INSTALLING THE OUT-OF-ROOM ALARM CONTROL UNIT 

1.

Undo the 4 closure screws on the front panel.

2.

Use the three existing holes to fix the box back panel to

the wall: use three screws of a length suitable for the
thickness of the wall to which the panel will be attached. Fit a
rubber washer (supplied) between each screw and the box
backing.

Make all the electrical connections as illustrated in the diagram for the corresponding 
model (see relative table in APPENDICES). To effect correct electrical connection 
and maintain the protection rating, use appropriate wire/raceway grips to ensure a 
good seal. Route the wiring inside the unit in as tidy a fashion as possible: be 
especially careful to keep power wires away from signal wires. Use clips to hold wires in place. 

3.

Re-close the front panel, making sure that all the wires are inside

the box and that the box seal sits in its seat properly.
Tighten the front panel using the 4 screws, making sure the
O-rings on the head of each screw are used.

CHAPTER 2: INSTALLATION 

CHAP. 2 - Installation 

2.1

- ENG -

USE AND MAINTENANCE MANUAL

 

Содержание 6CIAPE03

Страница 1: ...Alle Angaben sind ohne Gew hr nderungen bleiben CI GmbH CONTROL INSTRUMENTS vorbehalten V 2201 001 manual ECP APE 03...

Страница 2: ...HBUTTON UNIT Page 3 1 6 IDENTIFICATION DATA Page 4 1 7 DESCRIPTION OF SYSTEM INSTALLATION Page 5 2 1 INSTALLING THE OUT OF ROOM ALARM CONTROL UNIT Page 6 2 2 INSTALLING THE IN ROOM EMERGENCY PUSHBUTTO...

Страница 3: ...n mains power 20 mA Buffer battery 12 V DC Ni MH 1300 mAh Complete recharge time 110 h Operating autonomy With 230 V AC NOT ON running on charged buffer battery 14 h approx With 230 V AC power ON unli...

Страница 4: ...IFICATION DATA The unit described in this manual has on its side an ID plate showing all the relevant identification data Name of Manufacturer Code and model of UNIT electrical board Serial number IP...

Страница 5: ...mushroom type button with N C contact The pushbutton is permanently lit by LEDs so that it can be located in the dark Acoustic visual alarm control unit to be fitted outside the cold room Features a s...

Страница 6: ...ng model see relative table in APPENDICES To effect correct electrical connection and maintain the protection rating use appropriate wire raceway grips to ensure a good seal Route the wiring inside th...

Страница 7: ...nous warning devices on the external alarm control unit The auxiliary relay contact closes To deactivate the alarm pull out the emergency illuminated push button again unlock In the event of a 230 V A...

Страница 8: ...TTACHMENT SCREWS 4 BUFFER BATTERY SUPPORT FIXING SCREWS 5 BOARD 6 BUFFER BATTERY SUPPORT METAL SHEETING 9 FRONTAL SECTION IN ABS 10 ACOUSTIC VISUAL ALARM 11 BOX CLOSURE SCREWS 12 ACOUSTIC VISUAL ALARM...

Страница 9: ...ions have been made it is therefore necessary to connect this fastom to the connector marked 1 on the upper left side of the board as also indicated on the wiring diagram It is advisable to first conn...

Страница 10: ...r internal components or any work carried out in a way that fails to comply with the information instructions in this manual shall render the warranty null and void immediately Modifications improper...

Страница 11: ...I DELLE SEGUENTI NORME comprese tutte le modifiche THE CONFORMITY WITH THE REQUIREMENTS OF THIS DIRECTIVE IS TESTIFIED BY COMPLETE ADHERENCE TO THE FOLLOWING STANDARDS including all amendments Norme a...

Страница 12: ...CI GmbH CONTROL INSTRUMENTS Baumschulenweg 10 70736 Fellbach DE www ci gmbh com info ci gmbh com 49 711 65883 0...

Отзывы: