6.0 INSTRUCTIONS FOR MERTIK MAXITROL GV60 GAS CONTROL 

 
Ensure that the fuel supplied to the unit is clean and free from particles and moisture. 

Before a gas supply pipe (new or existing) is connected to the main gas pipe at the gas meter and to the gas 

control block of the unit, clean and dry compressed air should been blown through it.  Cut copper pipes as well as 

aluminium pilot pipes must be deburred and blown clean before they are connected.  The dust filter at the  

connection to the gas control block will only filter out the coarsest dirt from the system.  Fine particles are still 

able to reach the inside and may damage and/or adversely affect regulation in the gas control block. 

 

Heat, moisture and dust are a threat to all electronic components. 

Protect the electronic gas control 

until 

all construction, plastering and paintwork has been completed.  If such 

work cannot be avoided, then protect the control against dirt and moisture penetration by using, for example 

plastic film. 

 

Only place the batteries 

after

 wiring to the receiver, gas control block and pilot set is connected. 

Premature connection to the energy source may damage the control’s CPU (central processor). 

 

Ensure that the ignition cable is not near the antenna wire and that they do not cross each other. 

The high voltage released at ignition may damage the sensitive receiver circuit.  This may mean that the unit 

becomes less responsive or not responsive at all to handset commands. 

 

Prevent leakage of the ignition spark to other parts of the installation than the Ignition by the pilot. 

Keep the ignition free of hull or other metal parts. If cable extension is used, see to it that connections are  

additionally insulated with a silicone grommet. 

 

For automatic start via the transmitter, the receiver and the control the gas control valve should be  
switched. 

The oval disk on the gas control block should be turned to the ON position. The 

I/0 

switch should to be set to 

"

I

". The ignition must be connected to the receiver box at the terminal 

SPARK

 

The transmitter's contains the thermostat sensor system. 

The transmitter operates best at 2 to 3m from the unit. Although the communication via short wave radio  

signals takes place, it is recommended that the transmitter in the 'visibility' of to lay the gas apparatus in  
a place where the user wants to experience a pleasant temperature. Place the hand transmitter in direct  

sunlight or other hot places. The thermostat measures the temperature and regulates the flame size of the  

gas in accordance. 

 

Remove batteries only with the red ribbon which is under the battery, not with a metal tool. 

Removing batteries with a metal object can permanently damage the electronic control. 

IMPORTANT: 

Electronic components will become permanently faulty when exposed to temperatures higher 

Than 60°C.  Standard AA batteries will crack open at temperatures >54°C and the battery contents will  

damage the electronic switches located underneath.  Batteries last longest at <25°C.  At >50°C the life span is 

around 23 weeks, this makes the use of the gas fire unnecessarily expensive. 

Only install the gas control block and receiver as pre-installed at the factory.

 

 

Remember that components may have to be replaced or that repairs may have to be performed at a later date. 

This may be more difficult if the control is installed using a method that is different from the instructions  

provided here. 

NOTE: Do not tighten the contact breaker and the thermocouple connection too tightly on the gas 

control block or to each other.  

It is sufficient to tighten by hand and add a half a turn with an open-end 

spanner.  Tightening too much will break the connection to the magnetic coil below and/or the insulation 

around the aluminium contact pin in the contact breaker. This may lead to the magnetic coil not opening the 

gas supply to the pilot and the unit not working. 

PAGE 10 

IMPORTANT: 

Do not start up the unit if the window is not present or broken. 

Содержание VEGA C7

Страница 1: ...INSTALLATION INSTRUCTIONS VEGA C7 CONVENTIONAL FLUE GAS STOVE VC7 REV A 08 17...

Страница 2: ...ire 2 3 Switching the unit off 3 0 INSTALLATION INSTRUCTIONS Page 7 3 1 General instructions 3 2 Chimney preparation 4 0 POSITIONING THE APPLIANCE Page 8 4 1 Installation of the flue liner 4 2 Connect...

Страница 3: ...rted press the OFF button and small at the same time to toggle between F and 12 hour clock and C and 24 hour clock Wait a moment or press OFF to return to MAN mode 1 4 Setting the time Press large and...

Страница 4: ...rner is ignited the flame size will adjust to its maximum height automatically Press the button small on the image of the flame to reduce the height and to switch the burner off Extinguishing the flam...

Страница 5: ...nect the new battery and place the whole unit back Close the cover 2 Receiver Carefully remove the entire receiver from the holder Slide the small cover open Remove the batteries from the battery hold...

Страница 6: ...e pilot flame is burning through the glass window If the pilot flame is alight keep the metal circle pressed down for another 10 seconds and then let go Turn the manual knob to the ON position The bur...

Страница 7: ...umulate Under no circumstances should the Oxypilot be altered or bypassed in anyway If after a period of use the appliance shuts down for no apparent reason the consumer should be informed to stop usi...

Страница 8: ...xt open the door of the gas appliance and take all the packaged components out check to make sure they are not damaged or broken Fit the ceramic log set see section appendix 3 page 22 Replace the cast...

Страница 9: ...o ignition Gas connection 3 8 External Unit category B11BS Pilot flame SIT 3 flames PAGE 9 Main valve knob Thermocouple c Pressure regulator Ignition connection Pilot gas adjustment MAN knob Side inle...

Страница 10: ...k should be turned to the ON position The I 0 switch should to be set to I The ignition must be connected to the receiver box at the terminal SPARK The transmitter s contains the thermostat sensor sys...

Страница 11: ...I2H I3B P PL I3B P SI I2H I3B P SK I2H TR I2H I3B P CATEGORY I2L I2ELL I2H I3P I3 I3B P I2E I2E GAS TYPE G25 G25 G20 25 G31 G30 31 G20 25 G20 25 PREPRESSURE MBAR 25 20 20 30 37 50 28 30 37 50 20 20 BU...

Страница 12: ...s and label on receiver OK Transmitter receiver range limited 1 Move antenna cable see instructions 2 Replace receiver Optional wall switch cabling not operating properly Replace wall switch cabling R...

Страница 13: ...on see instructions Add ground wire between pilot burner and gas valve Do not coil the IGN cable Shorten IGN cable if possible NO IGN sequence stops no pilot flame Transmitter command is possible IGN...

Страница 14: ...smitter command receiver does not react Press RESET button see instructions Add ground wire between pilot burner and gas valve OK Do not coil the IGN cable Shorten IGN cable if possible 7 Main burner...

Страница 15: ...r point or jumps c Check whether the electrode is broken The pilot flame will not remain alight after ignition 1 Check whether the pilot flame is large enough to burn around the thermocouple If the fl...

Страница 16: ...materials A combustible shelf may be fitted over the appliance up to a depth of 150mm there must be a minimum 280mm clearance above the top of the stove An increase in shelf depth requires an equal in...

Страница 17: ...ENDIX 2 PREPARATION AND INSTALLATION PAGE 17 1 2 3 NOTE Some models may feature hexagonal nuts instead of wingnuts In this scenario a suitable socket wrench or spanner can be used to tighten loosen th...

Страница 18: ...o account 1 No glowing material should be placed on or near the pilot burner 2 Ensure that no ceramic material can fall on to the glass seals as this can damage the glass 3 The slot opening between th...

Страница 19: ...APPENDIX 3 CERAMIC LOG SET PLACEMENT PAGE 19 7 8 9 10 11 12...

Страница 20: ...Brought to you by Imperial Point Express Trading Estate Stone Hill Road Farnworth Bolton BL4 9TN Tel 01204 868 550 Fax 01204 868 551 Email sales percydoughty com www visionfires co uk...

Отзывы: