Visit the Peerless Web Site at www.peerlessmounts.com

Secure wall arm (A) to wall plate (K) using four carriage bolts (L) and lock nuts (M).

K

L

M

K

E

1

PSTK-2955, PSTK-2955-W

Installation to Wall Plate

Use a stud finder to locate the edges of the stud. Use of an edge-to-edge stud finder is highly recommended.
Based on its edges, draw a vertical line down the stud's center. Place wall plate (K) on wall as a template. Mark
the center of the four mounting holes. Drill four 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Secure wall plate
(K) to wood stud using four #14 x 2-1/2" wood screws (E) as shown. Skip to Step 3.

• Installer must verify that the supporting surface will safely support the combined load of the equipment and all

attached hardware and components.

• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the

screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).

• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is

highly recommended.

• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs.

Installers are responsible to provide hardware for other types of mounting situations.

WARNING

6 of 9

ISSUED: 03-26-09  SHEET #: 055-9259-1

Installation to Wood Stud Walls

A

Содержание PSTA-2955

Страница 1: ...eerless Web Site at www peerlessmounts com Max Load Capacity 35 lb 15 8 kg Installation and Assembly Universal Projector Wall Arm Models ISSUED 03 26 09 SHEET 055 9259 1 PSTA 2955 PSTA 2955 W PSTK 2955 PSTK 2955 W ...

Страница 2: ... of this product outdoors could lead to product failure and personal injury This product was designed and intended to be mounted to the following supporting surfaces checked below with the hardware included in this product as specified in the installation sheet To mount this product to an alternative supporting surface contact Peerless customer care at 1 800 865 2112 This product was designed to b...

Страница 3: ...320 590 0320 H 1 4 20 phillips screw 2 520 1054 520 2069 520 1054 520 2069 I 1 4 20 flat washer 2 540 1078 540 2078 540 1078 540 2078 J PRG UNV 1 PRG UNV PRG UNV W PRG UNV PRG UNV W K wall plate 1 055 1923 055 2923 L 5 16 18 x 1 2 carriage bolt 4 520 9207 520 2047 M 5 16 18 serrated flanged lock nut 4 530 1016 530 2016 Parts List A B Before you start check the parts list to insure all of the parts...

Страница 4: ...ill safely support the combined load of the equipment and all attached hardware and components Tighten wood screws so that wall plate is firmly attached but do not overtighten Overtightening can damage the screws greatly reducing their holding power Never tighten in excess of 80 in lb 9 N M Make sure that mounting screws are anchored into the center of the stud The use of an edge to edge stud find...

Страница 5: ...n installing Peerless wall mounts on cinder block verify that you have a minimum of 1 3 8 of actual con crete surface in the hole to be used for the concrete anchors Do not drill into mortar joints Be sure to mount in a solid part of the block generally 1 minimum from the side of the block Cinder block must meet ASTM C 90 specifications It is suggested that a standard electric drill on slow settin...

Страница 6: ...hown Skip to Step 3 Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Tighten wood screws so that wall plate is firmly attached but do not overtighten Overtightening can damage the screws greatly reducing their holding power Never tighten in excess of 80 in lb 9 N M Make sure that mounting screws are an...

Страница 7: ...alling Peerless wall mounts on cinder block verify that you have a minimum of 1 3 8 of actual con crete surface in the hole to be used for the concrete anchors Do not drill into mortar joints Be sure to mount in a solid part of the block generally 1 minimum from the side of the block Cinder block must meet ASTM C 90 specifications It is suggested that a standard electric drill on slow setting is u...

Страница 8: ...nto place using two M5 x 10 mm screws D B A Assembly of Adjustment Tube ISSUED 03 26 09 SHEET 055 9259 1 Installing PRG Projector Mount PSTA 2955 PSTA 2955 W Installing PRG projector mount to wall arm assembly Attach PRG projector mount J to adjustment tube B using two 1 4 20 phillips screws H and two flat washers I as shown in Figure 4 1 fig 4 1 D ARROW INDICATES FRONT OF MOUNT H I J ...

Страница 9: ...in projector mount and wall arm assembly as shown below Insert Tube Cap F into end of adjustment tube B 2009 Peerless Industries Inc All rights reserved All other brand and product names are trademarks or registered trademarks of their respective owners B F PROJECTOR CABLES Note Cables must be removed from projector before routing through wall arm Note Follow projector mount PRG instructions to in...

Отзывы: