14
14
Anchoring the Tub – “Peninsula Installation” (1 Wall – Side)
This anchoring procedure describes the steps for anchoring the tub in a single wall type
installation as shown in figure 1 under “Peninsula Installation - 1 Wall - Side”.
1.
Follow the steps for anchoring the tub under “Anchoring the tub – “Alcove Installation” (2 or 3
Walls)”
2.
Install an additional anchor into the floor just inside the access door on the side opposite from
the wall.
Electrical Connections
This unit is to be connected only by a licensed electrician. A minimum of 15 amp 120 volt
service is required with ground fault circuit interrupter.
Warning: Ensure that the power supply is turned off before
attempting to connect to the tub. Failure to do this could result in injury or
death to the installer.
1.
Remove the cover from the small field wiring junction box mounted to the tub frame. It is
located inside the access door on the right side of the tub and below the larger electrical box.
2.
Connect the electrical supply conduit to the small field wiring junction box top.
3.
Connect the line wire (normally black) to the black wire of the tub. Connect the neutral wire
(normally white) to the white wire of the tub. Connect the ground wire (normally green or
yellow & green) to the green and yellow wire of the tub. These connections can be made with
wire nuts.
4.
Push the wires back into the box and replace the lid.
5.
Turn ON the power to the tub.
6.
Turn ON the tub’s circuit breaker located on the top of the larger electrical box. That box is
mounted to a sliding “drawer” that can be pulled out through the access door opening.
7.
If the blower motor starts running, find the “Aqua-Aire ON/OFF” button on the control panel
of the tub and press it once to turn off the blower.
8.
Switch the tub’s circuit breaker, located on the top of the electrical box, to the OFF position.
Water Supply and Drain Connections:
Note: It is highly required that a licensed plumber make the final connections of the hot
and cold water supply and the connection to the drain.
1.
Connect the supply hoses (hot and cold water supply) to the respective ports on the tub.
Ensure that there are sealing gaskets within the swivel fittings on the hoses.
2.
Connect the drain (waste) of the tub to the facility’s drain system.
3.
Close the water door of the tub, place the drain plug into the drain, and open the facility’s
supply valves to the tub and check for leaks.
Содержание Cascade Alcove
Страница 4: ...4 4 Figure 3 Basic Dimensions Cascade Alcove...
Страница 8: ...8 8 Figure 8 Drain pipe from the wall...