Peavey PV 1 Скачать руководство пользователя страница 3

INPUT GAIN (dB)

 

These controls are used to adjust the input gain of each channel. They determine how “loud” each channel of the power amplifier 

will sound for a given input signal level. Maximum input gain is achieved at the fully clockwise setting (+32 dB, 40 X), and this 

setting yields maximum mixer/system headroom. A setting of less than fully clockwise will yield lower system noise at the 

expense of mixer/system headroom. Turning the control fully counterclockwise is the “off” setting (-∞). It is always a good idea to 

power up any new installation at this setting to protect the system loudspeakers.

POWER LEDS (PWR)

 

These indicators illuminate when the AC mains power is being supplied to the amp and both channels are operational. If either 

channel experiences fault conditions, exceeds safe operating temperature limits, or if the mains circuit breaker trips; both channel 

power LEDs will be dark, indicating “shutdown”. If the BRIDGE mode is selected, the PWR indicator on channel B will remain 

dark as a positive indication of this mode selection.

SIGNAL ACTIVITY LEDS (SIG)

These indicators illuminate when the associated channel output signal level exceeds 1 V RMS.

DDT™ ACTIVE LEDS 

These indicators illuminate when DDT compression is taking place in the associated channel. If the rear panel DDT switch is 

depressed, then DDT is defeated and these LEDs indicate clipping is occurring in the corresponding channel. The Peavey DDT 

compression system will be covered in greater detail later in this manual.

Thermal Protect LED

This indicator illuminates when the thermal sensor on either heatsink reaches approximately 90 degrees C, at which point, the 

amplifiers are muted while the fan remains on high speed. If this happens repeatedly, either reduce the load on the amplifier 

(detach one of the speakers), or supply additional cooling to the amplifier, such as a fan. When rack mounting, it is helpful to 
leave 1 RU open above and below the amplifier to prevent heat buildup from adjacent units.

  

POWER SWITCH

 

This heavy-duty, rocker-type switch turns on the mains power to the amplifier. When the mains power is applied, there is a delay 

in activation of the unit. This reduces/eliminates the turn-on transients associated with the system equipment connected to the 

amplifier and protects loudspeakers.

DUAL PRIMARY FUSE

In order to accommodate line voltage switching, the power transformer is designed with two primaries that can be placed in 

series or parallel by means of the line voltage selector switch.  Each primary is individually fused, so there is no need to change 

fuse values when a different line voltage is selected.  It is important to use the fuse values specified on the rear panel. The fuses 

are provided to limit current to the associated transformer primary winding, and protect it from overheating and possible 

destruction due to fault conditions in the unit. The trip current values have been carefully chosen to allow reasonable continuous 

power output performance, while still protecting the power transformer. These fuses should not open unless there is a fault in the 

amplifier circuitry that causes excessive mains current draw. However, abnormal conditions such as a short circuit on either or 

both channels, or continuous operation at overload or clipping (especially into 2-ohm loads per channel or 4-ohm bridge load) 

can cause the fuses to open. If this occurs, UNPLUG from the AC POWER source before replacing the fuses, after waiting a brief 

period of time to allow the unit to cool down. Efforts should be made to correct the cause of the overload, first by disconnecting 

one output at a time, and then one speaker at a time until the bad cable or damaged speaker is isolated. If the fuses open 

instantly each time you attempt to turn the unit on, it should be taken to a qualified Peavey Service Center for repair.

8

THERMAL

PROTECT

PWR

6

16

20

23

26

29

32

6

16

20

23

26

29

32

SIG

DDT

TM

TM

DDT

SIG

PWR

1

2

3

4

5

6

Front Panel

1

6

2

3

4

5

7

Содержание PV 1

Страница 1: ...THERMAL PROTECT PWR 6 16 20 23 26 29 32 6 16 20 23 26 29 32 SIG DDTTM TM DDT SIG PWR THERMAL PROTECT PWR 6 16 20 23 26 29 32 6 16 20 23 26 29 32 SIG DDTTM TM DDT SIG PWR THERMAL PROTECT PWR 6 16 20 23 26 29 32 6 16 20 23 26 29 32 SIG DDTTM TM DDT SIG PWR ...

Страница 2: ...RS phone jack connector THRU LOW out and HIGH out TRS jacks and activation switches for the LOW CUT filter and crossover 150 Hz XOVER Channel output sections feature dual shock proof binding posts and four conductor twist lock connectors An additional four conductor twist lock connector allows BRIDGE mode output UNPACKING Inspect the amplifier during unpacking If any damage is found notify your de...

Страница 3: ...it is helpful to leave 1 RU open above and below the amplifier to prevent heat buildup from adjacent units POWER SWITCH This heavy duty rocker type switch turns on the mains power to the amplifier When the mains power is applied there is a delay in activation of the unit This reduces eliminates the turn on transients associated with the system equipment connected to the amplifier and protects loud...

Страница 4: ...ea before turning the amplifier on for the first time BINDING POST OUTPUTS Shockproof binding post speaker outputs are provided on the PV amplifier For each channel the outputs are in parallel and the speaker connection cables can be terminated with banana plugs or stripped wires for use in the binding post terminals or can be connected using the twist lock outputs 11 For sustained high power appl...

Страница 5: ...ound It is important to realize that the XLR 1 4 jack and barrier strip inputs are all in parallel therefore a balanced input to the associated channel can be accomplished using a male XLR a 3 conductor phone jack or bare wires connected to the barrier strip As an alternative the 1 4 input can also be used with a regular tip sleeve 2 conductor type plug commonly found on single conductor shielded ...

Страница 6: ...y steps to provide adequate cooling The PV Series should never be operated in a fully enclosed cabinet BRIDGE MODE When a 2 channel amplifier is operated in the Bridge mode it is converted into a single channel unit with a power rating equal to the sum of the power rating for each channel at a load of twice that of the single channel rating For example the PV 2 is rated at 750 Watts RMS per channe...

Страница 7: ... to 35 kHz DAMPING FACTOR Typical value Stereo mode both channels driven 8 Ohms 20 Hz 2 kHz 250 1 POWER CONSUMPTION Stereo mode both channels driven 1 8 rated output power 4 Ohms 450W 680W 600W TOPOLOGY Class AB Class AB Class G WEIGHT 40 lbs 18 2 kg 45 lbs 20 5 kg 49 lbs 22 3 kg FEATURE SET All Models indicates each channel DDT COMPRESSION Automatic switchable with LED indicator COOLING SYSTEM Tw...

Страница 8: ...13 T 9 1 2 T 9 1 2 ...

Страница 9: ...14 ...

Страница 10: ...ed only to equipment manufactured after 13 August 2005 www peavey com Warranty registration and information for U S customers available online at www peavey com warranty or use the QR tag below Features and specifications subject to change without notice Peavey Electronics Corporation 5022 Hartley Peavey Drive Meridian MS 39305 601 483 5365 FAX 601 486 1278 ...

Отзывы: