background image

#500615-001 - 

Product Manual: Model #TFAT-11A TELESCOPIC FALL ARREST TOWER

 - Revision 01 - Date: 04-29-2010

Page 11

SAFETY ALERT SYMBOL

This Safety Alert symbol means 

ATTENTION! BECOME 

ALERT! YOUR SAFETY IS INVOLVED!

The Safety Alert symbol identifi es important safety messages 
on your Pelsue Retrieval Product and in the manual. When 
you see this symbol, be alert to the possibility of personal 
injury or death. Follow the instruction in the safety mes-
sage.

Why is this symbol important to you?

3 BIG Reasons: 

Accidents Disable and Kill.

 

Accidents Cost You Money.

 

Accidents Can Be Avoided.

4.2 - Safety Alert Symbol

4.3 - General Safety Information

1.  Read, understand, and follow the Product Manual and all safety signs before using, maintaining or inspecting the 

equipment.

2.  Refer to and follow applicable standards and regulations. Comply with requirements of local regulations for your 

applications.

3.  Establish an equipment-use training program for inexperienced employees. Only trained, competent persons shall 

use the equipment. An untrained operator is not qualifi ed to operate the system.

4. Have 

fi rst-aid kit available for use should the need arise and know how to use it.

5. Provide 

fi re extinguisher for use in case of an accident. Store in a highly visible place.

6.  Install and properly secure all guards and shields before operating.

7.  Wear appropriate protective gear. This list includes but is not limited to:

 

•  A hard hat

 

•  Protective shoes with slip resistant soles

 • 

Heavy 

gloves

 • 

Protective 

clothing

 • 

Face 

Protection

8.  Review and follow the Pre-Operation Checklist before using a component in the system or system itself.

9.  Establish a regular maintenance and inspection program with your equipment and maintain detailed records.

10. Review safety related items and operating instructions with all personnel on a regular basis.

4.4 - Operating Safety

1.

 

Read, understand and follow the Product Manual as well as all printed warnings that may be located on the product itself 
before using, maintaining or inspecting the equipment.

2.

 

Train all operators before allowing them to use the product. An untrained operator exposes themselves, bystanders 
and workers to possible serious injury or death.

3.

 

Visually inspect the product and all auxiliary components and equipment before using. Correct any problems before 
using the equipment.

4. 

Securely anchor the product before using.

5.

 

Use only certifi ed anchor and connector components in your system.

6.

 

Use only an approved full body harness for the workers.

Содержание TFAT-11A

Страница 1: ... Model TFAT 11A Telescopic Fall Arrest Tower T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Tel 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ISO 9001 Certified ...

Страница 2: ... 500615 001 Product Manual Model TFAT 11A TELESCOPIC FALL ARREST TOWER Revision 01 Date 04 29 2010 Page 2 ...

Страница 3: ...ed a continuing reputation for excellence in the production of fine products for a broad spectrum of industry throughout the world Now in our second generation of family direction continued commitment to innovation and quality makes Pelsue a leading source of equipment for many types of confined spaces We specialize in safety retrieval fall arrest ventilation cable placing splicing and maintenance...

Страница 4: ...on 7 2 1 Serial Number 3 0 Configuration Assembly 8 3 1 Label Locations 4 0 Safety 10 4 1 Warning Statement 4 2 Safety Alert Symbol 4 3 General Safety Information 4 4 Operating Safety 4 5 Maintenance Safety 4 6 New Operator Safety Information 5 0 Product Operation 13 5 1 Product Description Capabilities 5 2 Product Installation Set Up 6 0 Maintenance Inspection 18 6 1 Maintenance 6 2 Inspection 6 ...

Страница 5: ...TOMER SATISFACTION IS ONE OF THE DIFFERENTIATORS THAT SETS YOU APART FROM THE PACK AND YIELDS A COMPETITIVE ADVANTAGE THEREFORE WE WILL SUPPORT TOTAL CUSTOMER SATISFACTION BY IMPLEMENTING THE ISO 9001 QUALITY SYSTEM AND PROVIDING THE NECESSARY ATMOSPHERE AND TRAINING TO NURTURE THIS CONCEPT THROUGHOUT OUR ORGANIZATION WE WILL MAKE EVERY BUSINESS DECISIONAS THOUGH THE QUALITY OF THE PART OR SERVICE...

Страница 6: ...be covered by this warranty Unless otherwise agreed the T A Pelsue Company shall repair or replace the defective components within 30 calendar days of notice of failure T A Pelsue Company s obligation hereunder shall be limited to the repair or replacement of the product or component as set forth above and shall not include any liability whatsoever for damages caused by such failure including but ...

Страница 7: ...nd specific information Keep this manual available for future reference and for usage as a tool in the instruction of new operators Establish a regular training program for all operators Establish a regular maintenance and inspection program to keep the equip ment in top condition This product is a part of a complete Fall Arrest System The user must read understand and follow the instructions cont...

Страница 8: ...separated for shipping purposes If this is the case all three assemblies must be joined prior to operation The three assemblies are joined by simply sling each smaller tube inside of the next largest tube and then using the attached pins to secure the sections in place Refer to parts list above if replacement parts are required Replacement parts can be ordered from the T A Pelsue Company at 800 52...

Страница 9: ...1 Product Manual Model TFAT 11A TELESCOPIC FALL ARREST TOWER Revision 01 Date 04 29 2010 Page 9 Figure 3 1 TFAT 11A Label Locations 1 2 3 4 1 500971 001 2 500234 001 3 500972 001 4 500973 001 3 1 Label Locations ...

Страница 10: ...ty and operating practices while using the system Remember you are the key to safety Good safety practices not only protect you but also the people around you Make these practices a working part of your safety program Be certain that everyone operating this equipment is familiar with the procedures recommended and follows safety precautions Remember most accidents can be prevented Do not risk inju...

Страница 11: ...d know how to use it 5 Provide a fire extinguisher for use in case of an accident Store in a highly visible place 6 Install and properly secure all guards and shields before operating 7 Wear appropriate protective gear This list includes but is not limited to A hard hat Protective shoes with slip resistant soles Heavy gloves Protective clothing Face Protection 8 Review and follow the Pre Operation...

Страница 12: ... the area around the work site Untrained operators are not qualified to operate the equipment Many features incorporated into this equipment are the result of suggestions made by customers like you Read this manual carefully to learn how to operate install the equipment safely and as intended By following the operating instructions in conjunction with a good maintenance program your product will p...

Страница 13: ...g this piece of equipment should be familiar with these procedures WARNING The user must ensure that the structure to which the tower base is installed is capable of withstanding the weight of the system combined with the system proof loads in order to retain the stated compliance of the entire system WARNING The user must ensure that the tower system is properly installed completely vertical in o...

Страница 14: ... rotates freely about the tower and does not appear damages e All hardware Pins Leveling Screws have not been damaged and are in working condition 5 1 Product Description Capabilities continued 5 2 Product Installation Set up Figure 5 2a TFAT 11A Pre Operation Inspection Points 310 LB 140 6 kg Maximum User Weight Additional Requirements Notes The TFAT 11A Series Fall Arrest Tower must be set on a ...

Страница 15: ... Plumb the TFAT 11A using the levelling pegs Refer to Fig 5 2c so that the structure is vertical and perpen dicular to the intended working surface 5 2 Product Installation Set up continued Figure 5 2c TFAT 11A Tower Vertical and Secured to Structure Figure 5 2b TFAT 11A Base Pin WARNING The Model TFAT 11A must be plumbed vertically prior to the attachment of any lifeline The TFAT 11A is only appr...

Страница 16: ...rom the tower and grasp the upper round tub with both hands The upper tube can then be lifted to its upper most position and then the locking pin re inserted thereby locking the upper assembly in place Next remove the lower locking pin and grasp the middle square tube with both hands and then lift to its highest position then reinsert the locking pin NOTE It will likely be easier to attach the lif...

Страница 17: ... Figure 5 2e TFAT 11A Installed secured at its maximum elevation 5 2 Product Installation Set up continued WARNING The model TFAT 11A is only approved for the attach ment of a single lifeline for a user of a maximum of 310 LBS WARNING Each of the two sectional locking pins as well as the base securing must be secured through the structure prior to usage of the system The Base securing pin must pro...

Страница 18: ...spection MAINTENANCE INSPECTION 6 0 Maintenance Inspection 1 Read understand and follow the Product Manual and all information located on the product before using maintain ing or inspecting the equipment 2 ANSI and OSHArequire a regular inspection program for all fall arrest equipment and to maintain documented results of these inspections Follow the inspection procedure contained in this manual a...

Страница 19: ...ge the unit should be removed from service and returned to the factory for evaluation and possible repair If there is any question as to the structural integrity of the product remove form service immediately and await further evaluation by a qualified organization or individual Pay special attention to weld locations look for cracks or separation at the welds Keep in mind that the powder coating ...

Страница 20: ...g Screws Overall Structure Notes Place a check in the box if item is acceptable place an x X in the box if item requires maintenance or repair Model Number Serial Number Date Purchased TFAT 11A Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign ...

Страница 21: ...010 Page 21 6 3 Inspection Log continued Date Labels Pins Fasteners Leveling Screws Overall Structure Notes Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign ...

Страница 22: ... on the frame and labels 2 Perform a complete inspection of the unit and document the results prior to storage 3 Oil or grease hinges and moving components in order to prevent corrosion 4 A TFAT 11A series system can be dismantled for storage if desired follow the reverse of the steps given for assembly in section 3 0 of this manual 7 0 Storage 8 0 Contact Information For More Information T A Pels...

Страница 23: ... 500615 001 Product Manual Model TFAT 11A TELESCOPIC FALL ARREST TOWER Revision 01 Date 04 29 2010 Page 23 ...

Страница 24: ...ISO 9001 Certified T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Toll free 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ...

Отзывы: