Conversion list

Branding

Branding

Adaptor

Pegler Yorkshire

Terrier

Not required

Pegler Yorkshire

Mistral 

Not required

Pegler Yorkshire

Belmont 4 

Not required

Pegler Yorkshire 

Bulldog 

Not required

& Wolseley

Altechnic

Ecocal

Not required

B & Q

Regis

Not required

BSS

BOSS TRV

Not required

Comap

Westhern 5 TRV

AD2

Comap

Senso TRV

AD2

Comap

S2 TRV

AD2

Danfoss

RAS C2

AD1

Danfoss

RAS D2 Revolver

AD1

Danfoss

RLV-D D Pushfit

AD1

Drayton

RT212

Not required

Drayton

RT414

Not required

Drayton

TRV4

Not required

Drayton

TRV3

AD3

Branding

Branding

Adaptor

Grahams

Altech

Not required

Grasslin

Tower TRV REV

Not required

Honeywell

Rad plan

Not required

Honeywell

VT117E

Not required

Honeywell

VT200E

Not required

Honeywell

VT15

Not required

Myson

TRV 2 Way

Not required

Myson

Petite

Not required

PTS

Boss Supreme

AD2

PTS

Boss Classic TRV

Required

SALUS

SALUS TRV

Not required

Screwfix

Unbranded TRV 

Not required

Siemens

TRV MTN51GB TRV

Not required

Trago Mills

Unbranded TRV

Not required

Travis Perkins

IFLO

Not required

Travis Perkins

IFLO Contract

Not required

AD1

AD2

AD3

34

35

Содержание Terrier i-Temp

Страница 1: ...nd in turn increase the potential for greater comfort and savings Pegler Yorkshire terrier i temp is just a part of the Terrier range of home heating products from Pegler Yorkshire www pegleryorkshire...

Страница 2: ...oes it do The terrier i temp is a programmable radiator control PRC that gives you time and temperature control of each individual radiator and is designed as an upgrade to existing thermostatic radia...

Страница 3: ...extra element of control allowing you to fine tune your heating room by room ROOM THERMOSTAT BOILER PROGRAMMER 9 00am 6 00am ROOM THERMOSTAT BOILER PROGRAMMER 9 00am 6 00am Timed Energy efficient set...

Страница 4: ...16 00 19 00 Heat low 06 00 09 00 Heat on Heat low 16 00 19 00 Heat on Heat low 6 7 With the terrier i temp you only heat rooms when you re using them Before terrier i temp After terrier i temp Before...

Страница 5: ...19 00 22 30 Heat on Heat low 19 00 22 30 Heat on Heat low 8 9 Before terrier i temp After terrier i temp...

Страница 6: ...5 30 Set point Saved energy Saved energy Diagram 2 Sitting room Set point KEY Boiler on i temp Saved energy Saved energy Saved energy 01 00 03 00 03 00 05 00 07 00 09 00 11 00 13 00 15 00 17 00 19 00...

Страница 7: ...ack within a menu A sub menu can be opened by using the OK Key OK key The OK Key is used to confirm save settings and start the teaching in function Comfort Set back key Switch between comfort and set...

Страница 8: ...Combination Function Keystroke Child proof combination lock both buttons LOC pushed briefly Keystroke Open Menu Opens the combination select hidden both buttons function pushed briefly Keys and funct...

Страница 9: ...be maintained up to a user defined date and time Operating modes The programming will define temperatures for a time range from 0 00 until 23 59 You can decide if you want to programme this time frame...

Страница 10: ...ations At least 2 programmes will be available as a preset 1 Bedroom bEd default cannot be changed 2 Sitting Room Sit cannot be changed 3 Customise Programme CUS this point allows you to customise the...

Страница 11: ...k temp and press OK Simple optional settings Child proof lock A key combination activates a key lock HOW Select MENU and together The same combination deactivates the key lock Manual temperature adjus...

Страница 12: ...ier i temp will automatically adjust itself when time settings change between British Summer Time and Greenwich Mean Time Automatic open window detection terrier i temp recognises a sudden fall in tem...

Страница 13: ...umb wheel to modify the temperature offset Press OK to confirm Temperature limitation tLi This is used in situations where you may want to limit the maximum temperature that can be set for a particula...

Страница 14: ...me terrier i temp will have taught in this remote control and will accept commands from it Advance setting options See Website for further details Remote control window sensor and USB PC programming A...

Страница 15: ...ies Never recharge standard batteries Doing so will present a risk of explosion Do not throw the batteries into a fire Do not short circuit batteries Used batteries should not be disposed of with regu...

Страница 16: ...erature offset reS Reset factory settings LEA Learning Teaching in mode tLi Temperature limitation hidden function C Temperatures are displayed with C Sun Comfort temperature Moon Set back temperature...

Страница 17: ...isplay LC display Receiver frequency 868 3 MHz Housing dimensions 63 x 70 x 99mm W x H x D Connection M30 x 1 5 Ambient temperature 5 to 55 C Max surface temperature 90 C of radiator Linear travel 4 2...

Страница 18: ...Not required Drayton RT414 Not required Drayton TRV4 Not required Drayton TRV3 AD3 Branding Branding Adaptor Grahams Altech Not required Grasslin Tower TRV REV Not required Honeywell Rad plan Not req...

Страница 19: ...ody Note you will need to open the adaptor with a screwdriver for it to fit fully onto the body 3 Use the small bolt and nut to secure the adaptor to the body 4 Place the i temp head onto the valve bo...

Страница 20: ...perature around them and regulate the flow of water through the radiator which they are fitted to They do not control the boiler They should be set at a level that gives you the room temperature you w...

Отзывы: