35
IntelliChlor Electronic Chlorine Generator Installation and User’s Guide
System Specifications - 110 VAC and 230 VAC Wiring
Circuit Protection:
Two-pole 20 AMP device at the electrical panel.
IntelliChlor Model IC20, IC40 and IC60
Input: 95-130 VAC, 50/60 Hz, 220 Watts (2 AMP) or 220-240 VAC, 50/60 Hz, 220 Watts (1 AMP).
Output: 22-39 VDC @ 7.5 AMPS maximum from the Power Center.
Water flow: 25 gallons per minute minimum. 105 gallons per minute maximum. Maximum pressure: 75 psi
115 VAC Basic System Wiring with Pool Pump Timer
IMPORTANT: When using IntelliChlor with an IntelliTouch system, it is recommended to wire
the Power Center to the pump side of the relay located in the IntelliTouch Load Center. This
method does not require a ground fault circuit-interrupter (GFCI) to protect the circuit.
IntelliChlor (SCG) AC Wiring Instructions:
When using the IntelliChlor salt
chlorine generator and an IntelliFlo pump (or 2-speed pump) with a Pentair
Water Pool and Spa
®
IntelliTouch®, EasyTouch® or SunTouch® automation
control system , the IntelliChlor AC power center wires must be connected to
the PUMP SIDE OF THE MAIN FILTER PUMP RELAY located in the load/power
center (see page 31 for diagram). This ensures that the IntelliChlor cell
produces chlorine only when the main filter pump is on. This method does not
require a ground fault circuit-interrupter (GFCI) to protect the circuit. Note: For
non-automation systems using a time clock, see disgram below.
Содержание IntelliChlor IC60
Страница 12: ...6 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Страница 22: ...16 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Страница 26: ...20 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Страница 30: ...24 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Страница 38: ...32 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...