![Peek Traffic 625X Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/peek-traffic/625x/625x_installation-manual_1520187010.webp)
10
Output Configuration Options
Presence
means the relay will be energized the entire
time a metal mass is within the field generated by the
loop. The 625X has the ability to provide two presence
outputs. Relay 2 can be set for presence or pulse.
Relay 1 is always presence (pins 5 & 6, yellow and
blue wires), however Relay 2 on the 625X can be
assigned to one of several output configurations.
Relay 2 (pins 3 & 9, Orange and Red wires) can be set
for presence using the switches on the back panel. Set
switch 3 to OFF and switch 2 to ON
Pulse on Entry
means that the relay 2 will be ener-
gized as soon as a metal mass enters the field gener-
ated by the loop. On the back panel, set switch 3 to
OFF and switch 2 to OFF. This pulse will last 125mS.
Pulse on Exit
means that relay 2 will be energized
when a metal mass has left the loop. Set switch 3 to
ON and switch 2 to OFF. The pulse will last 125mS.
Loop fault output
means the relay will be energized if
there is a current fault (open loop, shorted loop or
greater than a 25% inductance
change.) Set switch 3 to ON
and switch 2 to ON.
3
2
1
ON
Switches 2 & 3 control which
output function of Relay 2 is used.
Switch 1 ON doubles the sensitivity
settings on the front panel