10. Functions for the PEHA
single-switch and Easywave
wireless attachment
10.1 Function selector switch - position 1
"Tactile switch"
10.2 Function selector switch - position 2
"Momentary contact"
10.3 Function selector switch - position 3
"Stairwell switch"
10.4 Function selector switch - position 4
"Time switch, short-term"
10.5 Function selector switch - position 5
"Time switch, long-term"
10.6 Function selector switch - position 6
"Time switch, programmable"
Programming a new switching period:
a) The light is off
After pressing the button for about 3 s the light will switch on;
the new time period to be programmed begins to accumulate.
For switches with an LED, the LED will begin to blink.
b) The light is on
After pressing the button for about 3 s the light will switch off
and the expired time will be stored.
For a switch with LED, the LED will cease to blink.
Maximum programmable time..............................17 hours
0 to 2 minutes........................................exact to the second
2 minutes to 2 hours...............................exact to the minute
2 hours to 17 hours....................................exact to the hour
11. PEHA double-switch
functions
11.1 Function selector switch - position 1
"Tactile switch"
12. Functions of the PEHA Infrared
attachment and remote control
Only one remote control unit can be used for
a given FM module with infrared attachment.
When the remote control unit is used for the first time its
basic
level
(level 0) and
Group 1
are active.
To use another level (1 ... 6) in the remote control unit, the infrared
address for the remote control unit must be stored in the FM
module. This is done by holding down the attachment's button
continuously
. Once the attachment's LED begins to blink, the
desired level button (1 ... 6) must be pressed and thereafter one
of the function buttons
"On/Off - UP
U
U
U
U
U
- Down
V
V
V
V
V
"
.
The LED will stop blinking when a correct IR telegram has been
received; thus storing the IR address in a non-volatile memory.
After this procedure has been completed the button on the
attachment can be released.
12.1 Function selector switch - position 1
"Tactile switch"
12.2 Function selector switch - position 2
"Momentary contact"
12.3 Function selector switch - position 3
"Time switch, short-term"
12.4 Function selector switch - position 4
"Time switch, long-term"
Tactile attachment,
remote station
Function
Press button briefly/release Switch on/off
Function pot.
(see Point 9)
Potentiometer function 1
Tactile attachment,
remote station
Function
Press button
Switch on
Release button
Switch off
Function pot.
(see Point 9)
Potentiometer function 1
Tactile attachment,
remote station
Function
Press button briefly
then release it
Switch on for the preset
period or to restart period!
Function pot.
(s. Point 9) Potentiometer function 2
Function LED
(attachment)
Orientation light!
No premature switch-off
possible!
Tactile attachment,
remote station
Function
Press button briefly
then release it
Switch on for the preset
period or to switch off!
Function pot.
(s. Point 9) Potentiometer function 2
Function LED
(attachment)
Orientation light! Premature
switch-off possible!
Tactile attachment,
remote station
Function
Press button briefly
then release it
Switch on for the preset
period or to switch off!
Function pot.
(s. Point 9) Potentiometer function 3
Function LED
(attachment)
Orientation light! Premature
switch-off possible!
Tactile attachment,
remote station
Function
Press button briefly
then release it
Switch on for the preset
period or to switch off!
Function LED
(attachment)
Orientation light! Premature
switch-off possible!
Remote station
Function
Press button briefly then release it Switch on/off
Tactile attachment
Function
Press the left button briefly
Switch off
Press the right button briefly
Switch on
IR cover, remote station
Function
Press button briefly then release it Switch on/off
Remote control unit
Function
On/Off - UP
U
- Down
V
press briefly
Switch on/off
LED function
(attachment)
LED lights upon receipt of an
IR telegram.
Premature switch-off possible!
IR cover, remote station
Function
Press button
Switch on
Release button
Switch off
Remote control unit
Function
On/Off - UP
U
- Down
V
press
Switch on
On/Off - UP
U
- Down
V
release Switch off
LED function
(attachment)
LED lights upon receipt
of an IR telegram
IR cover, remote station
or remote control
Function
Press button briefly
then release it
Switch on for the preset
period or to switch off!
Function pot.
(see Point 9)
Potentiometer function 2
Function LED
(attachment)
LED lights upon receipt
of an IR telegram!
IR cover, remote station
or remote control
Function
Press button briefly
then release it
Switch on for the preset
period or to switch off!
Function pot.
(see Point 9)
Potentiometer function 3
Function LED
(attachment)
LED lights upon receipt
of an IR telegram!
13. PEHA motion sensor
functions
Setting switched-on time
and the ambient-light threshold:
The setting for switched-on time is made with the motion sensor's
adjustable potentiometer for switch-on period. The setting for
ambient-light threshold is made with the motion sensor's
adjustable potentiometer for ambient-light value.
13.1 Function selector switch - position 1
"Motion sensor"
In the event that both timers are running (switched-on time
in both the motion sensor and its remote station) the relay
unit will be switched off by the timer which expires last.
13.2 Function selector switch - position 2
"Multi-master motion sensor"
Multi-Master:
Another local motion sensor will also respond when the ambient-
light value has not been reached by the switched-on light.
Caution:
A minimum load of at least 25 W must be maintained!
Operating multiple units in parallel:
The setting for switched-on time is made with the given motion
sensor's adjustable potentiometer for switch-on period. The setting
for ambient-light threshold is made with the given motion sensor's
adjustable potentiometer for ambient-light value.
Remote station input:
The remote station input controls the switched line.
13.3 Function selector switch - position 3
"Motion sensor without continuous light button"
The button for continuous light will be deactivated after about 1 min.
Functions of the remote station and pot.:
See 13.1, Function selector switch - position 1
Remote station
Function
Press button briefly
then release it
Switch-on for the preset
illumination period
Illumination period
(rem. station)
1 ... 60 minutes
Potentiometer
(see Point 9)
Potentiometer function 4