Data Logging
Initialization duration of the
data logger firmware
50 ms (wake-up duration not included)
Recording format
Proprietary binary format (*.btrc),
Conversion options with the supplied
Windows program:
- PCAN-Trace (*.trc)
- Vector trace (*.asc)
- comma separated values (*.csv)
Environment
Operating temperature
-40 - 85 °C (-40 - 185 °F)
Temperature for storage
and transport
-40 - 100 °C (-40 - 212 °F)
Relative Humidity
15 - 90 %, non-condensing
Protection class (IEC 60529) IP20
Measures
Size
190 x 104 x 55 mm
(see also Dimension Drawing on page 50)
Weight (without battery and
optional interface)
696 g
Weight with optional
interface (without battery)
720 g
Conformity
EMV
EU Directive 2014/30/EU
DIN EN 61326-1:2013-07; VDE 0843-20-1:2013-07
RoHS 2
EU Directive 2011/65/EU (RoHS 2)
EU Directive 2015/863/EU (amended list of restricted
substances)
DIN EN IEC 63000:2019-05;VDE 0042-12:2019-05
4
The operating temperature as well as the temperature for storage and transport
can be limited by installing a backup battery.