Problem

 

 

8 Hour Autoflush feature is required

Remedy

 

•  Switch on dip switch #1

Problem

 

 

Splashes when in operation

Remedy

 

•  Fit an aerator rather than flow straightener.

   

•  Reduce supply pressure to fitting

Problem

 

 

No Flow (Power Test)

Remedy

 

• 

THIS OPERATION SHOULD ONLY BE UNDERTAKEN BY  

 

   

 

QUALIFIED PERSONEL.

 To test solenoid check power supply is  

   

 

on (Note: red LED will glow red inside control module box if mains  

   

 

power is being supplied) I red LED is not on – please turn off mains  

   

 

power and check 63mA quick blow fuse and connecting cables.

   

• 

CAUTION PLEASE ENSURE POWER SUPPLY IS SWITCHED 

   

 

OFF.

   

 

Check cable continuity and is not damaged.

   

•  If non of the above solve the no flow problem please contact Pegler 

   

 

Yorkshire Technical Office on telephone 0870 1200285

Problem

 

 

No Flow (Solenoid Test)

Remedy

 

•  If above test is positive with glowing LED, next test solenoid using a  

   

 

9  volt  battery  (dab  on/  dab  off  with  battery). 

CAUTION  PLEASE 

   

 

ENSURE  POWER  SUPPLY  IS  SWITCHED  OFF  BEFORE  

   

 

DISCONNECTING SOLENOID.

 Swap polarity of battery to spade  

   

 

terminals to open solenoid and match polarity of battery to spade  

   

 

terminals  to  close  solenoid.  Unit  will  click  open  and  close  if  

   

 

functioning.

   

•  Check solenoid is correct way around (direction arrow on solenoid 

   

 

body)

   

•  If non of the above solve the no flow problem please contact Pegler 

   

 

Yorkshire Technical Office on telephone 0870 1200285

Problem

 

 

No Flow, Product is not picking up movement (Sensor Test)

Remedy

 

• 

THIS  OPERATION  SHOULD  ONLY  BE  UNDERTAKEN  BY 

   

 

QUALIFIED  PERSONEL.

  To  test  IR  sensor  is  fully  operational  

   

 

check power supply is on. Remove control module box lid, turn on 

   

 

dip switch #2 (Note: yellow LED will flash inside electronics box if unit  

   

 

is  functioning)  Wave  hand  in  front  of  IR  sensor  at  a  distance  at 

   

 

approximately  100mm  (10cm).  Yellow  LED  should  no  glow  solid 

   

 

yellow.

   

•  If this does not glow solid yellow turn up sensitivity potentiometer 

   

 

and try again.

   

•  If non of the above solve the no flow problem please contact Pegler 

   

 

Yorkshire Technical Office on telephone 0870 1200285.

   

•  If problem is solved switch dip #2 switch back to the off position and  

   

 

refit lid.

Содержание 341105

Страница 1: ...of PERFORMA Electronic Self Closing Fittings Mains Powered Pegler Limited St Catherine s Avenue Doncaster DN4 8DF Telephone 01302 560560 Fax 01302 560109 Pegler Yorkshire Technical Office Tel 0870 120...

Страница 2: ...y for on site requirements Once movement is detected within its range the flow of water will commence When water usage is finished move away and the flow of water will cease Please Note All Pegler Yor...

Страница 3: ...ver be extended Solenoid valve 6V bi stable latching Connection to control module is via 2 spade connectors Control Module Transformer Primary 230 240 AC 50Hz Max 11mA Fuses Primary 63mA quick blow Co...

Страница 4: ...lters are supplied with the products it is the responsibility of the installer to ensure that they are fitted upstream Failure to do so will void warranty To reduce pressure to a more optimum level we...

Страница 5: ...support a safe delivery of water 1 Determine the position of the basin tap allowing sufficient space around the tap for it to be used without hindrance or harm to the user 2 Fit tap through hole in wa...

Страница 6: ...ap are positioned through the hole in the wall panel Tighten backnut behind wall panel 3 Route supply pipework to point where solenoid valve is being fitted then flush pipework thoroughly Please Note...

Страница 7: ...the hole in the wall panel or worktop Tighten backnut behind wall panel or worktop 3 Route supply pipework to point where solenoid valve is being fitted then flush pipework thoroughly Please Note For...

Страница 8: ...to do so Please Note When used in a showering application and therefore the dip switch 3 is turned on for the near and far feature at the point of first switching on the shower the sensor needs to be...

Страница 9: ...me is 10 seconds Turning clockwise will increase the distance while anticlockwise will reduce The screw will turn to a maximum 225 degrees rotation DO NOT FORCE THE SCREW FURTHER Troubleshooting Probl...

Страница 10: ...WITCHED OFF BEFORE DISCONNECTING SOLENOID Swap polarity of battery to spade terminals to open solenoid and match polarity of battery to spade terminals to close solenoid Unit will click open and close...

Страница 11: ...cloth never use abrasive cleaners or chemical household cleaners avoid contact with concentrated bleach Pegler products are manufactured to the highest standards and should require little or no mainte...

Страница 12: ...Limited St Catherine s Avenue Doncaster DN4 8DF Telephone 01302 560560 Fax 01302 560109 Pegler Yorkshire Technical Office Tel 0870 1200285 This drawing is to scale and can be used as a template if nec...

Отзывы: