Installation to Solid Concrete or Cinder Block

Make sure that wall plate (

A

) is level, use it as a 

template to mark two mounting holes. Drill two 5/16" 
(8 mm) dia. holes to a minimum depth of 2.5" (64 mm). 
Insert anchors (

H

) in holes flush with wall as shown 

(right). Place wall plate over anchors and secure with 
two #14 x 63.5 mm screws (

G

). Level, then tighten all 

fasteners.

•  When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual 

concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount 
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM 
C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a 
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

•  Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

•  Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware 

and components.

WARNING

•  Always attach concrete expansion anchors directly 

to load-bearing concrete.

•  Never attach concrete expansion anchors to 

concrete covered with plaster, drywall, or other 
finishing material. If mounting to concrete surfaces 
covered with a finishing surface is unavoidable, 
the finishing surface must be counterbored as 
shown below. Be sure concrete anchors do not 
pull away from concrete when tightening screws. If 
plaster/drywall is thicker than 5/8" (16 mm), custom 
fasteners must be supplied by installer.

WARNING

•  Tighten screws so that wall plate is firmly attached, 

but do not overtighten. Overtightening can damage 
screws, greatly reducing their holding power.

•  Never tighten in excess of 80 in. • lb (9 N.M.).

WARNING

G

CINDER BLOCK

SOLID 
CONCRETE

A

H

1

3

2

H

Drill holes and insert anchors (

H

).

Place plate (

A

) over anchors (

H

) and secure with screws (

G

).

Tighten all fasteners.

A

H

G

concrete 
surface

CUT

A

W

A

Y

 VIEW

INCORRECT

CORRECT

wall 

plate

wall 

plate

plaster/
dry wall

plaster/
dry wall

concrete

concrete

1

Содержание SmartMount SF630

Страница 1: ... screen flat against the wall Installation and Assembly SmartMount Universal Flat Wall Mount for 10 26 25 66 cm LCD Flat Panel Screens Models SF630P SF630P S SF630 SF630 S SWV110 BK SWV110 SI Max Load Capacity 80 lb 36 3 kg UL US C ISSUED 02 05 09 SHEET 202 9309 1 I D 000001876 2 ...

Страница 2: ... aptitude has experience with basic building construction and fully understands these instructions Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Never exceed the Maximum Load Capacity See page one If mounting to wood wall studs make sure that mounting screws are anchored into the center of the studs Use of an e...

Страница 3: ...4 9012 E M4 x 20 mm phillips screw 4 504 9020 504 9020 504 9020 504 9020 504 9020 504 9020 F retaining spacer 4 590 5005 590 5005 590 5005 590 5005 590 5005 590 5005 G 14 x 63 5 mm hex head wood screw 2 5S1 015 C03 5S1 015 C03 5S1 015 C03 5S1 015 C03 5S1 015 C03 5S1 015 C03 H concrete anchor 2 590 0320 590 0320 590 0320 590 0320 590 0320 590 0320 I 4 mm allen wrench 1 560 1145 560 1145 J VESA 200 ...

Страница 4: ...s G as shown Skip to step 2 on page 6 G A 1 Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Tighten wood screws so that wall plate is firmly attached but do not overtighten Overtightening can damage the screws greatly reducing their holding power Never tighten in excess of 80 in lb 9 N M Make sure that...

Страница 5: ... minimum Lighter density concrete may not hold concrete anchor Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components WARNING Always attach concrete expansion anchors directly to load bearing concrete Never attach concrete expansion anchors to concrete covered with plaster drywall or other finishing material If mounting to ...

Страница 6: ...5 phillips screws C to hook bracket B making the screws flush with bracket as shown in figures 2 1 and 2 2 2 B C C B fig 2 1 fig 2 2 Attaching Adapter Plate to Hook Plate for Flat Panel screens using VESA 200 x 100 mm mounting patterns Attach adapter plates J to hook plate B using four M5 x 6 mm screws K and four 10 flat washers L 3 K J L B ...

Страница 7: ...r if screws bottom out and bracket is still not tightly secured damage may occur to screen or product may fail WARNING D FOR VESA 100 MOUNTING PATTERN Choose hole pattern as shown below Attach hook bracket B to back of screen using four M4 x 10 mm screws D as shown below D FOR VESA 75 MOUNTING PATTERN Choose hole pattern as shown below Attach hook bracket B to back of screen using four M4 x 10 mm ...

Страница 8: ...htening can cause damage to mount Tighten screws to 20 in lb 2 26 N M maximum torque CAUTION Do not lift more weight than you can handle Use additional man power or mechanical lifting equipment to safely handle placement of the screen Failure to lock hook bracket with screws C can cause screen to come off mount if hit accidentally WARNING DETAIL 1 fig 5 fig 5 1 A C B B A C 2009 Peerless Industries I...

Страница 9: ...Bildschirm flach an die Wand Anbringung und Zusammenbau SmartMount Universal Flachbildschirmwandhalter für LCD Flachbildschirme von 10 26 Zoll 25 66 cm Modelle SF630P SF630P S SF630 SF630 S SWV110 BK SWV110 SI AUSGEGEBEN 02 05 09 BLATT NR 202 9309 1 Max Tragfähigkeit 80 lb 36 3 kg UL US C I D 000001876 2 ...

Страница 10: ...e maximale Tragfähigkeit darf niemals überschritten werden Siehe Seite 9 Achten Sie bei der Anbringung an Holzständern darauf dass die Befestigungsschrauben jeweils in der Mitte der Holzständer verankert sind Am besten eignet sich ein Balkenfinder mit genauer Kantenanzeige Ziehen Sie immer eine zusätzliche Person heran oder verwenden Sie mechanische Hebegeräte um Geräte sicher zu heben und zu posit...

Страница 11: ...12 E M4 x 20 mm Schrauben 4 504 9020 504 9020 504 9020 504 9020 504 9020 504 9020 F Abstandhalter 4 590 5005 590 5005 590 5005 590 5005 590 5005 590 5005 G 14 x 63 5 mm Holzschrauben 2 5S1 015 C03 5S1 015 C03 5S1 015 C03 5S1 015 C03 5S1 015 C03 5S1 015 C03 H Betondübel 2 590 0320 590 0320 590 0320 590 0320 590 0320 590 0320 I 4 mm Inbusschlüssel 1 560 1145 560 1145 J VESA 200 x 100 mm adapterplatt...

Страница 12: ...t mit zwei Nr 14 x 63 5 mm Holzschrauben G Fahren Sie mit Schritt 2 auf Seite 14 fort G A 1 Bei der Anbringung muss darauf geachtet werden dass die Wand die kombinierte Last von Bildschirm und allen Befestigungsteilen und komponenten tragen kann Ziehen Sie die Schrauben fest genug an dass die Wandplatte sicher befestigt ist doch ohne sie zu überdrehen Durch Überdrehen können die Schrauben beschädi...

Страница 13: ...cht Die Betondruckfestigkeit muss mindestens 2000 psi betragen In Beton mit geringerer Druckfestigkeit kann der Betondübel u U nicht halten Vergewissern Sie sich dass die Wand das Vierfache des Gesamtgewichts von Geräten und allen daran angebrachten Befestigungsteilen und Komponenten sicher tragen kann ACHTUNG Ziehen Sie die Schrauben fest genug an dass die Wandplatte sicher befestigt ist doch ohn...

Страница 14: ... enhalterung B bis die Schrauben bündig mit der Halterung abschließen siehe Abbildung 2 1 und 2 2 2 B C C B Abbildung 2 1 Abbildung 2 2 Befestigung der Adapterplatte an Hakenhalterung und Flachbildschirm unter Verwendung der Montagemuster VESA 200 und 100 mm Bringen Sie die Adapterplatte J mit den M5 x 6 mm Schrauben K und vier Unterlegscheiben Nr 10 L an der Hakenhalterung B siehe Abbildung 3 1 a...

Страница 15: ...enhalterung B mit Hilfe von vier M4 x 10 mm Schrauben D wie unten dargestellt an der Rückseite des Bildschirms D BEI MONTAGEMUSTER VESA 75 Wählen Sie das Lochmuster siehe Abbildung weiter unten Befestigen Sie die Hakenhalterung B mit Hilfe von vier M4 x 10 mm Schrauben D wie unten dargestellt an der Rückseite des Bildschirms HINWEIS Wenn das Lochmuster sich in einer Vertiefung befindet bringen Sie ...

Страница 16: ...er Halter beschädigt werden Das maximale Drehmoment zum Festziehen der Schrauben darf 20 in lb 2 26 Nm nicht überschreiten VORSICHT Heben Sie nicht schwerer als Ihre Kräfte es zulassen Ziehen Sie eine zweite Person hinzu oder verwenden Sie mechanische Hebegeräte um die sichere Platzierung des Bildschirms zu gewährleisten Wenn die Hakenhalterung nicht mit den Schrauben C gesichert wird kann der Bil...

Отзывы: