34
Cyclone MAX User Manual
CYCLONE MAX
your S19 file contains the correct data, “Ignore S19 Range” may be checked.
This will cause any out of range errors to be ignored.
Erase If Not Blank
This command performs a blank check of the module and erases it if it is not
blank.
Erase Module
If “Erase Module” is specified, the Cyclone MAX will perform an “Erase
Module” on the target device after entering the Monitor Mode or BDM mode.
Blank Check Module
If “Blank Check Module” is checked, the Cyclone MAX will perform a “Blank
Check Module” on the target device.
Program Bytes
Prompts for a starting address, which must be in the module. You are then
asked to enter a hexadecimal byte to be programmed into the current
location. Clicking the OK button will automatically advance to the next data
byte location.
Program Module
For this command to work, you must have previously selected an S-record
file.
Verify Module
For this command to work, you must have previously selected an S-record
file.
Verify Checksum
This command verifies the module content via a CRC calculation.
4.1.7
Store Image To Cyclone
“Store Image to Cyclone” allows the current configuration to be programmed
Содержание Cyclone MAX