background image

FCC/ICES

 

Compliancy

 

Statement

 

This

 

device

 

complies

 

with

 

Part

 

15

 

of

 

the

 

FCC

 

rules

 

and

 

Industry

 

Canada

 

license

exempt

 

RSS

 

Standard(s).

  

Operation

 

is

 

subject

 

to

 

the

 

following

 

two

 

conditions:

 

(1)

 

this

 

device

 

may

 

not

 

cause

 

harmful

 

interference,

 

and

 

(2)

 

this

 

device

 

must

 

accept

 

any

 

interference

 

received,

 

that

 

may

 

cause

 

undesired

 

operation.

 

Le

 

présent

 

appareil

 

est

 

conforme

 

aux

 

CNR

 

d’lndustrie

 

Canada

 

applicables

 

aux

 

appareils

 

radio

 

exempts

 

de

 

licence.

  

L’exploitation

 

est

 

autorisée

 

aux

 

deux

 

conditions

 

suivantes:

 

(1)

 

I’appareil

 

ne

 

doit

 

pas

 

produire

 

de

 

brouillage,

 

et

 

(2)

 

I’utilisateur

 

de

 

I’appareil

 

doit

 

accepter

 

tout

 

brouillage

 

radioélectrique

 

subi,

 

même

 

si

 

le

 

brouillage

 

est

 

susceptible

 

d’en

 

compromettre

 

le

 

fonctionnement.

 

Warning:

 

Changes

 

or

 

modifications

 

to

 

the

 

equipment

 

not

 

approved

 

by

 

Peavey

 

Electronics

 

Corp.

 

can

 

void

 

the

 

user’s

 

authority

 

to

 

use

 

the

 

equipment.

 

Note

 

 

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

a

 

Class

 

B

 

digital

 

device,

 

pursuant

 

to

 

Part

 

15

 

of

 

the

 

FCC

 

Rules.

  

These

 

limits

 

are

 

designed

 

to

 

provide

 

reasonable

 

protection

 

against

 

harmful

 

interference

 

in

 

a

 

residential

 

installation.

  

This

 

equipment

 

generates,

 

uses,

 

and

 

can

 

radiate

 

radio

 

frequency

 

energy

 

and,

 

if

 

not

 

installed

 

and

 

used

 

in

 

accordance

 

with

 

the

 

instructions,

 

may

 

cause

 

harmful

 

interference

 

to

 

radio

 

communications.

  

However,

 

there

 

is

 

no

 

guarantee

 

that

 

interference

 

will

 

not

 

occur

 

in

 

a

 

particular

 

installation.

  

If

 

this

 

equipment

 

does

 

cause

 

harmful

 

interference

 

to

 

radio

 

or

 

television

 

reception,

 

which

 

can

 

be

 

determined

 

by

 

turning

 

the

 

equipment

 

off

 

and

 

on,

 

the

 

user

 

is

 

encouraged

 

to

 

try

 

and

 

correct

 

the

 

interference

 

by

 

one

 

or

 

more

 

of

 

the

 

following

 

measures.

 

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.

Consult the dealer or an experienced radio/TV technician for help.

Caution 

The equipment complies with FCC radiation exposure limits set forth for an uncontrolled 
environment. 

Содержание DPE118P

Страница 1: ...www peavey com DPE 118P Compact Vented Powered Subwoofer System Operating Manual ...

Страница 2: ...h the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there...

Страница 3: ...arity switch for polarity reversal of subwoofer Ground lift for disconnecting cable shield from ground Rugged Plywood enclosure with bracing and T nuts Full coverage heavy duty perforated steel grill Steel handles Threaded pole mount with speaker pole included APPLICATIONS The Peavey DPE 118 has a variety of applications such as extending the bass performance of smaller full range speaker systems ...

Страница 4: ...he IEC line cord supplied that provides AC power to the unit It is very important that you ensure the DPE 118 has the proper AC line voltage supplied You can find the proper voltage for your DPE 118 printed next to the IEC line power cord on the rear panel of the unit Please read this guide carefully to ensure your personal safety as well as the safety of your equipment Never break off the ground ...

Страница 5: ...wer amp input INPUT The line level input is of the medium impedance balanced type The jack is a combo female XLR and 1 4 TRS connector GROUND LIFT SWITCH Provided for disconnecting cable shield from chassis ground to break potential ground loops and reduce hum UPPER REAR PANEL 6 4 11 12 7 8 9 5 10 4 6 5 7 8 9 DPE 118P powered by Designed and Engineered in U S A Made in China AC Cable 100 120V 50 6...

Страница 6: ...ide a high pass filtered signal to be fed to a full range powered speaker system Other full range powered speakers can be used and full range passive speakers can be used in conjunction with a suitable power amp to drive them These outputs are electronically buffered and isolated from the input and from each other and their level is not affected by the DPE 118 Level control 8 THRU FULL RANGE OUTPU...

Страница 7: ... capable of SPL in excess of 130 dB at 1 meter distance from the speaker CONNECTING AC POWER TO THE DPE 118P SUB The DPE 118P Sub comes with a 6 foot IEC connection AC power cord If you are using an extension cord or power strip with this powered speaker make sure it is of good quality and of a sufficient current capacity to maintain safety and maximize the power output capability of the DPE 118P ...

Страница 8: ...will not trip over them or tip the speaker over Use of duct tape cable channels or guards or other appropriate tie down cover up devices should be carefully considered and implemented When installing or un installing the speaker on the pole it is a good practice to have a helper if possible as it can be hard to thread the needle and mate the stand cup to the stand pole while holding the DPE 2P spe...

Страница 9: ...r when pole mounted LEVEL CONTROL ADJUSTMENT The DPE 118P Sub is equipped with a Level control 7 on the input channel to facilitate use in many different applications With the Gain control adjusted fully clockwise gain is at maximum and the input sensitivity is 0 100 V RMS for full rated output When driving the DPE 118P Sub from a mixer it may be advantageous to reduce the input sensitivity by tur...

Страница 10: ... e a power amp and speaker If this produces a signal make sure that all Level controls 7 being used have been turned up to a satisfactory level one third to halfway If the DPE 118P Sub has been subjected to direct sunlight or excessive heat the built in thermal protection may have been triggered If so turn off the DPE 118P Sub and let it cool for a sufficient amount of time If there is still no ou...

Страница 11: ...d in or turned on CHECK FOR SECURE HARDWARE After the first few weeks of use and periodically thereafter check the hardware of the DPE 118P Sub for tightness including the amplifier rear panel screws The unit is subject to a great deal of vibration and this could cause them to loosen with use ARCHITECTURAL AND ENGINEERING SPECIFICATIONS THE POWERED SUBWOOFER LOUDSPEAKER SYSTEM SHALL HAVE A FREQUEN...

Страница 12: ... A steel handle shall be incorporated on each side A powder coated metal grille shall be provided for woofer protection The DPE 118P Sub cabinet shall incorporate a threaded pole mounting plate for satellite speaker deployment with a supplied 1 3 8 diameter threaded steel pole and four sturdy rubber feet for floor standing use The outside dimensions shall be 26 38 67 0 cm tall x 22 88 58 1 cm wide...

Страница 13: ...d One Full Range Thru electrically buffered Electronic Input Impedance Nominal Line In 2 2 k ohms balanced XLR or 1 4 10 k ohms unbalanced 1 4 Controls Level Control Provides gain adjustment Crossover Frequency Adjust Adjusts electrical crossover frequency from 90 Hz to 180 Hz continuously variable Polarity Switch Provides either 0 degrees or 180 degrees sub woofer phase Ground Lift Switch for inp...

Страница 14: ...NOTES ...

Страница 15: ...NOTES ...

Страница 16: ...ed only to equipment manufactured after 13 August 2005 www peavey com Warranty registration and information for U S customers available online at www peavey com warranty or use the QR tag below Features and specifications subject to change without notice Peavey Electronics Corporation 5022 Hartley Peavey Drive Meridian MS 39305 601 483 5365 FAX 601 486 1278 ...

Отзывы: