8
2013-08-27 #:125-9465-5 2014-04-21
2b-1
2b-2
5/16"
(8mm)
2.5"
(64mm)
5/16"
(8mm)
Level wallplate. Mark mounting holes.
ENG
Do not drill into mortar joints.
ENG
A
Drill mounting holes into supporting surface
(2.5" (64mm) minimum depth required).
ENG
2b
ENG • When installing Peerless wall mounts on a concrete wall, the wall must be at least 8" thick with a minimum
compressive strength of 2000 psi.
• When installing Peerless wall mounts on a cinder block wall, the cinder blocks must meet ASTM C-90
specifications and have a minimum nominal width of 8". Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" (25 mm) minimum from the side of the block. It is suggested that a standard electric
drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole
when entering a void or cavity.
• Never attach expansion anchors to concrete or cinder block covered with plaster, drywall or other finishing
material.
WARNING
Содержание DS-VWM770
Страница 1: ...1 2013 08 27 125 9465 5 2014 04 21 DS VWM770 ENG 46 70 1168 1778 cm 125 lb 56 kg MAX...
Страница 10: ...10 2013 08 27 125 9465 5 2014 04 21 3 A...
Страница 16: ...16 2013 08 27 125 9465 5 2014 04 21 9 2 9 3 9 1 9 Display adjustment ENG...
Страница 19: ...19 2013 08 27 125 9465 5 2014 04 21 This page intentionally left blank ENG...