Peavey 6505 212 Combo Скачать руководство пользователя страница 9

F

F

U

U

S

S

E

E

9

Equalization (8, 9, 10) 

The 6505 212’s equalization block features passive LOW, MID and HIGH EQ that is custom tailored to 
the 6505 sound.

Resonance & Presence (13, 14) 

Unique to the 6505, the RESONANCE [13] control can be set to boost the gain of the power amp in 
the low frequencies at the resonance/attenuation point of the speaker cabinet. In simple terms, 
the RESONANCE control works like a low EQ to offset low-end frequency drop-out. The PRESENCE 
[14] control works in the same manner, boosting the high frequencies. Experimentation using your 
particular speaker cabinet along with personal taste will determine your setting for these important 
controls.

Standby Switch (15) 

This switch allows the 6505 to be placed in a non-operational standby mode. When the standby switch 
is activated, the tubes remain hot and ready for instantaneous operation, eliminating warm-up time. 
The STANDBY LED indicator light will illuminate when the amp is in the operational mode.

Power Switch (16) 

This switch supplies power to the unit. Depressed to the “on” position, the POWER LED indicator light 
will illuminate, indicating power is being supplied to the unit.

Fuse (17) 

A 3 amp fuse is located within the cap of the fuse holder. It must be replaced with the same type 
and value in order to avoid damage to the equipment and to prevent voiding the warranty. If the amp 
repeatedly blows fuses, it should be taken to a qualified service center for repair.

WARNING

: The fuse should only be replaced when the power cord has been disconnected from 

its power source.

Top Panel

8

9

10

13

14

15

16

17

Содержание 6505 212 Combo

Страница 1: ...For information on other great Peavey products go to your local Peavey dealer or visit us online at www peavey com Tube Guitar Amplifier Owner s Manual 6505 212 Combo...

Страница 2: ...est utilis dans ce manuel pour indiquer l utilisateur la pr sence d une tension dangereuse pouvant tre d amplitude suffisante pour constituer un risque de choc lectrique Ce symbole est utilis dans ce...

Страница 3: ...ver break off the ground pin Write for our free booklet Shock Hazard and Grounding Connect only to a power supply of the type marked on the unit adjacent to the power supply cord 16 If this product is...

Страница 4: ...enst nde in das Ger t gelangt sind das Ger t Regen oder Feuchtigkeit ausgesetzt wurde nicht normal arbeitet oder heruntergefallen ist 15 Der Erdungsstift darf nie entfernt werden Auf Wunsch senden wir...

Страница 5: ...unit 16 Si votre unit est destin e a etre mont e en rack des supports arriere doivent etre utilises 17 Note pour les Royaumes Unis Si les couleurs de connecteurs du cable d alimentation ne correspond...

Страница 6: ...Escr banos para obtener nuestro folleto gratuito Shock Hazard and Grounding Peligro de Electrocuci n y Toma a Tierra Conecte el aparato s lo a una fuente de alimentaci n del tipo marcado al lado del...

Страница 7: ...versatility than its stacked stable mate thanks to an enhanced clean sound and circuitry that takes full advantage of the cabinet s sonic possibilities and the impressive tonal balance of well matched...

Страница 8: ...channel PRE 4 and POST GAIN 11 operate in the same manner as the LEAD channel gain controls For most applications the RHYTHM channel should be set up with the PRE GAIN at the lower cleaner settings 0...

Страница 9: ...switch allows the 6505 to be placed in a non operational standby mode When the standby switch is activated the tubes remain hot and ready for instantaneous operation eliminating warm up time The STAN...

Страница 10: ...h jack the Channel Select switch 3 must be pressed to the in position for remote selection of the LEAD or RHYTHM channel left footswitch button or On and Off operation of Reverb right footswitch butto...

Страница 11: ...he rear of the unit to the impedance that matches your enclosure When two enclosures of equal impedance are used set the switch to one half the impedance of one enclosure e g for two 16 ohm enclosures...

Страница 12: ...0 watts 50 60 Hz 120 V AC Domestic Preamp Section The following specs are measured 1 kHz with the controls preset as follows Low High EQ 10 Mid EQ 0 Bright out Lead Rhythm Posts 10 Presence Resonance...

Страница 13: ...ms or greater Nominal Output 10 dBV 3 V RMS Remote Footswitch Special 2 button unit with LED indicators supplied Channel select reverb System Hum Noise Nominal Level Clean channel 20 Hz to 20 kHz unwe...

Страница 14: ...14 Notes...

Страница 15: ...ill pay the return shipping charges How To Get Warranty Service 1 Take the defective item and your sales receipt or other proof of date of purchase to your Authorized Peavey Dealer or Authorized Peave...

Страница 16: ...Features and specifications subject to change without notice Peavey Electronics Corporation 711 A Street Meridian MS 39301 601 483 5365 FAX 601 486 1278 www peavey com 80303146 2005...

Отзывы: