Peavey PVXp 15 DSP Скачать руководство пользователя страница 14

Group D

A set of four M8 inserts on the right side, designed to be used with the Peavey Versamount 70+ mounting brack-

et.

Group E

A set of four M8 inserts on the bottom, designed to be used with the Peavey Versamount 70+ mounting bracket.

For Group A and B, always use both inserts as a pair; NEVER use just one insert to fly a cabinet!

For Group C, D and E, Always use all four inserts of a given group as a set; NEVER use just one insert to fly a 

cabinet! The four insert groupings are meant to have all four inserts used at once within a group.

Group E should only be used with the Versamount 70+ oriented beneath the cabinet, and at an angle less than 30 

degrees from vertical.

SPECIFICATIONS FOR INSERT MATING HARDWARE

Group A and Group B should use an M10 forged steel shoulder-type lifting eyebolt, which meets the require-

ments of DIN 580 or ASTM A489. They should only be used in pairs, and in conjunction with the rear most pair 

of M8 inserts on the same surface as a pull-back/aiming adjustment, using M8 eyebolts of a similar specification. 

The length of the threaded shank on the eyebolts should not exceed 3/4” (approx. 20 mm), so that it does not 

bottom-out in the insert. Thread pitch: 1.5 mm per thread.

Group C and D should use an M8, grade 8.8 or better, 1.25 mm per thread, metric bolt, that does not penetrate 

the cabinet beyond the cabinet surface more than 3/4 ” (approx. 20 mm). When using a Peavey Versamount 70+ 

mounting bracket and lock washer, the length of the bolt should not exceed 1.125” (approx. 30 mm).

Group E should use an M8, grade 8.8 or better, 1.25 mm per thread, metric bolt, that does not penetrate the 

cabinet beyond the cabinet surface more than 0.472” (12 mm). When using a Peavey Versamount 70+ mounting 

bracket and lock washer, the length of the bolt should not exceed 3/4” (approx. 20 mm).

WARNING! (note to structural engineer)

The thread insertion depth past the surface of the cabinet of the end of the mounting bolt should not be more 

than 0.787” (20 mm) for insert groups A, B, C and D, and not more than 0.472” (12 mm) for Group E.

If these thread insertion depths are exceeded, then the inserts may be damaged or unseated from the cabinet, 

severely compromising the mounting integrity of the cabinet!

For maximum mounting strength, safety and reliability, the bolt threads should engage at least 10 mm of depth 

for Group A and B, and at least 8 mm of depth for groups C, D and E.

The PVXp™ 15 DSP mounting insert groups C, D and E are designed to be used with the Peavey Versamount 70 

Plus mounting bracket (00454470 black, 00454460 white), as well as the Impulse® 15” array bracket (00475780 

black, 00479360 white). It can also be used with the Peavey Wall-Mount Speaker Stand (00922940 black, 

00487390 white), which will fit into the built-in stand mount cup on the bottom of the cabinet.

Содержание PVXp 15 DSP

Страница 1: ...www peavey com PVXp 15 DSP Powered Speaker System Operating Manual...

Страница 2: ...the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This...

Страница 3: ...r professional grade components Fan cooled for maximum reliability Patented Quadratic Throat Waveguide technology 100 by 50 degree coverage Asymmetrical horn aims the sound down 10 degrees at the audi...

Страница 4: ...lay The PVXp 15 DSP speaker system power amplifiers providing the bi amplification are low distortion ultra reli able fan cooled units providing a total of 830 peak available dynamic power for the sys...

Страница 5: ...ips Then once the fresh fuse has been put in place re insert the fuse tray into the IEC connector assembly and make sure it is fully seated and flush with the outside of the IEC connector assembly It...

Страница 6: ...connecting a cd or MP3 players Gnd LIFT switch 5 Allows the shield to be disconnected from the chassis ground to alleviate hum from ground loops Level 6 Controls the gain or output level of the input...

Страница 7: ...o the system is likely if this occurs DO NOT connect the inputs of the PVXp 15 DSP to the output of a power amplifier The inputs are meant to be driven from a line level strength signal DO NOT remove...

Страница 8: ...system from being blown over Connecting a Signal to the PVXp 15 DSP There are a variety of ways to input a signal to the PVXp 15 DSP The input 4 provides either a balanced mic or line level input allo...

Страница 9: ...o reach full desired output With this approach it is necessary to verify the mixer output is not clipping Disconnecting AC Power to the PVXp 15 DSP We recommend that the Power switch 1 be used to turn...

Страница 10: ...s on the screen Turning the adjust ment clockwise makes it brighter while turning it counter clockwise makes the characters dimmer Contr Contrast The second adjustment is the contrast The contrast adj...

Страница 11: ...ed or broken off as this is a potential safety hazard Distorted or Fuzzy Sound First ensure the mixer signal source is not clipping or being overdriven Make sure the Level 6 control on the PVXp 15 DSP...

Страница 12: ...f 1M and driven to full output capacity The system shall utilize a Peavey Pro 15 15 heavy duty woofer and a Peavey RX 14 1 4 titanium diaphragm dynamic compression driver The nominal radiation pattern...

Страница 13: ...e manual update notices This system should be suspended with certi fied rigging hardware by an authorized rigging professional and in compliance with local state or provincial and federal or national...

Страница 14: ...that does not penetrate the cabinet beyond the cabinet surface more than 3 4 approx 20 mm When using a Peavey Versamount 70 mounting bracket and lock washer the length of the bolt should not exceed 1...

Страница 15: ...ey filter Input Connections One combo female XLR and 1 4 phone jack providing balanced line level operation from the 1 4 jack section and high output dynamic microphone operation from the XLR section...

Страница 16: ...al Line 2 2 k ohms balanced 1 4 10 k ohms unbalanced 1 4 Mic 2 2 k ohms balanced XLR No phantom power available Input Sensitivity for Full Output Level full CW 0 48V RMS in the Line position 0 01V RMS...

Страница 17: ...8 205 mm 3 35 85 mm 6 153 mm 5 127 mm 2 76 70 mm 2 76 70 mm 10 24 260 mm 17 430 mm 9 45 240 mm 18 9 480 mm 5 127 mm 28 710 mm 14 357 mm 9 45 240 mm 5 127mm 6 26 159 mm 2 76 70 mm 2 76 70 mm 8 205 mm 3...

Страница 18: ...d only to equipment manufactured after 13 August 2005 www peavey com Warranty registration and information for U S customers available online at www peavey com warranty or use the QR tag below Feature...

Отзывы: