Problem
8 Hour Autoflush feature is required
Remedy
• Switch on dip switch #1
Problem
Splashes when in operation
Remedy
• Fit an aerator rather than flow straightener.
• Reduce supply pressure to fitting
Problem
No Flow (Power Test)
Remedy
•
THIS OPERATION SHOULD ONLY BE UNDERTAKEN BY
QUALIFIED PERSONEL.
To test solenoid check power supply is
on (Note: red LED will glow red inside control module box if mains
power is being supplied) I red LED is not on – please turn off mains
power and check 63mA quick blow fuse and connecting cables.
•
CAUTION PLEASE ENSURE POWER SUPPLY IS SWITCHED
OFF.
Check cable continuity and is not damaged.
• If non of the above solve the no flow problem please contact Pegler
Yorkshire Technical Office on telephone 0870 1200285
Problem
No Flow (Solenoid Test)
Remedy
• If above test is positive with glowing LED, next test solenoid using a
9 volt battery (dab on/ dab off with battery).
CAUTION PLEASE
ENSURE POWER SUPPLY IS SWITCHED OFF BEFORE
DISCONNECTING SOLENOID.
Swap polarity of battery to spade
terminals to open solenoid and match polarity of battery to spade
terminals to close solenoid. Unit will click open and close if
functioning.
• Check solenoid is correct way around (direction arrow on solenoid
body)
• If non of the above solve the no flow problem please contact Pegler
Yorkshire Technical Office on telephone 0870 1200285
Problem
No Flow, Product is not picking up movement (Sensor Test)
Remedy
•
THIS OPERATION SHOULD ONLY BE UNDERTAKEN BY
QUALIFIED PERSONEL.
To test IR sensor is fully operational
check power supply is on. Remove control module box lid, turn on
dip switch #2 (Note: yellow LED will flash inside electronics box if unit
is functioning) Wave hand in front of IR sensor at a distance at
approximately 100mm (10cm). Yellow LED should no glow solid
yellow.
• If this does not glow solid yellow turn up sensitivity potentiometer
and try again.
• If non of the above solve the no flow problem please contact Pegler
Yorkshire Technical Office on telephone 0870 1200285.
• If problem is solved switch dip #2 switch back to the off position and
refit lid.