background image

This drawing is to scale 

and can be used as a template if necessary

Care & Maintenance

To maintain the surface finishes, simply wipe occasionally with a mild detergent on soft damp 
cloth. Dry using soft cloth, never use abrasive cleaners or chemical household cleaners, 
avoid contact with concentrated bleach.

Pegler products are manufactured to the highest standards and should require little or no 
maintenance. In the unlikely event of any spare part requirements, please visit our website: 
www.pegler.co.uk, contact you’re nearest stockist or the Pegler Yorkshire Technical Office 
on telephone 0870 1200285.

Содержание 341105

Страница 1: ...of PERFORMA Electronic Self Closing Fittings Mains Powered Pegler Limited St Catherine s Avenue Doncaster DN4 8DF Telephone 01302 560560 Fax 01302 560109 Pegler Yorkshire Technical Office Tel 0870 120...

Страница 2: ...y for on site requirements Once movement is detected within its range the flow of water will commence When water usage is finished move away and the flow of water will cease Please Note All Pegler Yor...

Страница 3: ...ver be extended Solenoid valve 6V bi stable latching Connection to control module is via 2 spade connectors Control Module Transformer Primary 230 240 AC 50Hz Max 11mA Fuses Primary 63mA quick blow Co...

Страница 4: ...lters are supplied with the products it is the responsibility of the installer to ensure that they are fitted upstream Failure to do so will void warranty To reduce pressure to a more optimum level we...

Страница 5: ...support a safe delivery of water 1 Determine the position of the basin tap allowing sufficient space around the tap for it to be used without hindrance or harm to the user 2 Fit tap through hole in wa...

Страница 6: ...ap are positioned through the hole in the wall panel Tighten backnut behind wall panel 3 Route supply pipework to point where solenoid valve is being fitted then flush pipework thoroughly Please Note...

Страница 7: ...the hole in the wall panel or worktop Tighten backnut behind wall panel or worktop 3 Route supply pipework to point where solenoid valve is being fitted then flush pipework thoroughly Please Note For...

Страница 8: ...to do so Please Note When used in a showering application and therefore the dip switch 3 is turned on for the near and far feature at the point of first switching on the shower the sensor needs to be...

Страница 9: ...me is 10 seconds Turning clockwise will increase the distance while anticlockwise will reduce The screw will turn to a maximum 225 degrees rotation DO NOT FORCE THE SCREW FURTHER Troubleshooting Probl...

Страница 10: ...WITCHED OFF BEFORE DISCONNECTING SOLENOID Swap polarity of battery to spade terminals to open solenoid and match polarity of battery to spade terminals to close solenoid Unit will click open and close...

Страница 11: ...cloth never use abrasive cleaners or chemical household cleaners avoid contact with concentrated bleach Pegler products are manufactured to the highest standards and should require little or no mainte...

Страница 12: ...Limited St Catherine s Avenue Doncaster DN4 8DF Telephone 01302 560560 Fax 01302 560109 Pegler Yorkshire Technical Office Tel 0870 1200285 This drawing is to scale and can be used as a template if nec...

Отзывы: