background image

15

IMPORTANT SAFETY INSTRUCTIONS

WARNING: When using electric products, basic cautions should always be followed, including the following.

1.

Read all safety and operating instructions before using this product.

2.

All safety and operating instructions should be retained for future reference.

3.

Obey all cautions in the operating instructions and on the back of the unit.

4.

All operating instructions should be followed.

5.

This product should not be used near water, i.e., a bathtub, sink, swimming pool, wet basement, etc.

6.

This product should be located so that its position does not interfere with its proper ventilation. It should not be placed flat against a
wall or placed in a built-in enclosure that will impede the flow of cooling air.

7.

This product should not be placed near a source of heat such as a stove, radiator, or another heat producing amplifier.

8.

Connect only to a power supply of the type marked on the unit adjacent to the power supply cord.

9.

Never break off the ground pin on the power supply cord. For more information on grounding, write for our free booklet “Shock
Hazard and Grounding.”

10.

Power supply cords should always be handled carefully. Never walk or place equipment on power supply cords. Periodically check
cords for cuts or signs of stress, especially at the plug and the point where the cord exits the unit.

11.

The power supply cord should be unplugged when the unit is to be unused for long periods of time.

12.

If this product is to be mounted in an equipment rack, rear support should be provided.

13.

Metal parts can be cleaned with a damp rag. The vinyl covering used on some units can be cleaned with a damp rag or an ammonia-
based household cleaner if necessary. Disconnect unit from power supply before cleaning.

14.

Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation holes or any other
openings.

15.

This unit should be checked by a qualified service technician if:
a.

The power supply cord or plug has been damaged.

b.

Anything has fallen or been spilled into the unit.

c.

The unit does not operate correctly.

d.

The unit has been dropped or the enclosure damaged.

16.

The user should not attempt to service this equipment. All service work should be done by a qualified service technician.

17.

This product should be used only with a cart or stand that is recommended by Peavey Electronics.

18.

Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in susceptibility to noise
induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time.
The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the following permissible noise level
exposures.

Duration Per Day In Hours

Sound Level dBA, Slow Response

8

90

6

92

4

95

3

97

2

100

1 1/2

102

1

105

1/2

110

1/4 or less

115

According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss.
Ear plugs or protectors in the ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent
hearing loss if exposure is in excess of the limits as set forth above. To ensure against potentially dangerous exposure to high sound pressure
levels, it is recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification
system be protected by hearing protectors while this unit is in operation.

SAVE THESE INSTRUCTIONS!

Содержание IRM 8150

Страница 1: ...1 IRM 8150 Powered Mixer ...

Страница 2: ...d computer controlled all faults analyzed and corrected Q A procedures Each channel features front panel main and monitor level controls as well as high mid low equalization and AUX send controls Every input channel has a studio quality low imped ance XLR type input microphone input as well as a 1 4 line input Switchable 48 V phantom power is provided The unit features a 150 watt power amplifier I...

Страница 3: ...rols the amount of signal from a particular channel in the monitor mix This signal is routed to the Mon control in the master section LOW EQ 3 Controls the channel low EQ level An active tone control shelving type 12 dB that varies the low frequency range MID EQ 4 Controls the channel mid EQ level An active tone control peak notch 12 dB that adjusts the mid frequency range HIGH EQ 5 Controls the c...

Страница 4: ...vel of the main system The signal from this control is available at the main output 20 Under normal conditions this signal is also internally patched through the graphic EQ and power amplifier so that this control sets the volume of the speakers connected to the output barrier strip 30 Maximum master signal level is obtained by rotating this control fully clockwise Minimum master signal level cut ...

Страница 5: ... in jack which can affect the operational level or sonic quality of the system and cause feedback TAPE IN RCA TYPE JACKS 15 These two jacks provide a paralleled input for proper mono mixing of stereo tape deck outputs For monaural tape sources use either jack TAPE OUT RCA TYPE JACKS 16 These two jacks provide the same monaural signal to be supplied to the left and right inputs of a stereo tape dec...

Страница 6: ...s output can also be used for other purposes if external effects are not required These include building a separate mix for recording or broadcasting GRAPHIC INPUT 23 This 1 4 jack provides an input to the internal graphic equalizer power amp This is a switching jack a signal inserted here interrupts the normal signal path from the main bus into the equalizer OPERATION NOTE This jack permits the e...

Страница 7: ... exist when the unit is operated with the proper grounded receptacles OUTPUT BARRIER STRIP 30 Provided for connection of external speakers Power output is 150 watts RMS This is available as a direct output from the power amplifier or as transformer isolated outputs Transformer outputs can be used for an 8 ohm 35 V loudspeaker or used to drive 25 V or 70 V speaker systems Only one output should be ...

Страница 8: ... flat 2 dB Mid EQ 12 dB 600 Hz minimum center detent flat 2 dB Low EQ 12 dB 50 Hz minimum Center detent flat 2 dB Nominal Channel Gain Low Z 20 dB Line 0 dB Minimum Channel Gain Low Z 69 dB Line 89 dB Maximum Channel Gain Low Z 40 dB Line 20 dB Nominal Input Level Low Z 20 dBV Line 0 dBV Minimum Input Level Low Z 40 dBV Line 20 dBV Maximum Input Level Low Z 6 dB Line 26 dB Phantom Power 48 V DC GR...

Страница 9: ... dBV Tape Input Level Nom 4 dBV Max 11 dBV Min 10 dBV POWER AMP SECTION Frequency Response 0 1 dB 20 Hz to 20 kHz Rated Power direct out 0 1 dB 50 Hz to 20 kHz Rated Power XFMR outputs Rated Power Direct Out 150 watts RMS 4 ohms XFMR Outputs 150 watts RMS 8 ohms 150 watts RMS 25 V 4 ohms 150 watts RMS 70 V 33 ohms 1 V RMS into 600 ohms Intermodulation Distortion Less than 0 1 10 mW to rated power ...

Страница 10: ...r Transformer Output to 8Ω Speaker Note Jumper must be in place COM 8 Ω 25V 70V NC 8 Ω HI XFMR 4 Ω GND LO Balanced 600Ω Jumper Installed XFMR 4 Ω GND LO Balanced 600Ω Jumper Installed HI To Booster Amplifier etc Balanced Output Connection Note Jumper must be in place ...

Страница 11: ...11 XFMR 4 Ω GND LO HI Balanced 600Ω 8 Ω Direct Output to Multiple Speakers in Parallel Total Impedance 4Ω 8 Ω ...

Страница 12: ...12 ...

Страница 13: ...EADROOM MAIN MONITOR TAPE AUX 18 dBV NOMINAL AUX INPUT LEVEL 0 dBV NOMINAL FLAT CHANNEL EQ 12 dBV CUT 12 dBV BOOST 600 Hz MAIN MON TAPE AUX OUTPUTS 18 dBV MAXIMUM GRAPHIC INPUT OUTPUT LEVELS 19 dBV MAXIMUM GRAPHIC INPUT OUTPUT LEVELS 0 dBV NOMINAL FLAT GRAPHIC EQ 12 dBV 6 dBV AUX INPUT LEVEL 7 dBV MAXIMUM AUX INPUT LEVEL 15 dBV MINIMUM TAPE INPUT LEVEL 11 dBV MAXIMUM TAPE INPUT LEVEL 4 dBV NOMINAL...

Страница 14: ...RRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE UNDER NO CIRCUMSTANCES WILL PEAVEY BE LIABLE FOR ANY LOST PROFITS LOST SAVINGS INCIDENTAL DAMAGES OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT EVEN IF PEAVEY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE THIS LIMITED WARRANTY IS THE ONLY EXPRESSED WARRANTY ON THIS PRODUCT AND NO OTHER STATEMENT REP...

Страница 15: ...old cleaner if necessary Disconnect unit from power supply before cleaning 14 Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation holes or any other openings 15 This unit should be checked by a qualified service technician if a The power supply cord or plug has been damaged b Anything has fallen or been spilled into the unit c The unit...

Страница 16: ...ations subject to change without notice A Division of Peavey Electronics Corporation 711 A Street Meridian MS 39302 2898 U S A 601 483 5376 Telex 504115 Fax 486 1278 1994 80302192 Printed in U S A 10 94 ARCHITECTURAL ACOUSTICS ...

Отзывы: