EN 22
Technical data
On the label on the bottom of this equipment, you will find the total
wattage, the required voltage and the frequency.
Gas information
Burners
Country
Gas
Normal pressure
mbar
Nominal heat input (W)
N°
Description
Min.
Max.
1
Semi-rapid
(lowered)
BE
NL
BE
NL
G20
G25
G30/G31
G30/G31
20
25
28-30/37
30
550
550
550
550
1400
1400
1350
1350
2
Semi-rapid
BE
NL
BE
NL
G20
G25
G30/G31
G30/G31
20
25
28-30/37
30
550
550
550
550
1750
1750
1750
1750
3
Rapid
BE
NL
BE
NL
G20
G25
G30/G31
G30/G31
20
25
28-30/37
30
800
800
800
800
2800
2800
2800
2800
4
Simmer
BE
NL
BE
NL
G20
G25
G30/G31
G30/G31
20
25
28-30/37
30
450
450
450
450
1000
1000
1000
1000
5
Wok GK575
(4 kW)
BE
NL
BE
NL
G20
G25
G30/G31
G30/G31
20
25
28-30/37
30
1800
1800
1800
1800
4000
4000
4000
4000
Wok GKT595
(3,8 kW)
BE
NL
BE
NL
G20
G25
G30/G31
G30/G31
20
25
28-30/37
30
1800
1800
1800
1800
3750
3750
3800
3800
Wok GK595
(5 kW)
BE
NL
BE
NL
G20
G25
G30/G31
G30/G31
20
25
28-30/37
30
1800
1800
1800
1800
5000
4750
4750
4750
Appliance
Country
Category
Total heat input
GK564ONYA
NL
II2L3B/P
G25: 6,95 kW - G30: 505 g/h - G31: 496 g/h
GK564ONYB
BE
II2E
+
3
+
G20: 6,95 kW - G30: 505 g/h - G31: 496 g/h
GKT564ONYA
NL
II2L3B/P
G25: 6,95 kW - G30: 505 g/h - G31: 496 g/h
GK575ONYA
NL
II2L3B/P
G25: 10,95 kW - G30: 796 g/h - G31: 782 g/h
GK575ONYB
BE
II2E
+
3
+
G20: 10,95 kW - G30: 796 g/h - G31: 782 g/h
GK595ONYA
NL
II2L3B/P
G25: 11,95 kW - G30: 869 g/h - G31: 854 g/h
GK595ONYB
BE
II2E
+
3
+
G20: 11,95 kW - G30: 869 g/h - G31: 854 g/h
GKT595ONYA
NL
II2L3B/P
G25: 10,70 kW - G30: 778 g/h - G31: 764 g/h
INSTALLATION