background image

Page 23

Go Online or Complete and Return

We know that registering any of your recently purchased products is not the 

first thing on your mind- but it is very important to both of us. Not all warranties 

are alike and Peak Scientific stand out against other gas suppliers as we offer 
a comprehensive on-site warranty.  This means that in the very unlikely case 

that your gas generator develops a fault we have rapid support teams on-hand 
throughout the globe who are able to come to your lab and get you back up 
and running in no time.

Register for your 

comprehensive 12 month on-site warranty 

with ease online at 

www.peakscientific.com/protected.

Alternatively, you can send the completed form to Peak Scientific by post or 
email at [email protected].

Important!

You have 

1 month to register

 your Peak Scientific product from the date of 

installation. Once registered the warranty will be honoured for a period of 12 
months. If you wish to defer the installation of your generator, you must notify 
Peak Scientific immediately by emailing 

[email protected]

 For 

generators that remain unregistered after 1 month from the shipment date, the 
warranty will be considered active from the date of factory dispatch.

Go Online or Complete and Return

You can register for your 

FREE 12 month Warranty 

with ease online at 

www.peakscientific/protected

.

Alternatively, you can send the completed form to Peak Scientific by post or 
email at 

[email protected]

.

Product Warranty Registration

Contact name

Email address

Company

Address

City/town

Postcode

Country

Telephone

Generator serial #

Model type

Installation date

Do you still use an 
alternative gas solution i.e. 
cylinders or bulk liquid?

Yes                 No

What gas requirements do 
you have in your lab?

Hydrogen             Nitrogen            Zero Air

Extend your cover with

Peak Scientific offer comprehensive gas generator after sales support packages.  
Peak [Protected] aftercare support can guarantee an on-site response within 
72 hours*, genuine parts from our ISO9001 approved factory and a 95% first-time 
fix rate.  See our enclosed Peak [Protected] leaflet for further information.

Important!

You have 1 month to register your Peak Scientific product from the date of installation. Once registered 

the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your 

generator, you must notify Peak Scientific immediately by emailing [email protected]

For generators that remain unregistered after 1 month from the shipment date, the warranty will be 

considered active from the date of factory dispatch.

* Complete Plan only

Содержание Genius AB-3G

Страница 1: ...GeniusAB 3G Installation Guide Rev 1 PN 3300042 21 12 16 Genius AB 3G Installation Guide...

Страница 2: ...or more extensive user operation directions we recommend you download the User Manual from the website Please visit www peakscientific com downloads to download the full User Manual for your gas gener...

Страница 3: ...CAUTION notice denotes a hazard It calls attention to an operating procedure process or similar which if not correctly performed or adhered to could cause damage to the Generator or the Application D...

Страница 4: ...le C19 04 1025 x1 US Mains Cable C19 6 15 04 1024 x1 EU Mains Cable C19 04 1026 4x3m 1 4 Teflon Tubing 00 1266 x3m 6mm OD x 4mm ID PE 00 1282 x1 8mm Hex Key 00 0007 x3 1 4 Compression Fitting 02 4421...

Страница 5: ...t surface in desired area 1 2 First remove the compressor transit brackets These can be accessed by removing the generator top panel Using a Pozidrive 1 screwdriver turn each screw shown 90 to the rig...

Страница 6: ...g it off the spade connector on the panel 4 Remove the 8 mounting screws circled then lift the transit brackets out starting with the two on the centre compressor Do not discard the transit brackets o...

Страница 7: ...Page 7 6 5 Select the 6mm Push Fit Fitting 02 4600 and attach to the Drain port at the rear of the generator 02 4600 Re attach the top panel Ensuring the earth lead is re connected...

Страница 8: ...lock 90 to the right 00 0007 Connect the 6mm PE Tubing 00 1282 to the 6mm Push Fit Fitting 02 4600 Fit the other end of the tubing to a suitable drain connection or container The container MUST NOT ha...

Страница 9: ...hand side panel ensuring you disconnect the earth lead from the panel 10 9 Select the appropriate mains cable from the fittings kit and plug the IEC 60320 C19 cable into the mains input at the rear of...

Страница 10: ...using the switch on the front panel 230VAC 50 60Hz Plug the mains cable into the corresponding 230VAC 50 60Hz single phase power supply CAUTION ensure the correct cable has been selected for your ele...

Страница 11: ...age that is being supplied to the generator Not the displayed voltage If the voltage is 219V or less we would highly reccomend fitting a transformer This can be ordered directly from Peak 06 3200 Dual...

Страница 12: ...Page 12 14 13 Remove the mains cable completely from the power supply CAUTION Re attach the right side panel to the generator ensuring the earth lead is re connected and the lock is secured...

Страница 13: ...Page 13 16 15 With the side panels securely re attached the mains power supply can be re connected CAUTION Switch the generator ON using the switch on the front panel...

Страница 14: ...tart until the user has pressed the confirm button The unit will now begin an Installation Diagnostics Sequence This will take approx 20 mins to complete PLEASE CONFIRM THAT ALL TRANSIT BRACKETS HAVE...

Страница 15: ...confirm has been pressed Once diagnostics have been completed the unit will take a couple of minutes to be ready for use Please ensure that any tubing connected to the drain port is secure and that th...

Страница 16: ...beeps to signify the unit is ready for use and a reminder to register the unit will be displayed When an option has been selected the unit will display NORMAL OPERATION Peak Scientific AB 3G NORMAL O...

Страница 17: ...19 Leave the generator switched on for a period of 30 minutes to purge the system 30 minutes After 30 minutes of running the generator can be turned OFF Allow the stored gas in the internal tanks to...

Страница 18: ...e fittings can be connected to the generators gas outlets Select the Compression Fittings 02 4421 and connect to the CURTAIN SOURCE EXHAUST ports Attach the Teflon tubing 00 1266 to the fittings attac...

Страница 19: ...ch the generator power ON using the switch on the front panel The unit will now display PLEASE WAIT while sufficient operating pressures are reached This may take up to 20 minutes Peak Scientific AB 3...

Страница 20: ...ssure gauges will again gradually increase to the factory set pressures Once the output and tank pressures are up to operating conditions the unit will display NORMAL OPERATION Peak Scientific AB 3G N...

Страница 21: ...Page 21 25 CONGRATULATIONS Your Peak Scientific gas generator is now fully installed operational and ready to supply gas on demand to your instrument...

Страница 22: ...ument then attention needs to be paid to pressure drops that could occur The maximum distance away from the instrument the generator can be placed still using 6mm 4mm internal diameter or 3 16 interna...

Страница 23: ...e date of factory dispatch Go Online or Complete and Return You can register for your FREE 12 month Warranty with ease online at www peakscientific protected Alternatively you can send the completed f...

Страница 24: ...o download the full User Manual for your gas generator Peak Scientific has highly trained fully certified Field Service Engineers located in over 20 countries across every continent around the world T...

Отзывы: