESTZEIT Die verbleibende Zeit d...

Страница 80: ...e bei der IntelliComm aktiv teilt die IntelliComm der IntelliFlo Pumpe die höchste Zahl mit Die IntelliComm kommuniziert immer mit der Pumpenadresse 1 Hinweis Das Bedienfeld der IntelliFlo bleibt aktiv wenn die IntelliFlo mit der IntelliComm verbunden ist Die folgende Tabelle beschreibt die Verdrahtung für die IntelliComm Klemmen Nr Bezeichnung des Anschlusses Spannung Maximale Stromstärke Phasent...

Страница 81: ... IntelliFlo für das Pool und Schwimmbadsystem In diesem Menü können Sie die Sprache des LCD Bedienfelds einstellen eine Adresse für die IntelliFlo Pumpe bei Anschluss an ein IntelliTouch System eingeben die Poolwassermenge in Kubikmetern m 3 festlegen und einen ca Wert für die Poolwassertemperatur wählen Um zum Pooldaten Menü zu gelangen 1 Gewährleisten Sie dass die grüne LED für die Stromversorgu...

Страница 82: ...nn Pumpen bleiben nicht gefüllt das Rohrsystem des Pools übernimmt diese Aufgabe Das Ansaugen ist eine Funktion die immer dann verwendet wird wenn der Motor gestartet wird wobei ein Fluss als Referenz dient Die Funktion Ansaugfl uss gewährleistet den ordnungsgemäßen Betrieb der Pumpe Die Funktion Systemansaug Zeit gewährleistet den ordnungsgemäßen Betrieb des gesamten Poolsystems Pooldaten Wassert...

Страница 83: ...r Menüoption Druck sauberer Filt zu gelangen Drücken Sie zur Auswahl die Select Taste Zur Änderung der Einstellung siehe nachfolgenden Schritt 4 Dieser Parameter kann von 0 1 bis 3 5 bar eingestellt werden Standardeinstellung 1 0 bar Die typische Einstellung für die meisten Pools und Filter liegt zwischen 0 6 bar und 0 7 bar Ansaugen 12 15 0 MIN Systemansaug Zeit MENÜ 12 15 Filter Filter 12 15 965...

Страница 84: ...t da zwei 2 Zyklen bei der Einstellung der Zyklen pro Tag ausgewählt wurden Filter 12 15 2 Zyklen pro Tag Auf der Grundlage von Poolvolumen Durchfl üsse Tag und der Gesamtanzahl von Stunden für Zyklus 1 2 3 4 muss der Fluss berechnet werden Fluss Poolvolumen x Durchfl üsse pro Tag Zyklus 1 Zyklus 2 Zyklus 3 Zyklus 4 Hinweis Nur aktivierte Zyklen werden bei der Berechnung berücksichtigt BEZEICHNUNG...

Страница 85: ... wird Filter Filter Filter 12 15 10m3 h LÄUFT Zeitplan FLUSS WARNUNG Service in kürze 0 7 bar 1 3 bar Filter Menü Fortsetzung Verwendung des Filter Modus in Verbindung mit dem Merkmale Modus Die IntelliFlo startet und stoppt zu den Zeiten die Sie für die Filterzyklen 1 4 eingegeben haben wobei jedoch die Parameter die Sie für die Funktionen im Merkmal Modus nur Merkmal 3 9 eingegeben haben Vorrang...

Страница 86: ...r läuft 2 Drücken Sie die Menu Taste Auf der Anzeige erscheint Pooldaten 3 Verwenden Sie die Pfeiltasten Nach Oben und Nach Unten um zur Menüoption Zeit Kontr zu gelangen Drücken Sie zur Auswahl die Select Taste Die Anzeige Zeit erscheint a Zum Einstellen der Systemuhr Drücken Sie die Select Taste um die Menüoption Zeit auszuwählen b Zum Einstellen des Kontrasts der LCD Hintergrundbeleuchtung der ...

Страница 87: ... in der M O Flo Einstellung eingeben und hält die Zielgeschwindigkeit für die Zeitdauer aufrecht die Sie für den Parameter Laufzeit einstel eingeben M O Flo läuft nur während der Filterzyklen die Sie für den Filter Modus eingeben Beispiel Sie haben ein Poolheizsystem installiert das eine Flussgeschwindigkeit von mindestens 12 m 3 h benötigt um das System durch Betätigen eines internen Druckschalte...

Страница 88: ...2 Dauer 1 Minute 10 Stunden bzw 00 01 10 00 Standardeinstellung 00 01 Legt die Zeitdauer für den Betrieb von Merkmal 1 oder 2 fest Die Zeitdauer muss für Merkmal 1 und 2 ausgewählt werden F3 Startzeit einstellen 00 00 23 59 Standardeinstellung 06 00 am Legt die Startzeit für Merkmal 3 fest F3 Stoppzeit 00 00 23 59 Standardeinstellung 06 10 Legt die Stoppzeit für Merkmal 3 fest F4 Startzeit 00 00 2...

Страница 89: ... Fortsetzung Einrichten von Merkmal 3 9 Um zum Menü Merkmale 3 9 zu gelangen 1 Gewährleisten Sie dass die grüne LED für die Stromversorgung leuchtet und die Pumpe nicht mehr läuft 2 Drücken Sie die Menu Taste Auf der Anzeige erscheint Pooldaten 3 Verwenden Sie die Pfeiltasten Nach Oben und Nach Unten um zur Menüoption Merkmale zu scrollen Drücken Sie zur Auswahl die Select Taste Auf der Anzeige er...

Страница 90: ... m 3 h 8 00 22 00 Ursprünglicher Filterzyklus ohne Zeitfunktion Filterzyklus Merkmal 3 8 00 10 m 3 h 20 m 3 h 21 00 19 00 18 00 Neuer Fluss Zeitoptimierter Filterzyklus Merkmale Menü Fortsetzung Einrichten von M O Flo Um zum M O Flo Menü zu gelangen 1 Gewährleisten Sie dass die grüne LED für die Stromversorgung leuchtet und die Pumpe nicht mehr läuft 2 Drücken Sie die Menu Taste Auf der Anzeige er...

Страница 91: ...rollen Drücken Sie zur Auswahl die Select Taste Standard einstellung 3400 U min Zur Änderung der Einstellung siehe nachfolgenden Schritt 4 e Um die Zeitdauer für die Welle bzw Impuls Funktion einzustellen V erwenden Sie die Pfeiltasten Nach Oben und Nach Unten um zur Einstellung Dauer zu scrollen Drücken Sie zur Auswahl die Select Taste Standardeinstellung 10 Sekunden oder 0010 Zur Änderung der Ei...

Страница 92: ...iv Aktivierg Externe Kontrolle Menü Fortsetzung 4 Zur Änderung einer Einstellung drücken Sie die Pfeiltasten Nach Links und Nach Rechts um die zu ändernde Stelle auszuwählen und verwenden dann die Pfeiltasten Nach Oben und Nach Unten um die ausgewählte Stelle zu ändern 5 Sobald Sie fertig sind drücken Sie die Enter Taste um die Änderungen zu speichern Um die Eingabe von Änderungen abzubrechen drüc...

Страница 93: ...Schmutz darin befi nden schauen Sie von oben durch das Schauglas in den Korb Unabhängig vom zeitlichen Abstand zwischen den Filterreinigungen ist es äußerst wichtig die Fremdkörperfalle mindestens einmal pro Woche einer Sichtkontrolle zu unterziehen Ein verschmutzter Korb führt zur Verminderung der Filterleistung und möglicherweise der Heizvorrichtung WARNUNG ÖFFNEN SIE NICHT den Siebkorb wenn die...

Страница 94: ... zur Einlagerung im Winter usw abgedeckt jedoch nicht mit Plastikmaterialien umwickelt werden was aber unter keinen Umständen während des Betriebs oder für einen anstehenden Betrieb gilt Wenn Sie den Motor ersetzen stellen Sie sicher dass die Motorhalterung richtig positioniert ist um die installierte Größe des Motors zu tragen Clamp Lid Volute Überwinterung Der interne Frostschutz der IntelliFlo ...

Страница 95: ...d 1 gerade Saug und Rücklaufl eitungen um Reibungsverluste zu vermeiden und die Leistung zu erhöhen Installieren Sie die Pumpe mindestens 1 5 m bzw fünf 5 Fuß entfernt von der Innenwand des Pools bzw 2 Schwimmbads Bei kanadischen Anlagen ist ein Minimum von drei 3 Metern vom Poolwasser gefordert Installieren Sie die Pumpe mindestens 60 cm bzw zwei 2 Fuß vom Einlass der Heizvorrichtung entfernt 3 I...

Страница 96: ...leisten Sie dass vor dem Verkabeln alle Hauptschalter und sonstigen Schalter ausgeschaltet sind 2 Gewährleisten Sie eine Anschlussspannung von 230 V AC 3 Verwenden Sie AWG 12 für Leitungen bis 30 m bzw 100 Fuß und AWG 10 für Längen über 30 m bzw 100 Fuß Im Zweifelsfall verwenden Sie ein dickeres Kabel größerer Durchmesser Mit einem dickeren Kabel kann der Motor kühler und effi zienter laufen Die I...

Страница 97: ...er 9 Welle drehen Sie das Laufrad entgegen dem Uhrzeigersinn Entfernen Sie den rotierenden Teil der 10 mechanischen Dichtung vom Laufrad Entfernen Sie die vier Schrauben von 11 der Dichtungsplatte am Motor mit einem 9 16 Schraubenschlüssel Legen Sie die Dichtungsplatte mit der 12 Oberseite nach unten auf einer ebenen Oberfl äche ab und klopfen Sie den Sitz der Kohlefeder heraus Reinigen Sie die Di...

Страница 98: ... die Motorbaugruppe auf 4 Sichern und befestigen Sie die Steuerungsbaugruppe mit den drei Kreuzschlitzschrauben Kreuzschlitzschrauben Kreuzschlitzschrauben Diese Schrauben nicht entfernen Adapterstecker Dichtung Orange Motorstiftkappen Stck 3 22 25 15 26 23 3 27 24 4 2 28 17 29 11 18 16 13 10 6 12 14 8 5 9 7 19 21 1 20 30 31 33 Ersatzteile Artikel Nr Teile Nr Bezeichnung 1 070387 KORB AQ WF 2 0704...

Страница 99: ...rhöhte Temperaturzustand behoben ist Frostschutz Wenn aktiviert läuft der Motor 60 min bei 1000 U min Nur im Filter und handbetriebenen Modus aktiviert Um den internen Frostschutz der IntelliFlo erneut zu aktivieren muss die Stromversorgung der Steuerung aus und dann wieder eingeschaltet werden System blockiert Eine verstopfte Saugleitung wurde festgestellt Dieser Alarm setzt sich automatisch nach...

Страница 100: ...tor und die Dichtungsplatte am Gehäuse Setzen Sie die 6 Schrauben um die Dichtungsplatte und das Gehäuse wieder ein und ziehen Sie sie fest Reinigen Sie den Ansaugabscheider Fehlerbeseitigung Fortsetzung Problem Mögliche Ursache Beseitigung Unzureichende Zirkulation Siehe Mitteilungen auf der Alarmanzeige der IntelliFlo unter Alarme und Warnungen auf Seite 59 Überlast Pumpe Kontrollieren Sie den A...

Страница 101: ...hnungen Der Schlüssel zum Energiesparen bei Ihrem Pool ist die richtige Einstellung der Filterpumpenzeit Pooltemperatur und Beleuchtung Beachten Sie folgende Hinweise wenn Sie Ihren Swimming Pool betreiben Verwendung der IntelliFlo Pumpe Ihr Pool muss alle 24 Stunden gefi ltert werden Die Zeit zum Filtern des Pools ist abhängig von der Größe Ihres Pools der Filterausrüstung wieviel Sie Ihren Pool ...

Страница 102: ...Die Gewährleistung umfasst Folgendes Pentair Water gewährleistet dass seine Produkte während der Gewährleistungsfrist frei von Material und Verarbeitungsfeh lern sind Wird während der Gewährleistungsfrist festgestellt dass ein Produkt Material oder Verarbeitungsfehler aufweist kann Pentair Water nach alleinigem Ermessen das Produkt reparieren oder durch ein gleichwertiges Produkt ersetzen Zur Ersa...

Страница 103: ...P N 357220 Rev A ...

Отзывы: