background image

P/N UM2101KL_2101KG_REV20181128

 

ASSEMBLY INSTRUCTIONS (CONT.) 

5.  Pull forward on the side handrails to tip 

the scale and gently place it face down 
on the floor. Grasp the load cell cable 
protruding from the bottom of the 
platform and feed it through the 
protective metal shield. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

6.  Plug the load cell cable into the load cell 

port located on the back of the platform. 
Pull the excess cable through the top of 
the center handrail.

 

 
 
 
 
 
 
 
 
 
 
 
 

7.  Thread the four feet into the underside 

of the platform. Each foot should be 
completely hand tightened then back the 
feet out 1-½ full turns. This allows for 
proper load cell operation. Carefully tilt 
the scale back to an upright position on 
the floor.

 Warning: Do not drop scale, 

as this can permanently damage the 
load cells. 

Adjust the feet to level the 

scale. Be certain that the feet are not 
completely tightened into the platform. 

 
 
 
 
 
 
 
 
 
 
 
 
 

8.  Obtain the display head and align the 

four holes on the back of the display 
head with the four mounting holes on 
the silver display support. Using the four 
included M4 0.7 x 10mm screws (Part 
E), fasten the display head onto the 
display support using a Phillips head 
screwdriver to tighten the screws.

 

 
 
 
 
 
 
 
 
 
 
 

 
 

Ensure that the 

spacer spring is on 

the bolt of the foot 

before inserting into 

the platform. 

Содержание Health O Meter Professional weigheasier 2101KG

Страница 1: ...2101KL_2101KG_REV20181128 2101KL 2101KG Digital Platform Scale User Instructions PELSTAR LLC 9500 West 55 th St McCook IL 60525 7110 USA www homscales com Pelstar LLC 2018 Equipped with Everlock E112697 0459 ...

Страница 2: ...y Disposal 5 Assembly Instructions 6 Set Up Instructions 10 Everlock Instructions 14 Operating Instructions 15 Maintenance and Cleaning 21 Calibration 22 Troubleshooting 24 Warranty 25 Note This scale has been factory calibrated and does not require calibration prior to use Please register your scale for warranty coverage at www homscales com product support technical support product warranty regi...

Страница 3: ...serious safety hazard Prior to using this scale inspect the AC adapter cord for cracking fraying or for broken bent plug prongs Prior to using this scale ensure that the AC adapter is plugged into an outlet with the rated voltage appropriate for operation Ensure that the AC adapter outlet is wired to a circuit breaker or other protected power source Unplug the AC adapter and carefully store both t...

Страница 4: ... kg x 0 1 kg Power Requirements 100 240V AC 50 60Hz to 9V DC Adapter Type UE15WCP1 9 VDC 500 mA Item ADPT30 included or 6 D batteries not included Environmental Operating temperatures 50 F to 95 F 10 C to 35 C Storage temperatures 30 F to 125 F 0 C to 50 C Maximum Humidity 85 RH Physical Dimensions Platform Length 22 559mm Width 26 660mm Height 2 3 8 60mm Assembled Size Length 27 686mm Width 31 78...

Страница 5: ... o meter Professional Scales Technical Support available during normal business hours at 1 800 638 3722 Scale Disposal This Health o meter Professional scale must be disposed of properly as electronic waste Follow the national regional or local regulations which apply to you for disposal of electronic waste or batteries Do not dispose of this device in the domestic waste stream Pelstar LLC has bee...

Страница 6: ...knife scissors or any sharp object to open the protective inner packaging Parts List 1 Brown box containing 1 Box containing the AC adapter 1 Display Head 1 User Information 1 White box containing o 4 Feet o 1 AC adapter holder o 1 4mm Allen wrench o 1 5mm Allen wrench o 1 8mm Allen wrench o 1 Plastic bracket cover o Hardware for assembly A M10 1 5 x 40mm bolts Qty 2 B M8 1 25 x 20mm bolts Qty 16 ...

Страница 7: ...sure not to pinch the cable Place the eight M8 washers Part F onto the eight M8 1 25 x 20mm bolts Part B and insert into the mounting holes on the scale base lightly tighten using the included 5mm Allen wrench Do not over tighten 3 Align the left and right side handrails with the mounting holes in the platform Place the remaining eight M8 washers Part F onto the remaining eight M8 1 25 x 20mm bolt...

Страница 8: ...htened then back the feet out 1 full turns This allows for proper load cell operation Carefully tilt the scale back to an upright position on the floor Warning Do not drop scale as this can permanently damage the load cells Adjust the feet to level the scale Be certain that the feet are not completely tightened into the platform 8 Obtain the display head and align the four holes on the back of the...

Страница 9: ... the scale as shown 12 Obtain the handle and align it with the ends of the side handrails Insert the two medium M6 1 0 x 10mm bolts Part C into the holes on the underside of the handle Using the included 4mm Allen wrench attach the handle to the center handrail The handle should be attached with the Warning label facing up Scale assembly is complete See Powering the Scale on page 10 for battery AC...

Страница 10: ... of the display head by unscrewing the battery cover screw 2 Remove the battery pack from the display head Replace or install fresh batteries making sure to install them in the proper direction Health o meter Professional recommends using an alkaline battery rated for 130 F 54 C operation Do not use Zinc Carbon batteries 3 Re insert the battery pack into the display head ensuring the end with the ...

Страница 11: ... a date code lower than 1918 If the scale is locked per the instructions above users can still view the alternate weight measuring unit by enabling the Unit View option Enabling the Unit View option allows the user to press the Unit button to briefly display the weight in the alternate weight measuring unit After releasing the Unit button the display will return to the locked weight measuring unit...

Страница 12: ...et the preferred time of inactivity before power off 1 Press to access the Help menu options 2 While in the Help menu press to select Set Options Press to advance to the next menu 3 While in the Set Options sub menu press to scroll through the options until AC Auto Off is highlighted in red 4 Press to change the AC Auto Off option Choose Enable for the display to turn off after a period of inactiv...

Страница 13: ...o find a zero when powered on rather it will use the last zero setting it had from its most recent use There will be no delay in using the scale if the Auto Zero is disabled Health o meter Professional recommends that if the Disable option is selected users should manually zero the scale before each weight measurement by pressing Users will see dashes appear on the screen as the scale is finding z...

Страница 14: ...ssional Scales Customer Service at 1 800 815 6615 1 Press to access the Help menu options 2 While in the Help menu press to select Set Options Press to advance to the next menu 3 While in the Set Options sub menu press to scroll through the options until Everlock is highlighted in red 4 Press to begin the Everlock procedure To exit the procedure without engaging Everlock press 5 The screen will pr...

Страница 15: ...s prompts entry of a weight value to be deducted from the weight on the platform Also releases tare weight returns display to zero Toggles between pounds and kilograms If weight measuring unit is locked and Unit View setting is enabled press and hold Unit button to briefly display the alternate weight measuring unit Note The Unit button is disabled on KG models or on KL models with Everlock engage...

Страница 16: ...held on the display by pressing The scale will continue to display the patient s weight after they step off the scale and will remain on the display until released or the scale is powered off To release press 4 To reweigh the patient without having them step off of the scale press 5 To see the patient s weight in another unit of measurement press and hold down If the scale is in LB mode it will co...

Страница 17: ...t on the scale it may take several seconds for the scale to lock onto the weight 3 After obtaining the patient s weight and with the patient remaining on the scale press 4 The scale will prompt entry of the patient s height Use the arrow keys to enter the patient s height Note When weighing in pounds the height is displayed in inches When weighing in kilograms the height is displayed in centimeter...

Страница 18: ...atically deduct the tared weight of the object from the gross weight of the patient and object together The display will show the patient s weight 5 With no weight on the scale the display will show the tare value as a negative amount The tare value will remain on the display until changed cleared or until the scale is powered off 6 The weight may be held on the display by pressing The scale will ...

Страница 19: ...ight of the patient The display will show the patient s weight 5 The weight may be held on the display by pressing The scale will continue to display the patient s weight after they step off the scale and will remain on the display until released or the scale is powered off To release press 6 To reweigh the patient without removing them from the scale press 7 To see the patient s weight in another...

Страница 20: ...ay along with the parent s tared weight 4 Carefully place the child into the parent s arms The scale will automatically deduct the weight of the parent and only display the child s weight Note For an alternate method after taring the parent s weight in step 3 have the parent step off of the scale With no weight on the scale the display will show the tare value as a negative amount Have the parent ...

Страница 21: ... unit 1 Health o meter Professional recommends using one of the following cleaning solutions on a soft cloth or disposable wipe mild soap and water solution 70 isopropyl alcohol solution with 1 5 hydrogen peroxide concentration After cleaning wipe with a cloth dampened with water and then with a clean dry cloth To avoid residue build up or damp surfaces ensure the screen and scale parts are comple...

Страница 22: ...nit of measure Note Only weights certified and traceable to national standards should be used for calibration Warning Always ensure that the scale is returned to the correct UOM after scale calibration 1 Press to access the Help menu options 2 While in the Help menu press to select Calibrate Press to advance to the next step 3 The display will prompt for entry of the password Press the following k...

Страница 23: ...rompt for the calibration weights to be placed on the platform Press after calibration weights are placed on the platform 9 The display will show Calibrating during the calibration process 10 If calibration is successful the display will show Calibration Complete with a 4 digit calibration count 11 If calibration is unsuccessful the display will show an error message that the entered calibration w...

Страница 24: ...r Tighten the feet on the underside of the platform to ensure all 4 feet are properly balanced 4 Scale is out of calibration 4 Check weight with known weight value Weighing is performed but the weighing process takes too long and the weight does not lock on the display The patient is not sitting or standing still Ask the patient to stand still The battery icon on the display indicates that the bat...

Страница 25: ... and you may also have other rights that vary from country to country state to state province to province or jurisdiction to jurisdiction To get Warranty Service make sure you keep your sales receipt or document showing proof of purchase Call 1 800 638 3722 or 1 708 377 0600 to receive a return authorization RA number which must be included on the return label Attach your proof of purchase to your...

Отзывы: