VIII.TROUBLE SHOOTING

NO

TROUBLE

CAUSE

REMEDY

1

Motor does not run

1. Button does not work

1. Replace button

2. Wiring connections are not

in good condition

2. Repair all wiring connections

3. Motor burned out

3. Repair or replace motor

4. AC contactor burned out

4. Replace AC Contactor

2

Motor runs but the lift

is not raised

1. Motor runs in reverse
rotation

1.Reverse two power wire

2. Release Valve in damage

2. Repair or replace

3. Gear Pump out of operation 3. Repair or replace
4. Relief Valve or Check Valve

in damage

4. Repair or replace

5. Low oil level

5. Fill tank

6. Overload lifting or low

pressure

6.Check load or adjust the pressure

3

Lift does not stay

up

1. Release Valve out of work

Repair or replace

2. Relief Valve or Check Valve

leakage

Repair or replace

3. Cylinder or Fittings leaks

Replace fitting and oil seal

4

Lift rises slowly

1. Oil line is jammed

1. Clean the oil line

2.Motor

running

on

low

voltage

2. Check Electrical System

3. Oil mixed with air

3. Fill tank

4. Gear Pump leaks

4. Repair or replace

5. Overload lifting

5. Check load

5

Lift cannot lower

1. Safety device are not in
activated

1. Release the safety device

2. Release Valve in damage

2. Repair or replace

3. Oil system is jammed

3. Clean the oil system

Содержание MC-600H

Страница 1: ...Motorcycle lift MC 600H...

Страница 2: ...Features and Specifications 2 II Installation requirement 3 III Steps of Installation 4 IV Exploded View 9 V Test Run 12 VI Operation Instruction 13 VII Maintenance 14 VIII Trouble shooting 15 IX MC...

Страница 3: ...f lubricating UHMW Polyethylene sliders and bronze bush Non skid diamond platforms Automatic safety release system Optional Width extension kit and platform extension kit MODEL MC 600H SPECIFICATION M...

Страница 4: ...2 II INSTALLATION REQUIREMENT A TOOLS REQUIRED Rotary Hammer Drill 19 Ratchet Spanner with Socket 28 Screw English Spanner 12 Wrench Set 13 15 17 19 Fig 2 F Pliers Grease gun Hook Spanner 40 42mm...

Страница 5: ...stallation 2 Concrete must be of test strength 210kg cm2 minimum C POWER SUPPLY The power capacity must be more than 2 2kw The source cable size must be 2 5mm and in good condition of contacting with...

Страница 6: ...cording to the parts list See Fig 4 3 Open the parts bag check the parts according to the parts list See Fig 5 B Put the lift and control cabinet in good order and connect the oil hose see Fig 6 Fig 4...

Страница 7: ...hose fittings fill the power unit with right amount hydraulic oil in order to ensure the working life of hydraulic system and the machine reach the best performance please fill in the no 46 high quali...

Страница 8: ...ft to a suitable height install the adjustable fixing device according to below photo 2 The adjustable fixing device can be chosen to install in different installed position of the platform F Install...

Страница 9: ...ension kit optional See Fig 11 Note Connect the holes on platform extension kit and the platform Install the adjustable fixing device on the platform extension kit IV EXPLODED VIEW 58 59 60 61 62 Fig...

Страница 10: ...8 MODEL MC 600H Fig 12...

Страница 11: ...9 Control Cabinet Cylinder Fig 14 Fig 13...

Страница 12: ...ic power unit 220V 60Hz 1 phase Handle of Release valve Release valve Throttle valve Oil Outlet Oil return port Protective ring Fig 17 PEAK ELECTRIC POWER UNIT 220V 60Hz 1 phase Fig 15 PEAK ELECTRIC P...

Страница 13: ...lock handle as the direction of arrow Loosen the screw of the safety cable by spanner lift up the safety lock plate from the rack about 15 20mm See Fig 20 then tighten the safety cable by spanner Step...

Страница 14: ...t well the motorcycle Put up the foot stool of vehicle Clamp the tire by the rotated handle Tighten the Tension bandage Make sure the wheel is tightened and the Tension bandage is fixed before using S...

Страница 15: ...2 Check all connectors bolts and pins to insure proper mounting 3 Make a visual inspection of all hydraulic hoses lines for possible wear or leakage Every six months 1 Make a visual inspection of all...

Страница 16: ...damage 4 Repair or replace 5 Low oil level 5 Fill tank 6 Overload lifting or low pressure 6 Check load or adjust the pressure 3 Lift does not stay up 1 Release Valve out of work Repair or replace 2 Re...

Страница 17: ...Self locking nut 2 14 203004A Bronze bush 8 15 720007 Pin for Scissor 2 16 720003 Spring 4 17 720012 Pin for Spring 4 18 209025 Pin 6 19 640006A Cylinder Base Pin 25 1 20 640007 Cylinder 1 21 640057 P...

Страница 18: ...justable frame 1 51 420244 Transition Fitting 1 51 1 420245 Exchange Fitting 1 51 2 420119 Straight fitting 1 52 206156 tool tray 1 53 720079A Control cabinet electric 1 54 620071 Anchor bolt 4 55 720...

Страница 19: ...Nut 1 20 14 620064 Oil nozzle 2 Parts for Control cabinet Item Part Description QTY Note 53 1 720052 Control panel 1 53 2 61K077 Light white 1 53 3 420071 Button UP 2 53 4 209145A Cup head bolt 4 53 5...

Страница 20: ...er 4 200 10 81400148 Socket bolt 4 200 11 81400224 Inlet pipe 1 200 12 81400225 O Ring 1 200 13 81400226 Filter 1 200 14 81400145 Socket bolt 4 200 15 81400227 Reservoir 1 200 16 81400228 Motor termin...

Страница 21: ...4 200A 10 81400148 Socket bolt 4 200A 11 81400224 Inlet pipe 1 200A 12 81400225 O Ring 1 200A 13 81400226 Filter 1 200A 14 81400145 Socket bolt 4 200A 15 81400227 Reservoir 1 200A 16 81400228 Motor t...

Страница 22: ...20 Revised date 2016 12 No Of service manual 72272104...

Отзывы: