IMPORTANT SAFETY INSTRUCTIONS

  WARNING:

 When using electrical products, basic cautions should always be followed, including the following:

1. 

Read these instructions. 

2. 

Keep these instructions.

3. 

Heed all warnings.

4. 

Follow all instructions.

5. 

Do not use this apparatus near water. 

6. 

Clean only with a dry cloth.

7. 

Do not block any of the ventilation openings. Install in accordance with manufacturer’s instructions. 

8. 

Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) 
that produce heat.

9. 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one 
wider than the other. A grounding type plug has two blades and a third grounding plug. The wide blade or third prong is 
provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the 
obsolete outlet. 

10. 

Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point 
they exit from the apparatus.

11. 

Note for UK only: If the colors of the wires in the mains lead of this unit do not correspond with the terminals in your 
plug‚ proceed as follows:

 

a) The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E‚ the earth 
symbol‚ colored green or colored green and yellow.

 

b) The wire that is colored blue must be connected to the terminal that is marked with the letter N or the color black.

 

c) The wire that is colored brown must be connected to the terminal that is marked with the letter L or the color red.

12. 

Only use attachments/accessories provided by the manufacturer.

13. 

Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a 
cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

14. 

Unplug this apparatus during lightning storms or when unused for long periods of time.

15. 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any 
way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, 
the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

16. 

Never break off the ground pin. Write for our free booklet “Shock Hazard and Grounding.” Connect only to a power 
supply of the type marked on the unit adjacent to the power supply cord.

17. 

If this product is to be mounted in an equipment rack, rear support should be provided.

18. 

Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in suscep-
tibility to noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise 
for a sufficient time. The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the 
following permissible noise level exposures:

 

 

Duration Per Day In Hours 

Sound Level dBA, Slow Response

 

 

90

 

 

92

 

 

95

 

 

97

 

 

100

 

 

1

2

 

102

 

 

105

 

 

1

2

 

110

 

 

1

4

 or less 

115

According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss. Ear plugs or protectors to 
the ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss, if 
exposure is in excess of the limits as set forth above. To ensure against potentially dangerous exposure to high sound pressure levels, it is 
recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system be 
protected by hearing protectors while this unit is in operation.

SAVE THESE INSTRUCTIONS!

Содержание Q 1311

Страница 1: ...Q Series Operation Manual For more information on other great Peavey products go to your local Peavey dealer or online at www peavey com ...

Страница 2: ...mbole est utilisé dans ce manuel pour indiquer à l utilisateur la présence d une tension dangereuse pouvant être d amplitude suffisante pour constituer un risque de choc électrique Ce symbole est utilisé dans ce manuel pour indiquer à l utilisateur qu il ou qu elle trouvera d importantes instructions concernant l utilisation et l entretien de l appareil dans le paragraphe signalé ATTENTION Risques...

Страница 3: ...d with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 14 Unplug this apparatus during lightning storms or when unused for long periods of time 15 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been s...

Страница 4: ...accuracy Whether on stage in the studio or simply tweaking your home hi fi system the Q Series has an EQ for you FEATURES Q2151 Dual channel 15 bands per channel 2 3 octave filter sets 25 Hz to 16 kHz effective equalization range Constant Q filters Switchable 12 dB 6 dB of boost cut in each frequency band Output level LEDs 12 to 12 dB 24 dB per octave 40 Hz low cut filter with status LED XLR and 1...

Страница 5: ...ot be attainable regardless of the equalizer used all system components must be of high quality and designed for the application No amount of equalization will correct poor acoustics poor microphone speaker arrangement or the response curve of a poor loudspeaker FEATURES AND CONTROLS 1 OUTPUT LEVEL LED METER This LED array indicates output level from 12 dB to 12 dB 2 GAIN This calibrated detented ...

Страница 6: ...ent It is provided for your safety If the outlet used does not have a ground pin a suitable grounding adapter should be used and the third wire should be grounded properly To prevent the risk of shock or fire hazard always make sure that the equalizer and all associated equipment are properly grounded NOTE FOR UK USERS ONLY If the colors of the wires in the mains lead of this unit do not correspon...

Страница 7: ...anced input when used with TRS connectors and two conductor shielded cables When used with mono 1 4 TS phone plugs the input is unbalanced 11 XLR INPUT These three pin female connectors provide balanced input when used with male XLR connectors 12 12 dB 6 dB SWITCH This switch changes the boost and cut range in each frequency band from 12 dB default to 6 dB for improved precision ...

Страница 8: ...edance 200 Ohms Maximum Input Level 20 dBu Maximum Output Level 20 dBu Unbalanced 26 dBu Balanced Nominal Input Output Levels 0 dBu Input Headroom 20 dB Output Headroom 20 dB Unbalanced 26 dB Balanced Maximum Gain Boost Cut 12 dB Low Cut Filter 40 Hz 24 dB oct Power consumption Domestic 120 VAC 60 Hz 12 Watts Export 230 VAC 50 60 Hz 12 Watts Dimensions 1 73 44 mm H x 19 483 mm W x 7 375 187 mm D W...

Страница 9: ...9 Q Series BLOCK DIAGRAM ...

Страница 10: ...ill pay the return shipping charges How To Get Warranty Service 1 Take the defective item and your sales receipt or other proof of date of purchase to your Authorized Peavey Dealer or Authorized Peavey Service Center OR 2 Ship the defective item prepaid to Peavey Electronics Corporation International Service Center 412 Highway 11 80 East Meridian MS 39301 or Peavey Canada Ltd 95 Shields Court Mark...

Страница 11: ...Features and specifications subject to change without notice Peavey Electronics Corporation 711 A Street Meridian MS 39301 601 483 5365 FAX 601 486 1278 www peavey com 2002 Printed in the U S A 8 02 ...