PV 100a
the burner. The external auger has stopped, the internal feeder and fan are still
working until all fuel is burned.
END BLOW
When photocell doesn`t see any flame only the fan keeps on working with
minimum speed in order to make sure there is no fuel in burner.
NO PELLETS
Level sensor does not detect pellets
NO FLAME
There is no flame in the burner more than 120 seconds during burning.
OVERHEAT
Temperature in the burner has reached preset temperature and burner turned off.
IGN.ERROR
Flame is not recognized after ignition
LEVEL ERR
Level dose not reached or level dose not disappear at burning time
FEEDER ERR
Jam in feeder or feeder rotation is not detected
FAN ERROR
Fan rotation problem
GRATE ERROR
Grate is stucked.
BATTERY LOW
Battery is not connected or empty
NO POWER
Supply power is not detected – burner works on battery
Settings
To enter settings menu, press OK. To go back to log screen, press “ESC”.
Table 5 Main menu
Men
u nr
Menu
parameter ENG
Description
Default
value
Selection list
1
STATUS->
Submenu for status information *
1
2
INFO->
Information from burner devices *
2
3
BURNER
Turn burner ON/OFF
OFF
ON/OFF
4
HOLD FLAME
Flame holding allowed *
3
OFF
ON/OFF/AUTO
5
PELLETS
Select fuel quality
NORMAL
NORMAL/LIGHT/HEAVY
6
POWER
Actual power level
AUTO AUTO/50/60/70/80/90/100
7
BASE AIR
Fan speed correction for all fan
speeds
0
-2/-1/0/+1/+2/+3/+4/+5
8
LANGUAGE
Language selection *
4
ENG
See language list
9
PARAMETERS -> Parameter setup menu
*1 – see “Status menu description”
*2 – see “Info menu description”
*3 – see “HOLD FLAME” status description
*4 – see “Languages” chapter
24
Содержание PV 100a
Страница 1: ...Pellet burner PV 100a User manual...
Страница 31: ...PV 100a Controller board description Figure 10 Controller board 31...
Страница 34: ...PV 100a 34...