Pego 6CIAPE03 Скачать руководство пользователя страница 2

6CI

APE03

 

Pag.

1

 

 

Rev. 1-12

 

INTRODUCTION 

Page  

2

 

1.1 

MAN IN COLD ROOM ALARM KIT COMPONENTS

 

Page  

2

 

1.2 

PRODUCT IDENTIFICATION CODES

 

Page  

2

 

1.3 

TECHNICAL CHARACTERISTICS

 

Page  

3

 

1.4 

DIMENSIONS OF ALARM CONTROL UNIT

 

Page  

3

 

1.5 

DIMENSIONS OF EMERGENCY PUSHBUTTON UNIT

 

Page  

3

 

1.6 

IDENTIFICATION DATA

 

Page  

4

 

1.7 

DESCRIPTION OF SYSTEM

 

INSTALLATION 

Page  

  5

 

2.1 

INSTALLING THE OUT-OF-ROOM ALARM CONTROL UNIT

 

Page    

6

 

2.2 

INSTALLING THE IN-ROOM EMERGENCY PUSHBUTTON UNIT

 

Page    

6

 

2.3 

OPERATION AND MAINTENANCE

 

Page    

7

 

2.4 

EXPLODED DIAGRAM

 

Page    

8

 

2.5 

ELECTRICAL CONNECTIONS

 

 

Page    

9

 

2.6 

WARRANTY TERMS

 

APPENDICES 

Page    

10

 

A.1

EC DECLARATION OF CONFORMITY

 

CONTENTS 

CHAP. 1 

CHAP. 2 

ENGLISH

- ENG -

USE AND MAINTENANCE MANUAL

 

Содержание 6CIAPE03

Страница 1: ...Alle Angaben sind ohne Gew hr nderungen bleiben CI GmbH CONTROL INSTRUMENTS vorbehalten V 2201 001 manual ECP APE 03...

Страница 2: ...HBUTTON UNIT Page 3 1 6 IDENTIFICATION DATA Page 4 1 7 DESCRIPTION OF SYSTEM INSTALLATION Page 5 2 1 INSTALLING THE OUT OF ROOM ALARM CONTROL UNIT Page 6 2 2 INSTALLING THE IN ROOM EMERGENCY PUSHBUTTO...

Страница 3: ...n mains power 20 mA Buffer battery 12 V DC Ni MH 1300 mAh Complete recharge time 110 h Operating autonomy With 230 V AC NOT ON running on charged buffer battery 14 h approx With 230 V AC power ON unli...

Страница 4: ...IFICATION DATA The unit described in this manual has on its side an ID plate showing all the relevant identification data Name of Manufacturer Code and model of UNIT electrical board Serial number IP...

Страница 5: ...mushroom type button with N C contact The pushbutton is permanently lit by LEDs so that it can be located in the dark Acoustic visual alarm control unit to be fitted outside the cold room Features a s...

Страница 6: ...ng model see relative table in APPENDICES To effect correct electrical connection and maintain the protection rating use appropriate wire raceway grips to ensure a good seal Route the wiring inside th...

Страница 7: ...nous warning devices on the external alarm control unit The auxiliary relay contact closes To deactivate the alarm pull out the emergency illuminated push button again unlock In the event of a 230 V A...

Страница 8: ...TTACHMENT SCREWS 4 BUFFER BATTERY SUPPORT FIXING SCREWS 5 BOARD 6 BUFFER BATTERY SUPPORT METAL SHEETING 9 FRONTAL SECTION IN ABS 10 ACOUSTIC VISUAL ALARM 11 BOX CLOSURE SCREWS 12 ACOUSTIC VISUAL ALARM...

Страница 9: ...ions have been made it is therefore necessary to connect this fastom to the connector marked 1 on the upper left side of the board as also indicated on the wiring diagram It is advisable to first conn...

Страница 10: ...r internal components or any work carried out in a way that fails to comply with the information instructions in this manual shall render the warranty null and void immediately Modifications improper...

Страница 11: ...I DELLE SEGUENTI NORME comprese tutte le modifiche THE CONFORMITY WITH THE REQUIREMENTS OF THIS DIRECTIVE IS TESTIFIED BY COMPLETE ADHERENCE TO THE FOLLOWING STANDARDS including all amendments Norme a...

Страница 12: ...CI GmbH CONTROL INSTRUMENTS Baumschulenweg 10 70736 Fellbach DE www ci gmbh com info ci gmbh com 49 711 65883 0...

Отзывы: