![Peek Traffic 625X Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/peek-traffic/625x/625x_installation-manual_1520187003.webp)
3
Quick Setup
1.
Verify the input voltage by looking at the label on the back
of the detector (located just under the connector.)
2.
Terminate the wiring harness to the proper connector on
the terminal strip for each of the desired functions (power,
desired outputs, loop, etc.)
3.
Connect the harness to the detector.
4.
Verify power is reaching the detector. (The Presence LED
should come on and flash for two seconds, then go out.)
5.
Set sensitivity switch (SENS) to Medium (M).
6.
Adjust the frequency (FREQ) to Low (L) for a single loop.
For multiple loop applications, set each detector to a differ-
ent frequency setting.
7.
Press and hold the RESET button for three seconds, until
the Presence LED flashes. The detector is ready to oper-
ate.
Upon power-up, Presence LED will flash
for 2 seconds, then go out.
Sensitivity: First set to Medium, then
adjust if necessary.
Frequency: Set to Low or Medium for
single loop installations.
To Reset Detector: Press and hold for 3
seconds, or until Presence LED blinks.