2
Transport and Storage Environmental Conditions (not to exceed 15 days)
Ambient temperature range of -40°F (-40°C) to +158°F (+70°C)
Relative humidity range of 10% to 100%, including condensation
Atmospheric pressure range of 50KPa to 106KPa
The Pedigo Warming Cabinet has been
thoroughly tested, checked for calibration,
and inspected to insure only the highest
quality. When you receive your unit, check
for any possible shipping damage and
report it at once to the delivering carrier.
The cabinet, complete with unattached items and
accessories, may be delivered in one or more packages. Save all
the information and instructions packed inside the cabinet.
Complete and return the warranty card to the factory as
soon as possible to assure prompt service in the event of a
warranty parts and labor claim.
All claims for warranty must include
the full model number and serial number of the cabinet.
After unpacking the unit, allow it to remain under stable
atmospheric conditions for several hours before connecting to
the power source. Extreme changes in temperatures and/or
humidity during storage and/or transportation could have
allowed condensation to form in the unit.
NOTE
:
Pay particular attention throughout this manual to
the warning and caution symbol which
means: Attention, Consult Operation
Manual before proceeding.
E L E C T R I C A L I N F O R M AT I O N
The power specifications are located on the unit
identification nameplate. This nameplete is permanently
attached to the unit and must be located to determine and
verify power requirements.
POWER REQUIREMENTS
120 V.A.C. — 60 Hz, 1 ph
2000 Watts, 16.0 Amps
The double compartment warming cabinet is constructed with
22 gauge stainless steel exterior casing and doors, with handles
and hinges designed to withstand heavy usage. The cabinet is
heated by means of the Halo Heat system incorporating low
watt density cable mounted around each compartment. This
system provides evenly distributed heat without the need of a
heat-circulating fan. Each compartment is controlled by an
adjustable, electronic thermostat, which includes a heat
indicator L.E.D., temperature set button, temperature increase
and decrease button, and digital display to monitor
compartment temperature. The thermostats have a
temperature range of 90°F (32°C) minimum to 200°F (93°C)
maximum. Each chamber is equipped with one (1) white, epoxy-
coated blanket support assembly, with shelf. The cabinet is
furnished with one (1) set of 5" (127mm) heavy-duty casters —
two rigid and two swivel with brake.
P R E PA R AT I O N
Before operating the cabinet, clean both the interior and exterior
of the unit with a damp cloth and mild soap solution. Wipe with
an appropriate disinfectant. Clean and install the cabinet shelf
assembly. Do not install or operate the blanket warmer in close
proximity of flammable anesthetics.
B L A N K E T WA R M I N G C A B I N E T S
T R A N S P O R T a n d S T O R A G E
G E N E R A L I N F O R M AT I O N
N E M A 5 - 2 0 P
20A - 125V Plug
Hospital Grade
At no time should the inside or outside of
the cabinet be washed down by flooding with
water or liquid solution.
N E V E R S T E A M
C L E A N .
S e v e r e d a m a g e o r e l e c t r i c a l
hazard could result.
Danger!
Explosion risk if used in
the presence of
flammable anesthetics.
Grounding reliability can only be achieved when equipment is connected to
an equivalent receptacle marked "Hospital Grade."
Protective Earth
Ground Symbol
Medical Equipment classified by Underwriters
Laboratories with Respect to Electrical Shock, Fire
and Mechanical Hazards only, in Accordance with
UL 544 and CAN/CSA C22.2 No. 601.1.
U N P A C K I N G A N D S E T - U P
IP50
MADE IN USA
MODEL
SERIAL#
WATTS
AMPS
VOLTS
1 PH
Hz
LISTED
MEDICAL EQUIPMENT
C
LISTED
US
MEDICAL EQUIPMENT
1P50
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON UNIT NAMEPLATE.
Hazardous
Voltage Present
Pedigo P-2040-S Blanket Warming Cabinet Operation and Care Manual