GB 10
Controls
Switching on the grease saturation indicator for the activated
carbon filter
Switch off the extractor hood and press and hold the
(1) and
(4) buttons simultaneously for 3 seconds.
The L1 and L2 indicators will start to flash for 5 seconds.
Switching off the grease saturation indicator for the activated
carbon filter
Switch off the extractor hood and press and hold the
(1) and
(4) buttons simultaneously for 3 seconds.
The L1 indicator will start to flash for 2 seconds.
Thermal cut-out
The hood is supplied with a temperature sensor that switches the motor
to speed 3 if the temperature near the controls becomes too hot.
This is indicated by the L1, L2, L3 indicators that start flashing.
This situation will continue until the temperature has dropped to a safe
level. To exit this mode press the
(1) or
(2) key.