Installation and Operating Handbook
4.2.2.1
Instruction 24 (Remote / Local Change Request)
Table 4.7: Remote / Local Change Request message format (instruction 24)
Message
byte no.
Set value / example
Length
(bytes)
Description
1
02
1
STX
2
7
1
Number of bytes
3
32
1
Unit address
4
24
1
Instruction number
5
'R'
1
Remote / local mode
’R’ = Remote
’L’ = Local
6
?
1
Checksum
7
03
1
ETX
14
Peak Communications Ltd.
PBU2000