Pelican PAC3/PAC6 Premium Whole House Water Filter &
Advantage Series Salt Free Softener Combo
©
2019
Enviro Water Solutions, Inc.
3060 Performance Circle, Suite 2, DeLand, FL 32724
Page 1
2
www.pelicanwater.com
(877) 842-1635
Install Electronic Head
1. Level the Pelican Softener Tank.
Notice:
If the tank is not level, lift the tank straight up 6 inches and tap it on the ground until the tank stands
vertical. The bottom of the tank is round and the boot allows the tank to stand upright.
2. Determine the size and material of your incoming water supply line and choose the appropriate
fittings required to connect it to the Bypass Valve.
CAUTION:
Do not over-tighten any of the fittings during installation.
3. Remove the grey cap from the top of the Softener tank.
4. Screw the Electronic Head onto the tank hand-tight.
5. Install the appropriate fittings onto the inlet and outlet, following the labels on the Head.
6. Connect the incoming water supply to the fitting on the inlet side of the Bypass Valve.
7. Connect the outgoing water supply to the outlet side of the Bypass Valve.
8. Firmly press one end of the PVC Tubing Drain Line onto the drain line barb, and secure the other
end of the line to a drain.
MENU
SET
Whole House
Salt Softener
Tank Installation
CAUTION:
Do not over-tighten any of the fittings during installation.
Table 2: Bypass Valve Fittings
Part
Description
Qty.
1" PVC Tail Adaptor for
Electronic Head Bypass
2
Clip Channel
O-Ring
Electronic Head
Bypass Valve
Tail Adaptor
s
Red Clips
Distributor Tube
Rev B