horNET Giga PCI (P6111-1) 

 

9

Cabling 

To ensure that the device can transfer data at the desired speeds, networking cables must 
meet appropriate standards. 

1000 Mbps:

 Data transfer at 1000 Mbps requires Cat. 5 cables (Cat. 5e recommended) with 

all four wire pairs terminated in an RJ-45 connector. For a straight-through cable, both 
connectors must be terminated according to the EIA/TIA 568B wiring standard. For a 
crossover cable, one connector must follow EIA/TIA 568A and the other must follow EIA/TIA 
568B. 

100 Mbps:

 Data transfer at 100 Mbps requires a Cat. 5 cable with correctly terminated 

connectors (see 1000 Mbps); this standard only uses two wire pairs.  

10 Mbps:

 Data transfer at 10 Mbps requires Cat. 3, 4 or 5 cables with correctly terminated 

connectors (see 1000 Mbps). This standard also only uses two wire pairs. 
 

Status LEDs 

Two LEDs are located on the card’s bracket (the metal part visible on the outside of the 
computer), which indicate the card’s connection speed and port activity. 
 

Designation

 

Color

 

Function

 

1000 ACT 

Green 

On: 1000 Mbps connection 
Flashing: Data transfer 

10/100 ACT 

Orange 

On: 100 Mbps connection 
Flashing: Data transfer 

 

PING 

A method commonly used to verify correct network operation is to use the PING command, 
which can be run from the command line interface. In order to open the command line dialog 
under Windows 95, 98 or Me, open the 

Start

 menu, select 

Run

 and then type 

COMMMAND.COM

 

and click 

OK

. Under Windows 2000 and XP, use the same procedure to launch the command 

line interface, replacing 

COMMMAND.COM

 with 

CMD.EXE

. PING syntax is explained below. 

 

PING [options] target_name 

 
The following options are available: 

-t

 

Ping the specified host until stopped. 
To see statistics and continue - type Control-Break; To stop - 
type Control-C. 

-a

 

Resolve addresses to hostnames. 

-n count

 

Number of echo requests to send. 

-l size

 

Send buffer size. 

-f

 

Set Don’t Fragment flag in packet. 

-i TTL

 

Time To Live. 

-v TOS

 

Type Of Service. 

-r count

 

Record route for count hops. 

-s count

 

Timestamp for count hops. 

-j host-list

 

Loose source route along host-list. 

-k host-list

 

Strict source route along host-list. 

-w timeout

 

Timeout in milliseconds to wait for each reply. 

 

Содержание horNET Giga PCI

Страница 1: ...Installation and Operation Manual PENTAGRAM horNET Giga PCI P6111 1 The latest versions of manual drivers and applications are available on www pentagram eu 2008 04 16 ...

Страница 2: ...ation and technical specifications provided in this manual are subject to change without notice and or indication Copyright 2007 PENTAGRAM All rights reserved Unauthorized duplication and copying prohibited 2008 04 16 ...

Страница 3: ...N 5 PACKAGE CONTENTS 5 SYSTEM REQUIREMENTS 5 FEATURES 6 TECHNICAL SPECIFICATIONS 6 INSTALLATION 7 INSTALLING THE CARD IN YOUR COMPUTER 7 DRIVER INSTALLATION 8 VALIDATING THE INSTALLATION 8 CABLING 9 STATUS LEDS 9 PING 9 GLOSSARY OF KEY TERMS 11 ...

Страница 4: ...horNET Giga PCI P6111 1 4 ...

Страница 5: ...roductively and to play the latest multiplayer games with your friends The PENTAGRAM horNET Giga PCI P6111 1 network interface card is based on the state of the art Realtek RTL8169SC chip which is a Fast Ethernet controller contained in a single highly integrated circuit The chip supports the ACPI Advanced Configuration Power Interface functionality for PCI cards to ensure efficient power manageme...

Страница 6: ...t for high performance at low CPU load PCI 2 1 and PCI 2 2 compliance Automatic IRQ interrupt request and I O input output address configuration Technical specifications Data rate 10 Mbps 100 Mbps 1000 Mbps autonegotiation Transfer mode 10 100 Mbps half duplex full duplex autonegotiation 1000 Mbps duplex Standards supported IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE 802 3ab 1000Base T IEEE 80...

Страница 7: ...ly or disconnect the power cord from the computer 2 Open the computer s case 3 Select a vacant PCI slot Port appearance Port name PCI Express x16 AGP AGP Pro PCI 4 Insert the card gently into the selected PCI slot and then attach it to the chassis using a screw Retaining screw Network card PCI slots Mainboard 5 Attach the appropriate network cable to the connector on the network interface card 6 C...

Страница 8: ...e driver 1 Insert the driver CD into the CD ROM drive 2 The setup wizard will be launched automatically If the CD ROM Autorun feature is disabled run Setup exe in the CD s root directory 3 Click Driver 4 The driver will be installed and the Driver Install Completed message will be displayed Validating the installation In order to validate the device installation click on the Start menu and select ...

Страница 9: ... activity Designation Color Function 1000 ACT Green On 1000 Mbps connection Flashing Data transfer 10 100 ACT Orange On 100 Mbps connection Flashing Data transfer PING A method commonly used to verify correct network operation is to use the PING command which can be run from the command line interface In order to open the command line dialog under Windows 95 98 or Me open the Start menu select Run...

Страница 10: ... 168 2 2 bytes 32 time 1 ms TTL 128 Ping statistics for 192 168 2 2 Packets Sent 4 Received 4 Lost 0 0 loss Approximate round trip times in milliseconds Minimum 0ms Maximum 0ms Average 0ms The above messages show examples of results obtained by running PING Your results may vary although the differences should not be significant Packet round trips should be as short as possible however if the cabl...

Страница 11: ... m 1 640 ft 10Base T Data rate 10 Mbps twisted pair cable maximum segment length 100 m 328 ft 10Broad 36 Data rate 10 Mbps coaxial cable maximum segment length 3 600 m 11 800 ft 10Base F Data rate 10 Mbps fiber optic cable maximum segment length 4 km 2 5 mi 100BaseTX Data rate 100 Mbps maximum segment length 100 m 328 ft 1000Base T Data rate 1000 Mbps maximum segment length 100 m 328 ft 100VG AnyL...

Страница 12: ...ned for programmers who develop IBM LAN Server Microsoft LAN Manager and OS 2 local area networking software It establishes communications sessions between computers and manages the connections IPX IPX is a peer to peer networking protocol built into Novell NetWare Organizational units Workgroups Workgroups provide a simple method for organizing computers and users on a local area network into log...

Страница 13: ...egment means a section of a cable which serves as a bus Signals broadcast within a segment reach every workstation connected to that segment Host A host is a device e g a computer or a printer to which a network address is assigned WINS WINS Windows Internet Name Service supports distinguishing between computer names by translating them to assigned IP addresses and performs a reverse process i e r...

Страница 14: ...horNET Giga PCI P6111 1 14 NOTES ...

Страница 15: ...horNET Giga PCI P6111 1 15 NOTES ...

Страница 16: ...horNET Giga PCI P6111 1 16 NOTES ...

Отзывы: