14
Inputs A and B or outputs 1-6 should be selected on the top of the
screen. While on the top of the screen push the data wheel and an
arrow appears. Rotate the wheel to select which input or output
you wish to adjust. Push the data wheel to accept. Normally the
output delays are used to align the phase response of the drivers in
a system while the input delays are useful for adding delay to the
entire system(s).
IN/OUT:
Toggles to engage or bypass the delay
NORM/REvERSE:
Toggles to invert the polarity from the present state. It may become necessary to flip the polarity many times
while adjusting the delay time or adjusting the cut-off rate of the filters. It is conveniently located on this page
for that purpose.
DELAY:
Adds delay to the selected input or output. The delay is displayed in milliseconds, feet and meters and
automatically calculates each as the data wheel is rotated. The range of each delay is 340 ms, 379.09 feet and
115.59 meters. The input delay amount will be added to the output delay amount for a possible 680 ms, 758.18
feet and 231.18 meters should a very long delay be necessary. One example would be for use with delay towers.
Delay Screen