20

50

100

200

500

1k

2k

5k

10k

20k

Frequency (Hz)

60

70

80

90

100

110

dB

SPL

(re

20

Pa)

Amplitude Response (1m Equivalent On-Axis)

No LF Crossover

With Crossover

VR112 Only

Figure 1

20

50

100

200

500

1k

2k

5k

10k

20k

Frequency (Hz)

1

10

100

Q & Directivity Index

Q

Figure 4

20

10

Di

0

20

50

100

200

500

1k

2k

5k

10k

20k

Frequency (Hz)

5

10

20

30

40

60

80

100

140

180

300

360

Beamwidth

(Degrees)

Beamwidth

Vertical

Horizontal

Figure 3

20

50

100

200

500

1k

2k

5k

10k

20k

Frequency (Hz)

1

2

3

5

10

20

30

50

100

Impedance

High Frequency

Mid Bass

Z

( )

Figure 2

SPECIFICATIONS 

 Versarray

 112 Mk2

FG# 00584980  White (as of 6/21/10)
Spare coupling plates
(Or for use with the Pull-Back Bar, 2 per hang 
needed)
Versarray 112 Mk 2 #32000828
Optional Hardware for convenience:
Quick Release Positive Lock Pins
Versarray 100 series quick release positive 
lock pins, 1/4" diameter pin
FG# 00594020 (set of four)

Note:  Most Versarray 100 series products come 
with 1/4" X 20 Grade 5 bolts, if you wish to use 
the quick release positive lock pins, then you 
will need enough for each location, normally 12 
per cabinet.  The Halo and Pull Back bar come 
with the pins included.

Содержание Versarray 112 Mk2

Страница 1: ...one module at 1 meter a line array of 6 units has much higher output at distance due to line source effect where SPL falls off at 3 dB per distance doubling rather than 6 dB Nominal Radiation Angle measured at 6 dB point of polar response 90 degrees Horizontal by 15 degrees Vertical One module only straight line array of more than 1 module narrows vertical dispersion accordingly Transducer Complem...

Страница 2: ...mposite material sandwich ribbon New ribbon tweeters have 50 more power handling and 2 dB more sensitivity than the Mk1 90 H by 15 V degree coverage pattern per one cabinet Easy aiming angle adjustment rigging system Angle adjustable in 2 1 2 degree increments from 0 to 15 degrees total angle between adjacent cabinets Sound Guard tweeter protection Inputs are two Neutrik Speakon 4 pin jacks in par...

Страница 3: ...t mating hardware All associated rigging is the responsibility of others NOTE Before you fly the array be sure to inspect the rigging and flying hardware to insure that it is mechanically sound and has not been damaged there should be no significant distortion of the shape of the coupling brackets cabinet brackets or fly bar and the hardware should be checked for tightness IF ANY OF THE BRACKETS O...

Страница 4: ...lifier use Peavey s proprietary protection circuitry Sound Guard provides long and medium term driver overload protection for the tweeter without impairing musical transients or dynamics The adjustable rigging system provides for a classic straight line array configuration or a number of different angling options providing easy aiming of the system Angles between the array modules is adjustable fr...

Страница 5: ...ubs subtract 6 dB for each time they are doubled SPECIAL NOTE To match this PEQ setting with a 1 3 octave band EQ use the following To equate to a PEQ setting of 3 dB 1 8k bw 0 58 use 1 3 octave band 2 kHz set to 1 5 dB AND 1 3 octave band 1 6 kHz also set to 1 5 dB To equate to a PEQ setting of 3 5 dB 1 8k bw 0 58 use 1 3 octave band 2 kHz set to 2 dB AND 1 3 octave band 1 6 kHz set to 1 5 dB To ...

Страница 6: ...needs to be adjusted down to 90 Hz and some EQ pull back may be required around 200 250 Hz NOTE Check with Peavey Transducer Engineering for the latest info on more recent settings and any changes to the EQ Paralleling Versarray 112 Mk2 drivers on one amp channel The ribbon tweeters impedance can be configured to be in either a 16 ohm load factory default or a 4 ohm load In 16 ohm impedance config...

Страница 7: ...maged there should be no significant distortion of the shape of the coupling brackets cabinet brackets or fly bar and the hardware should be checked for tightness IF ANY OF THE BRACKETS OR THE FLY BAR HAS BEEN DAMAGED OR DISTORTED DO NOT USE AND DO NOT FLY THE ARRAY UNTIL THEY CAN BE REPLACED OR REPAIRED DO NOT USE THE COUPLING BRACKETS AS HANDLES TO TRANSPORT THE CABINETS Use only the correct mat...

Страница 8: ...quency Hz 1 2 3 5 10 20 30 50 100 Impedance High Frequency Mid Bass Z Figure 2 SPECIFICATIONS Versarray 112 Mk2 FG 00584980 White as of 6 21 10 Spare coupling plates Or for use with the Pull Back Bar 2 per hang needed Versarray 112 Mk 2 32000828 Optional Hardware for convenience Quick Release Positive Lock Pins Versarray 100 series quick release positive lock pins 1 4 diameter pin FG 00594020 set ...

Страница 9: ... 120 dB SPL re 20 Pa Harmonic Distortion 10W Power Figure 6 3rd Harmonic 2nd Harmonic 20 50 100 200 500 1k 2k 5k 10k 20k Frequency Hz 40 50 60 70 80 90 100 110 dB SPL re 20 Pa Harmonic Distortion 1W Power Figure 5 3rd Harmonic 2nd Harmonic SPECIFICATIONS Versarray 112 Mk2 ...

Страница 10: ...SPECIFICATIONS Versarray 112 Mk2 Input Cup ...

Страница 11: ...SPECIFICATIONS Versarray 112 Mk2 Dimensions 11 625 13 875 24 918 WITHOUT BRACKET 25 184 WITH BRACKET 11 625 25 184 WITH BRACKET 24 918 WITHOUT BRACKET ...

Страница 12: ...SPECIFICATIONS Versarray 112 Mk2 0 0 2 Pin 2 5 5 ...

Страница 13: ...SPECIFICATIONS Versarray 112 Mk2 15 10 7 5 12 5 ...

Страница 14: ...SPECIFICATIONS Versarray 112 Mk2 Detail A Scale 1 1 Cabinet Fly Bar Diagram ...

Страница 15: ...SPECIFICATIONS Versarray 112 Mk2 Coupling Bracket Diagram Cabinet Bracket Diagram ...

Страница 16: ...ed only to equipment manufactured after 13 August 2005 www peavey com Warranty registration and information for U S customers available online at www peavey com warranty or use the QR tag below Features and specifications subject to change without notice Peavey Electronics Corporation 5022 Hartley Peavey Drive Meridian MS 39305 601 483 5365 FAX 601 486 1278 ...