PCAN-MiniDisplay – User Manual
28
Do the following to record:
1.
Make sure that there is no USB connection between the
PCAN-MiniDisplay and your PC.
2.
Click on
Start
.
The recording is saved to the indicated
File
.
3.
End the recording with
Stop tracing
.
Indication
Meaning
File
Name of the trace file of the current recording. The file
name (
trc00000.btr
) is automatically put together
with a consecutive number. When recording in
multiple files, another two-digit index is added.
Start time
Specifies the start time of the recording.
CAN queue level in %
Current and maximum fill level of the receive queue
(latter in parentheses). If the queue has reached a fill
level of 100 percent, most likely some incoming CAN
messages were not recorded.
CAN messages total
Number of CAN messages that have been recorded.
File size
Current size of the trace file in kByte and already used
storage space relative to the maximum possible file
size.
During recording, the trace file grows in 512-byte
blocks, each containing 25 CAN messages. Thus,
1 MByte can hold 51200 CAN messages.
File count
Number of files recorded. When the recording is done
with
Trace type
circular
, the number is
incremented linearly regardless of the current file
index.
Trace type
Indicates the used trace type.
Session type
Indicates the used session type.