![Penman Collection VEGA C7 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/penman-collection/vega-c7/vega-c7_installation-instructions-manual_1523904004.webp)
1.0 USER INSTRUCTIONS - REMOTE CONTROL
1.6 Igniting the flame (remote control)
Open the gas shut-off cock that has been installed in the gas pipe to the unit.
Press the “
O I
” switch on the gas control block to the “
I
” position.
Turn the operating button on the gas control block into the
ON
position.
Press the
OFF
and (large) switches on the remote control at the same time. A short sound signal
will confirm commencement. Short sound signals will then follow until the pilot light and main burner are
ignited. Once the main burner is ignited, the flame will adjust to its maximum height automatically.
1.7 Possible error messages
Long sound signals during ignition: Receiver batteries are almost empty. After this signal is heard, the unit
may be switched on approximately 10x more times.
5 seconds of continuous sound signal: Error message. For example, one of the cables is not connected, the
“
O I
” switch is not in the “
I
” position.
5x short sound signal: The pilot light or main burner are not ignited. Possible cause: air in the pilot pipes.
1.8 Setting the flame height / extinguishing the flame
After the burner is ignited, the flame size will adjust to its maximum height automatically.
Press the button (small) on the image of the flame to reduce the height and to switch the burner off.
(Extinguishing the flame: “
STAND BY
”). (Press the key for a short time to gradually reduce the flame.)
Press the (large) button to increase the flame height. (Press the button briefly to gradually increase
the flame height).
1.9 Switching the unit off.
Press the (small) button to reduce the flame height and to switch the burner off (“
STAND BY
”).
Then press OFF to switch off the entire unit, including the pilot light.
If the unit is out of use for a long period, set the “
O I
” switch on the gas control block to the “
O
” position
to save the batteries.
In this case, it is also recommended you close the gas shut-off cock in the supply line.
Breakdowns:
If the receiver is not receiving signals from the manual transmitter effectively, this could be caused by:
1. Flat batteries: replace the batteries.
2. An electronic problem: press “
RESET
” on the receiver.
Contact your fitter if the unit switches off regularly.
PAGE 4
Piëzo Ignitter
(Manual)
Manual knob
Main valve knob
Microswitch
“
O I
” Switch
8 Wire Receiver Jack
Combination Control Cover
IMPORTANT: If the pilot light is extinguished, wait at least 5 minutes before repeating the steps
above.