47
LCD display -010.0V appears. If reference value and
measured value are the same, the digital display shows the
value of "0."
Press and hold the REL / RS-232 button briefly, the data
interface is activated and an RS-232 symbol is shown on
the display. The device cannot transmit any measurement
data without an activated interface.
8. Rotary Seletor
This function selector switch is used to switch between the
different measurement functions. To select the desired
measurement function, turn the switch to the appropriate
position.
9. 10A Input Jack
The 10A jack is used for AC and DC currents up to 10A up
with measurement up to 10 seconds once every 15 minutes.
Connect the red lead for current measurements with this
jack. This range is protected by a 10A fuse against
overload.
10. V/
/Hz/
/ /CAP/TEMP Input Jack
To connect the red test lead for voltage, resistance,
capacitance and frequency measurements, as well as for
the measurement functions diode and continuity tests.
11. mA Input Jack
The mA jack is used for AC and DC currents up to 400mA,
and the temperature measurement. Connect mA current
measurements with the red lead to this terminal and for
temperature measurement the connector of the temperature
sensor / adapter. This range is protected by a 600mA fuse
against overload.
12. COM Input Jack
To connect the black test lead (all measurement functions).