2.0 INSTALLATION
2.1 Installation guide
In the absence of pertinent installation information, the British standards and current building regulations must be followed
to ensure compliance and safety.
This appliance must be installed by a HETAS registered engineer and the installation must be in accordance with the British
standards and current building regulations. Please see below for guidance but not limited to and the statutory requirements.
BS 8303
BS EN 15287 1
BS EN 15316
BS EN 1856 – 1 2009
BS EN 1856 – 2 2009
Approved Doc J
Health and Safety at Work Act
The Provision and Use of Work Equipment regulations
Personal Protective Equipment at Work regulations
Construction Design and Management regulations
Control of Asbestos
Working at Height regulations
Manual Handling regulations
The stove may be installed in to a location where additional fire protection measures need to be taken into consideration. A
risk assessment must be completed by the registered HETAS installation engineer or the principal designer for purposes of the
current Construction Design & Management Regulations.
Please see the technical data below for clearances to combustible materials, this will allow for a comprehensive risk
assessment to be completed.
PAGE 7
Material
Cast iron/steel
Ventilation requirements Surface
In accordance with
British Standards
Surface door rope size
12mm
Output
5kW
Overall dimensions mm (HxWxD)
957 x 520 x 413
Weight
98kg
Draught pressure max
20pa
Draught pressure min
12pa
Tertiary air
Yes
Combustion System
Primary/secondary
Heating area
90m3
Flue outlet options
Top and rear
Flue collar size
125mm
Average temp at flue collar
348
°c
Distance from bottom of stove to
centre of rear flue outlet
839mm
Diameter of external flue spigot
100mm
Distance from bottom of stove to
centre of direct air connection
190mm
Log size
250mm
Fuel weight
1.3kg
Moisture content
16%-20%
Distance to combustibles (side)
300mm
Distance to combustibles (rear)
200mm
Distance to combustibles (front)
500mm
Safety distance to combustibles
materials (furniture)
100mm
Adequate distance left for mainte-
nance (rear and sides)
150mm