Peecker Sound JADSP1250 Скачать руководство пользователя страница 9

 

 

Via Monti Urali, 29 – 42122 Reggio Emilia (Italy) • Telephone: +39 0522 557735 • [email protected] 

 

Charge Safety Control: 

The charge is constantly measured and displayed on the software panel if its value 
exceeds a factory set range.

 

 

DC Protection: 

The presence of output direct current is monitored: in that case the output stage of the 
amplifier and the switching power supply would be inhibited. This allows to protect the 
cone loudspeakers from direct current. It is enough to turn off and restart the amplifier to 
reactivate it. 
 

Protection from Mains Power: 

Mains input is supplied with a limiter for inrush current and fuse (outside) fluxes. System is 
automatically protected and restarted in case of voltage drop. It is supplied with a system 
of automatic adaptation to all the values of mains tension included between 
115 and 230 V. 

 

 
Noise Generator 

 

It is supplied with two buttons, one to activate the noise generator (button 4. - Figure 2), 
the other to select white and pink noise (

5. Pink noise / White noise

 – Figure 2). The green 

led (3. Active - Figure 2) indicates that the noise generator is on.  
By a remote control supplied it is possible to activate the noise muting (that is to stop the 
generated noise) from a remote place. The noise muting is indicated by the red led (

2. 

Mute – Figure 2).

 Activating the noise muting causes the switching off of the cooling fan for 

a few seconds. It allows to perform measures of noise stopping without the disturbing 
noise of the fan. 
 

 

      

 

Figure 4: JA-BT optional device 

 

 

With the JA-BT optional device (a battery power kit with an inverter to use the devices 
without mains – Figure 4), the “JA-BT FAN CONTROL” connector allows to connect JA-BT 
to JADSP1250 causing the switching off of  JA-BT fan while the noise muting is activated.  
“LEVEL” potentiometer allows to dose the amplitude of the noise sent to the amplifier. With 
the switch OFF (13. User DSP – Figure 2), that is DSP control off, and the switch 5. set on 
“pink noise”, turning completely the potentiometer clockwise (highest level) corresponds to 
the maximum acoustic emission of the dodecahedron, without distortions or any thermal or 
power protections. 

 
 
 
 

Содержание JADSP1250

Страница 1: ...IDGE MIN 8 C D MIN 4 PIN1 2 PIN1 2 SPEAKER IMPEDANCE C D A B OUTPUTS BRIDGE BRIDGE OUTPUTS B A BRIDGE MIN 8 A B MIN 4 PIN1 2 PIN1 2 SPEAKER IMPEDANCE B A 2 1 3 GND BRIDGE STEREO INPUTS AC 230V 10 50Hz...

Страница 2: ...measurements of building and architectural acoustics acoustic insulation acoustic absorbtion reverberation time impulse responses measurements acoustic parameters of halls passive requirements of the...

Страница 3: ...12 Connect only according to instructions 13 Do not connect an input signal exceeding what indicated in the manual 14 Do not connect the output of the amplifier to the input of another channel 15 Do...

Страница 4: ...fications of this device in order not to damage the amplifier and or the charge Radio Interferences A sample of this product was tested and homologated according to the limits of the Electromagnetic C...

Страница 5: ...mponents Check carefully that there is room enough on the front side of the amplifier to allow air to get in and to the hot air to get out Do not put on objects that could obstruct the ventilation ope...

Страница 6: ...ph DSP Remote Control 10 Audio Link XLR male connector for the link of the signal present in 11 Audio input to another device 11 Audio Input XLR female connector for the input to the DSP max 10 dBu ac...

Страница 7: ...Via Monti Urali 29 42122 Reggio Emilia Italy Telephone 39 0522 557735 info peeckersound com Figure 2 JADSP1250 front panel and numbered scheme...

Страница 8: ...rks supplementarly to the peak limiter and it allows not to exceed the thermal thresholds of power tight of transducers Exceeding this threshold would cause a proportionate decrease of the gain that o...

Страница 9: ...ite and pink noise 5 Pink noise White noise Figure 2 The green led 3 Active Figure 2 indicates that the noise generator is on By a remote control supplied it is possible to activate the noise muting t...

Страница 10: ...The red led indicates one of the following possible status saturation of the DSP input AD converter intervention of the DSP peak limiter intervention of the RMS limiter on the output of the amplifier...

Страница 11: ...heared refers to the core presets See paragraph DSP Remote Control for more details For further exlanations please refer to Figure 5 Amplifier The two channel amplifier is made with switching tchnolo...

Страница 12: ...to leave the adapter cable connected to the dodecahedron for the following uses of JA12 and to consider it an integral part of it Therefore the following output connections are possible only JA12 dod...

Страница 13: ...icated to the user s control as explained above To do it it is necessary to install the PS NET Network Controller software available in the enclosed CD see the following paragraph The two EtherCon con...

Страница 14: ...less of the factory preset selected by the other switch It allows to get signal muting gain equalizations 8 bands and 2 shelvings LP and HP frequency cuts delay and two unrelated level attenuations on...

Страница 15: ...nitially limiters applied persistent over temperature causes shutdown Brownout Automatic protection recovery Mains Inrush current limiting DC fault Shut down power cycle to recover Indicators and swit...