background image

ISSUED: 08-09-06  SHEET #: 055-9469-2  04-11-08

Visit the Peerless Web Site at www.peerlessmounts.com

4 of 9

For customer care call 1-800-729-0307 or 708-865-8870.

U

U

Y

WOOD
JOIST

CEILING

Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (

Y

) with two #14 x 2.5"

(6 mm x 65 mm) wood screws (

U

) as shown using 3/8" (10 mm) socket wrench.

Skip  to step 2

Installation To Wood Joist Finished Ceilings,

Exposed Wood Joists, or Wood Beam Ceilings

• Tighten wood screws so that ceiling plate is firmly

attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding
power.

• Never tighten in excess of 80 in • lb (9 N.M.).

• Make sure that mounting screws are anchored into the

center of the studs. The use of an "edge to edge" stud
finder is highly recommended.

WARNING

• It is the responsibility of the installer to verify that the

supporting surface will safely support the combined
load of all attached hardware and components.

WARNING

1

Содержание PSM-UNV

Страница 1: ...mounts com 1 of 9 For customer care call 1 800 729 0307 or 708 865 8870 Installation and Assembly Models PSM UNV PSM UNV S PSM UNV W Tray Style Projector Mount This product is UL Listed It must be ins...

Страница 2: ...recommended Always use an assistant or mechanical lifting equipment to safely lift and position equipment Tighten screws firmly but do not overtighten Overtightening can damage the items greatly redu...

Страница 3: ...head socket pin screw 4 510 1127 510 1127 510 1127 J M4 x 16mm serrated washer head socket pin screw 4 510 1087 510 1087 510 1087 K M4 x 25mm serrated washer head socket pin screw 4 510 1082 510 1082...

Страница 4: ...Wood Joist Finished Ceilings Exposed Wood Joists or Wood Beam Ceilings Tighten wood screws so that ceiling plate is firmly attached but do not overtighten Overtightening can damage the screws greatly...

Страница 5: ...rs Do not drill into mortar joints Concrete must meet ASTM C 90 specifications Concrete must be 2000 psi density minimum Lighter density concrete may not hold concrete anchor Make sure that the suppor...

Страница 6: ...extension column to prevent any excess movement of projector mount assembly A Skip to step 2 A B Do not overtighten Overtightening may cause permanent damage to the projector Torque to 26 35 in lb 30...

Страница 7: ...F C 4 Thread tilting mechanism of top tray into ceiling plate Y Align the notch with one of the four holes of the ceiling plate Y and secure tilting mechanism with a M5 x 10 mm socket pin screw W usi...

Страница 8: ...865 8870 Slide upper tray into the lower tray as shown Do not lift more weight than you can handle Use additional man power or mechanical lifting equipment to safely handle placement of the projector...

Страница 9: ...set screw shown below using security allen wrench R or standard 4 mm allen wrench You should be able to just slightly loosen the screw so that your adjustments can be set without having to hold the pr...