33
Group 2. OUTPUT
21tt
tt: Door release time from 01 to 98 in unit of 1
seconds.
2199: Output becomes normality, both on or off to
switch.
22tt
Alarm time . tt= 00 to 99 in unit of 1 seconds.
23tt
Door monitoring time.tt=00 to 99 in unit of 1 seconds.
240n
Trial error alarm, n= error times.
25tt
tt:display time from 01 to 97 in unit of 1 seconds.
2600/2601
Disable/ enable expiry date check (validity date
programmed by PC only).
*2700
Display fix duty name by ROM.
*2701
Definable duty name by PC.
*2702/04/08
2/ 4/ 8 digit duty name.
2801
Enable bell alarm mode (Trade-off with 1101).
*2901
Enable staff Nr. Display.(Trade-off with
2601,1701-1703)
Group 3. OPERATION MODES
3200
Card only mode
3300
Card + PIN mode
3301
External reader needs to press PIN too(for 3300 mode)
3400
Disable 3401/3402
3401
Enable card No.+ PIN code key only mode by keying.
(Press * + card No.+ PIN code)
3402
Enable door PIN mode.(Press 7 + PIN code)
3500/3501
Unlock/Lock the keypad
3600
Disable 3601/3602
3601
Enable duress code for card No.+PIN
3602
Enable duress code for door PIN