Use only copper wire to motor and ground. The ground wire 

MUST be at least as large as the wire to the motor.

Wires should be color coded for ease of maintenance.

Compare the frequency and mains voltage with the name-plate 

data and connect the supply conductors to the terminals in  

accordance with the appropriate diagram inside the terminal box 

cover.

ATTENTION: never allow washers or other metal parts to fall into 

the internal cable opening between the terminal box and stator. 

If this occurs, dismantle the motor to recover the object which 

has fallen inside.

If the terminal box is provided with an inlet gland, use a flexible 

power supply cord of the H07 RN-F type with section of cable not 

less than 11 TAB IEC 60335-1.

If the terminal box is provided with an inlet bushing, connect the 

power supply cord through a conduit.

For use in swimming pools (not when persons are in the pool), 

garden ponds and similar places, a residual current device with 

I

Δ

N not exceeding 30 mA must be installed in the supply circuit.

Install a device for disconnection from the mains (switch) with a 

contact separation of at least 0,12 inch in all poles.

With a three-phase motor install an overload protection device 

with curve D appropriate for the rated current of the pump.

Single-phase, are supplied with a capacitor connected to the  

terminals with an incorporated thermal protector.

ATTENTION: When the pump is fed by a frequency 

converter, the minimum frequency should not fall  

below 25Hz and in any case the total head of the pump 

should never be lower than 10 ft.

7. STARTUP AND OPERATION

7.1. Preliminary checks before start-up of the pump

Do not start-up the device in case of damaged parts.

7.2. First starting

ATTENTION: never run the pump dry. Start the pump after filling 

it completely with liquid.

When the pump is located above the water level (suction lift  

operation par. 13 fig. 2) or with a positive suction head which 

is too low (less than 33 ft) to open the non-return valve, fill the 

pump through the priming hole (par. 13 fig. 4).

When the liquid level on the suction side is above the pump (in-

flow under positive suction head part. 13

fig. 1), fill the pump by opening the suction gate valve slowly 

and completely, keeping the delivery gate valve open to release 

the air.

Before starting, check that the shaft turns by hand. For this  

purpose use the screwdriver notch on the shaft end on the  

ventilation side.

When starting, with a three-phase motor, check that the direction 

of rotation is as shown by the arrows on the lantern bracket.

Otherwise, disconnect electrical power and reverse the 

 

connections of two phases.

Check that the pump works within its field of perfor-mance and 

that the absorbed current

shown on the name-plate is not exceeded. Otherwise adjust the 

delivery gate valve or the setting of any pressure switches.

If a priming loss occurs (interruption of delivery flow)

or if a pressure oscillation is indicated by the pressure gauge, 

make sure all the suction pipe couplings are perfectly sealed and 

tighten the two sealed plugs on the pump casing.

Never run the pump for more than five minutes with a 

closed gate valve.

Prolonged operation without a change of water in the pump 

causes dangerous increases of temperature and pressure.

When the water is overheated due to prolonged operation with a 

closed port, stop the pump before opening the gate valve.

To avoid any risk of danger to users and the creation of harmful 

thermal stress in the pump and system due to large temperature 

differentials, wait until the water has cooled inside the pump  

before starting again.

If the water is overheated on account of prolonged operation with 

a non-primed or insufficiently filled pump (suction lift operation), 

wait until cool before opening the draining and filling plugs.

Care must be taken when the pumped fluid has a high  

temperature. Do not touch the fluid when its tem-

perature is higher than 140 °F. Do not touch the pump 

when the surface temperature is higher than 176 °F.

7.3. Self-priming

(Capability to clear the air in the suction pipe when starting with 

the pump located above the water level).

Conditions for self-priming:

• suction pipe with connections perfectly airtight and properly 

immersed in the water to be lifted;

• discharge pipe with a straight vertical free line above discharge 

port 

16,5 ft (

33 ft for JCCQ15, JCCH 15, JCCH 20), before a 

non-return valve (par. 13 fig. 6).

• pump casing completely filled with clean cold water berfore 

starting.

The pump is not self-priming with liquids containing oil, alcohol 

or foaming substances.

The check valve prevents reverse siphoning through the pump 

when the pump is stopped and retains water in the pump for 

the next start.

Without a foot valve or a check valve on the suction connection 

the filling operation must be repeated before each start-up.

ATTENTION: avoid a prolonged operation with 

unprimed pump, without water delivery from the com-

pletely opened outlet. If the pump does not prime in 5 

minutes: stop the motor, remove the priming plug and 

add more water.

If necessary, repeat the priming operation after the pump has 

been first emptied and then completely filled with clean cold 

water.

7.4. Gate valve regulation

With the gate valve completely open or with an outlet pressure 

lower than the minimum pressure shown on the name-plate, the 

pump may be noisy. To reduce noise regulate the delivery gate 

valve.

7.5. Switch off of the pump

The appliance must be switch off every time there are 

faults. (see troubleshooting).

The product is designed for a continuous duty, the switch off 

is performed by disconnecting the power supply by means the  