Always use the pressure regulator and hose assembly provided with the appliance to connect to a LP gas
cylinder. Never connect to an unregulated LP gas supply.
Contact your retailer’s customer service department for replacement parts.
Hand turn the manual gas control valve. Never use tools. If the valve will not turn by hand, do not try to repair
it. Call a certified gas technician. The use of force or any self attempted repair may result in a fire or explosion.
Use only the type of gas and the type of LPG cylinder specified by the manufacturer.
Appliance is fitted with gas regulator, flexible gas rubber pipe and clamps according to the National Rules in
force of the country of destination.
Appliance must use an approved gas regulator (approved for a working temperature not lower than 50 ˚C)
according to the EN Standard (see minimum, nominal and maximum pressure on page 11 - gas regulator
inlet and outlet connection according to the National Rules in force) and flexible gas rubber pipe according to
EN 16436-1 (with proper inner diameter according to gas inlet connection and National Rules in force) with a
length not over 3.0 m and approved for a working temperature not lower than 60 ˚C. When substitution will be
necessary, you have to purchase suitable gas regulator, flexible gas rubber pipe and clamps from your local
gas dealer; gas regulator should be substituted not over 10 years.
Flexible gas rubber pipe must be carefully , avoiding any twisting. Never use a damaged gas regulator.
Never connect this appliance to an unregulated LPG source (gas regulator is mandatory to be used).
When the appliance is not in use, turn the LPG cylinder in “OFF” position.
Always perform a leakage test on gas connections whenever a LPG cylinder is connected. If bubbles form in
Flexible gas rubber pipe must be located in the LPG compartment carefully, avoiding any twisting.
Never use a damaged gas regulator.
Always perform a leakage test on gas connections whenever a LPG cylinder is connected. If bubbles form in
the leakage test solution, do not use it. Never use a flame to test for leakages.
It is strictly forbidden and
dangerous!
to change the gas cylinder in a amply ventilated area, away from any ignition source.
The tanker is away form the fireplace 60 inch.(see below picture).