39
Marker->
Set the other system parameters (such as frequency, Reference level) using the
current marker reading. Press
Marker ->
to enable a marker if none of them are
active at present.
Mkr->CF
Set the center frequency of analyzer to be the frequency of current marker.
If Normal is selected, the center frequency will be set to the frequency of current
marker.
If Delta, Delta Pair, or Span Pair is selected, the center frequency will be set to the
frequency where Delta Marker is.
In Zero span mode, this function is invalid.
Mkr->Step
Set the CF step of analyzer to be the frequency of current valid marker.
If Normal is selected, the CF step will be set to the frequency of current marker.
If Delta, Delta Pair, or Span Pair is selected, the CF step will be set to the frequency
where Delta Marker is.
In Zero span mode, this function is invalid.
Mkr->Start
Set the start frequency of analyzer to be the frequency of current valid marker.
If Normal is selected, the start frequency will be set to the frequency of current
marker.
If Delta, Delta Pair, or Span Pair is selected, the start frequency will be set to the
frequency where Delta Marker is.
In Zero span mode, this function is invalid.
Mkr->Stop
Set the stop frequency of analyzer to be the frequency of current valid marker.
If Normal is selected, the stop frequency will be set to the frequency of current
marker.
If Delta, Delta Pair, or Span Pair is selected, the stop frequency will be set to the
frequency where Delta Marker is.
In Zero span mode, this function is invalid.
Marker
Δ->Span
Set the span of analyzer to be the difference between the two markers in type of of
Delta, Delta Pair or Span Pair. In Zero span mode, this function is invalid.
Mkr->Ref
Set the reference level of analyzer to be the amplitude of current valid marker.
If Normal is selected, the reference level will be set to the amplitude of current
marker.
If Delta, Delta Pair, or Span Pair is selected, the reference level will be set to the
amplitude where Delta Marker is.